{"title":"8500 III Hydroflame Parts","description":"\u003cp data-start=\"178\" data-end=\"496\"\u003eLooking for \u003cstrong data-start=\"190\" data-end=\"224\"\u003eDometic 8500-III furnace parts\u003c\/strong\u003e or \u003cstrong data-start=\"228\" data-end=\"276\"\u003eAtwood 8500-III RV furnace replacement parts\u003c\/strong\u003e? You’ve found the right place. This page is dedicated to parts for \u003cstrong data-start=\"344\" data-end=\"398\"\u003eDometic (formerly Atwood) 8500-III Series furnaces\u003c\/strong\u003e—a widely used \u003cstrong data-start=\"413\" data-end=\"441\"\u003educted RV heating system\u003c\/strong\u003e known for strong performance and dependable operation.\u003c\/p\u003e\n\u003cp data-start=\"498\" data-end=\"697\"\u003eThe \u003cstrong data-start=\"502\" data-end=\"521\"\u003e8500-III series\u003c\/strong\u003e represents an updated generation of the 8500 platform, featuring improved components, better ignition reliability, and consistent airflow for efficient heating across your RV.\u003c\/p\u003e\n\u003chr data-start=\"1305\" data-end=\"1308\"\u003e\n\u003ch2 data-section-id=\"1ogfwiy\" data-start=\"1310\" data-end=\"1354\"\u003eFind the Right 8500-III Replacement Parts\u003c\/h2\u003e\n\u003cp data-start=\"1356\" data-end=\"1445\"\u003eThis category includes the most commonly replaced parts for 8500-III furnaces, including:\u003c\/p\u003e\n\u003cul data-start=\"1447\" data-end=\"1630\"\u003e\n\u003cli data-section-id=\"r74u6u\" data-start=\"1447\" data-end=\"1480\"\u003eBlower motors \u0026amp; blower wheels\u003c\/li\u003e\n\u003cli data-section-id=\"1kdnk9o\" data-start=\"1481\" data-end=\"1518\"\u003eControl boards \u0026amp; ignition modules\u003c\/li\u003e\n\u003cli data-section-id=\"t5upms\" data-start=\"1519\" data-end=\"1553\"\u003eGas valves \u0026amp; burner assemblies\u003c\/li\u003e\n\u003cli data-section-id=\"12y99m4\" data-start=\"1554\" data-end=\"1588\"\u003eSail switches \u0026amp; limit switches\u003c\/li\u003e\n\u003cli data-section-id=\"el3g6s\" data-start=\"1589\" data-end=\"1630\"\u003eCombustion chambers \u0026amp; heat exchangers\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"1632\" data-end=\"1688\"\u003eThese parts help fix common RV furnace problems such as:\u003c\/p\u003e\n\u003cul data-start=\"1689\" data-end=\"1803\"\u003e\n\u003cli data-section-id=\"v80mg8\" data-start=\"1689\" data-end=\"1713\"\u003eFurnace not igniting\u003c\/li\u003e\n\u003cli data-section-id=\"mcjs4d\" data-start=\"1714\" data-end=\"1744\"\u003eRV furnace not blowing air\u003c\/li\u003e\n\u003cli data-section-id=\"160asvw\" data-start=\"1745\" data-end=\"1772\"\u003eNo heat or weak airflow\u003c\/li\u003e\n\u003cli data-section-id=\"igxf3k\" data-start=\"1773\" data-end=\"1803\"\u003eFurnace cycling on and off\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1805\" data-end=\"1808\"\u003e\n\u003ch2 data-section-id=\"1wh2x4q\" data-start=\"1810\" data-end=\"1835\"\u003eImportant Fitment Note\u003c\/h2\u003e\n\u003cp data-start=\"1837\" data-end=\"2026\"\u003e8500-III furnaces may vary by \u003cstrong data-start=\"1867\" data-end=\"1899\"\u003eBTU rating and configuration\u003c\/strong\u003e, and some parts differ from earlier 8500-I and 8500-II models. Always confirm your exact model number to ensure compatibility.\u003c\/p\u003e","products":[{"product_id":"dometic-atwood-direct-spark-ignition-dsi-control-circuit-board-31501","title":"Dometic \/ Atwood Direct Spark Ignition (DSI) Control Circuit Board - 31501 (Superseded #38676)","description":"\u003cp data-start=\"150\" data-end=\"497\"\u003eRestore reliable furnace ignition and fan operation with this Dometic Ignition Control Circuit Board, engineered for use in Atwood and Hydro Flame RV furnaces equipped with Direct Spark Ignition (DSI). This 12-volt control board manages spark ignition and furnace blower sequencing, helping ensure safe startups and consistent heating performance.\u003c\/p\u003e\n\u003cp data-start=\"499\" data-end=\"683\"\u003eThis replacement board includes integrated fan control and an on-board relay for proper ignition timing and blower operation. Two mounting spacers are included for secure installation.\u003c\/p\u003e\n\u003cp data-start=\"499\" data-end=\"683\"\u003eThis part replaces #38676.\u003c\/p\u003e\n\u003ch2 data-start=\"685\" data-end=\"697\"\u003eImportant:\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli data-start=\"700\" data-end=\"727\"\u003eExcludes 2-stage furnaces\u003c\/li\u003e\n\u003cli data-start=\"730\" data-end=\"750\"\u003eExcludes AC models\u003c\/li\u003e\n\u003cli data-start=\"753\" data-end=\"830\"\u003eDoes NOT include Green Pin Adapter Part #35325 (order separately if required)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-start=\"832\" data-end=\"845\"\u003eKey Features:\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli data-start=\"849\" data-end=\"885\"\u003e12-Volt DSI ignition control board\u003c\/li\u003e\n\u003cli data-start=\"888\" data-end=\"945\"\u003eDesigned for single-stage Atwood \/ Hydro Flame furnaces\u003c\/li\u003e\n\u003cli data-start=\"948\" data-end=\"972\"\u003eIntegrated fan control\u003c\/li\u003e\n\u003cli data-start=\"975\" data-end=\"1024\"\u003eOn-board relay for ignition and blower sequence\u003c\/li\u003e\n\u003cli data-start=\"1027\" data-end=\"1058\"\u003eIncludes two mounting spacers\u003c\/li\u003e\n\u003cli data-start=\"1061\" data-end=\"1091\"\u003eDirect OEM-style replacement\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-start=\"1093\" data-end=\"1136\"\u003eCommon Symptoms of a Failing Control Board:\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli data-start=\"1140\" data-end=\"1176\"\u003eFurnace clicks but does not ignite\u003c\/li\u003e\n\u003cli data-start=\"1179\" data-end=\"1219\"\u003eBlower runs continuously without flame\u003c\/li\u003e\n\u003cli data-start=\"1222\" data-end=\"1264\"\u003eFurnace locks out after ignition attempt\u003c\/li\u003e\n\u003cli data-start=\"1267\" data-end=\"1292\"\u003eIntermittent or no heat\u003c\/li\u003e\n\u003cli data-start=\"1295\" data-end=\"1324\"\u003eNo response from thermostat\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"1326\" data-end=\"1433\"\u003eReplacing a failed ignition board is one of the most common fixes for Atwood DSI furnace ignition problems.\u003c\/p\u003e\n\u003ch2 data-start=\"1435\" data-end=\"1454\"\u003eCompatible Furnaces\u003c\/h2\u003e\n\u003cp data-start=\"1456\" data-end=\"1565\"\u003eCompatible with the following Atwood \/ Hydro Flame \/ Dometic single-stage Direct Spark Ignition (DSI) models:\u003c\/p\u003e\n\u003cp data-start=\"1567\" data-end=\"1673\"\u003e\u003cspan style=\"text-decoration: underline;\"\u003eAtwood Hydro Flame Series:\u003c\/span\u003e\u003cbr\u003e7912-II\u003cbr data-start=\"1601\" data-end=\"1604\"\u003e7916-II\u003cbr data-start=\"1611\" data-end=\"1614\"\u003e7920-II\u003cbr data-start=\"1621\" data-end=\"1624\"\u003e8012-II\u003cbr data-start=\"1631\" data-end=\"1634\"\u003eFA7912D\u003cbr data-start=\"1641\" data-end=\"1644\"\u003eFA7916D\u003cbr data-start=\"1651\" data-end=\"1654\"\u003eFA7920D\u003cbr data-start=\"1661\" data-end=\"1664\"\u003eHF8012D\u003c\/p\u003e\n\u003cp data-start=\"1675\" data-end=\"1786\"\u003e\u003cspan style=\"text-decoration: underline;\"\u003eDometic \/ Atwood DC \u0026amp; FA Series:\u003c\/span\u003e\u003cbr\u003eDC8225\u003cbr data-start=\"1714\" data-end=\"1717\"\u003eDC8232\u003cbr data-start=\"1723\" data-end=\"1726\"\u003eDC8235\u003cbr data-start=\"1732\" data-end=\"1735\"\u003eDC8241\u003cbr data-start=\"1741\" data-end=\"1744\"\u003eFA76D\u003cbr data-start=\"1749\" data-end=\"1752\"\u003eFA7615D\u003cbr data-start=\"1759\" data-end=\"1762\"\u003eFA7825\u003cbr data-start=\"1768\" data-end=\"1771\"\u003eFA7832\u003cbr data-start=\"1777\" data-end=\"1780\"\u003eFA72\u003c\/p\u003e\n\u003cp data-start=\"1788\" data-end=\"1880\"\u003e\u003cspan style=\"text-decoration: underline;\"\u003eHydro Flame 8500 Series:\u003c\/span\u003e\u003cbr\u003e8500-IV Series\u003cbr data-start=\"1827\" data-end=\"1830\"\u003e8500-III Series\u003cbr data-start=\"1845\" data-end=\"1848\"\u003e8500-II Series\u003cbr data-start=\"1862\" data-end=\"1865\"\u003e8500-I Series\u003c\/p\u003e\n\u003cp data-start=\"1882\" data-end=\"1967\"\u003e\u003cspan style=\"text-decoration: underline;\"\u003eHydro Flame 8900 IDC Series:\u003c\/span\u003e\u003cbr\u003e8900-IDC Series\u003cbr data-start=\"1926\" data-end=\"1929\"\u003e8900-IIDC Series\u003cbr data-start=\"1945\" data-end=\"1948\"\u003e8900-IIIDC Series\u003c\/p\u003e\n\u003cp data-start=\"1969\" data-end=\"2117\"\u003e\u003cspan style=\"text-decoration: underline;\"\u003eAtwood \/ Dometic AFSD \u0026amp; AFMD Series:\u003c\/span\u003e\u003cbr\u003eAFSD12 Series\u003cbr data-start=\"2019\" data-end=\"2022\"\u003eAFSD16 Series\u003cbr data-start=\"2035\" data-end=\"2038\"\u003eAFSD20 Series\u003cbr data-start=\"2051\" data-end=\"2054\"\u003eAFMD20 Series\u003cbr data-start=\"2067\" data-end=\"2070\"\u003eAFMD25 Series\u003cbr data-start=\"2083\" data-end=\"2086\"\u003eAFMD30 Series\u003cbr data-start=\"2099\" data-end=\"2102\"\u003eAFMD35 Series\u003c\/p\u003e\n\u003cp data-start=\"2119\" data-end=\"2230\"\u003e\u003cspan style=\"text-decoration: underline;\"\u003eDometic DFMD \u0026amp; DFSD Models:\u003c\/span\u003e\u003cbr\u003eDFMD20111\u003cbr data-start=\"2156\" data-end=\"2159\"\u003eDFMD25111\u003cbr data-start=\"2168\" data-end=\"2171\"\u003eDFMD30111\u003cbr data-start=\"2180\" data-end=\"2183\"\u003eDFMD35111\u003cbr data-start=\"2192\" data-end=\"2195\"\u003eDFSD12111\u003cbr data-start=\"2204\" data-end=\"2207\"\u003eDFSD16111\u003cbr data-start=\"2216\" data-end=\"2219\"\u003eDFSD20111\u003c\/p\u003e\n\u003cp data-start=\"2232\" data-end=\"2332\"\u003eAlways verify your furnace model number and confirm it is a single-stage DSI system before ordering.\u003c\/p\u003e\n\u003ch2 data-start=\"2334\" data-end=\"2350\"\u003eWhat’s Included:\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli data-start=\"2354\" data-end=\"2394\"\u003e(1) 12V Ignition Control Circuit Board\u003c\/li\u003e\n\u003cli data-start=\"2397\" data-end=\"2419\"\u003e(2) Mounting Spacers\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"2421\" data-end=\"2498\"\u003eGreen Pin Adapter #35325 sold separately if required for your wiring harness.\u003c\/p\u003e","brand":"RV Furnace Guys","offers":[{"title":"Default Title","offer_id":47821938360561,"sku":null,"price":223.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0784\/4941\/0289\/files\/315011.png?v=1771805322"},{"product_id":"dometic-atwood-rv-furnace-igniter-electrode-part-35100","title":"Dometic \/ Atwood RV Furnace Igniter Electrode – Part #35100","description":"\u003cp data-start=\"63\" data-end=\"390\"\u003eRestore strong, reliable ignition with the Dometic \/ Atwood Igniter Electrode, Part #35100. This OEM-style replacement electrode generates the spark that ignites propane inside your RV furnace burner assembly. If your furnace clicks repeatedly but fails to light, replacing a worn or cracked igniter electrode is often the fix.\u003c\/p\u003e\n\u003cp data-start=\"392\" data-end=\"548\"\u003eBuilt to meet original equipment specifications, Part #35100 ensures proper spark positioning, consistent ignition, and dependable cold-weather performance.\u003c\/p\u003e\n\u003chr data-start=\"550\" data-end=\"553\"\u003e\n\u003ch2 data-start=\"555\" data-end=\"568\"\u003eKey Features:\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli data-start=\"572\" data-end=\"621\"\u003eOEM Replacement Igniter Electrode – Part #35100\u003c\/li\u003e\n\u003cli data-start=\"624\" data-end=\"692\"\u003eDesigned for Atwood \/ Dometic Direct Spark Ignition (DSI) furnaces\u003c\/li\u003e\n\u003cli data-start=\"695\" data-end=\"751\"\u003eProduces consistent spark for reliable burner ignition\u003c\/li\u003e\n\u003cli data-start=\"754\" data-end=\"800\"\u003eHigh-temperature resistant ceramic insulator\u003c\/li\u003e\n\u003cli data-start=\"803\" data-end=\"859\"\u003eFactory-style mounting for correct spark gap alignment\u003c\/li\u003e\n\u003cli data-start=\"862\" data-end=\"908\"\u003eDirect-fit replacement for compatible models\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"910\" data-end=\"913\"\u003e\n\u003ch2 data-start=\"915\" data-end=\"962\"\u003eCommon Symptoms of a Failing Igniter Electrode:\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli data-start=\"966\" data-end=\"1013\"\u003eFurnace clicks repeatedly but does not ignite\u003c\/li\u003e\n\u003cli data-start=\"1016\" data-end=\"1056\"\u003eIntermittent ignition or delayed flame\u003c\/li\u003e\n\u003cli data-start=\"1059\" data-end=\"1089\"\u003eBurner lights inconsistently\u003c\/li\u003e\n\u003cli data-start=\"1092\" data-end=\"1129\"\u003eVisible crack in ceramic insulation\u003c\/li\u003e\n\u003cli data-start=\"1132\" data-end=\"1158\"\u003eWeak or misaligned spark\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"1160\" data-end=\"1285\"\u003eOver time, heat cycling and vibration can cause the electrode to crack or shift out of alignment, preventing proper ignition.\u003c\/p\u003e\n\u003chr data-start=\"1287\" data-end=\"1290\"\u003e\n\u003ch2 data-start=\"1292\" data-end=\"1348\"\u003eCompatible With the Following Dometic \/ Atwood Furnaces:\u003c\/h2\u003e\n\u003ch3 data-start=\"1530\" data-end=\"1547\"\u003eAFLA Series\u003c\/h3\u003e\n\u003cp data-start=\"1548\" data-end=\"1619\"\u003eAFLA35211\u003cbr data-start=\"1557\" data-end=\"1560\"\u003eAFLA35221\u003cbr data-start=\"1569\" data-end=\"1572\"\u003eAFLA35231\u003cbr data-start=\"1581\" data-end=\"1584\"\u003eAFLA40211\u003cbr data-start=\"1593\" data-end=\"1596\"\u003eAFLA40221\u003cbr data-start=\"1605\" data-end=\"1608\"\u003eAFLA40231\u003c\/p\u003e\n\u003ch3 data-start=\"1621\" data-end=\"1638\"\u003eAFLD Series\u003c\/h3\u003e\n\u003cp data-start=\"1639\" data-end=\"1710\"\u003eAFLD35111\u003cbr data-start=\"1648\" data-end=\"1651\"\u003eAFLD35121\u003cbr data-start=\"1660\" data-end=\"1663\"\u003eAFLD35131\u003cbr data-start=\"1672\" data-end=\"1675\"\u003eAFLD40111\u003cbr data-start=\"1684\" data-end=\"1687\"\u003eAFLD40121\u003cbr data-start=\"1696\" data-end=\"1699\"\u003eAFLD40131\u003c\/p\u003e\n\u003chr data-start=\"1712\" data-end=\"1715\"\u003e\n\u003ch3 data-start=\"1717\" data-end=\"1734\"\u003eAFMD Series\u003c\/h3\u003e\n\u003cp data-start=\"1735\" data-end=\"2034\"\u003eAFMD16111\u003cbr data-start=\"1744\" data-end=\"1747\"\u003eAFMD16121\u003cbr data-start=\"1756\" data-end=\"1759\"\u003eAFMD16131\u003cbr data-start=\"1768\" data-end=\"1771\"\u003eAFMD16141\u003cbr data-start=\"1780\" data-end=\"1783\"\u003eAFMD16151\u003cbr data-start=\"1792\" data-end=\"1795\"\u003eAFMD20111\u003cbr data-start=\"1804\" data-end=\"1807\"\u003eAFMD20121\u003cbr data-start=\"1816\" data-end=\"1819\"\u003eAFMD20131\u003cbr data-start=\"1828\" data-end=\"1831\"\u003eAFMD20141\u003cbr data-start=\"1840\" data-end=\"1843\"\u003eAFMD20151\u003cbr data-start=\"1852\" data-end=\"1855\"\u003eAFMD25111\u003cbr data-start=\"1864\" data-end=\"1867\"\u003eAFMD25121\u003cbr data-start=\"1876\" data-end=\"1879\"\u003eAFMD25131\u003cbr data-start=\"1888\" data-end=\"1891\"\u003eAFMD25141\u003cbr data-start=\"1900\" data-end=\"1903\"\u003eAFMD25151\u003cbr data-start=\"1912\" data-end=\"1915\"\u003eAFMD30111\u003cbr data-start=\"1924\" data-end=\"1927\"\u003eAFMD30121\u003cbr data-start=\"1936\" data-end=\"1939\"\u003eAFMD30131\u003cbr data-start=\"1948\" data-end=\"1951\"\u003eAFMD30141\u003cbr data-start=\"1960\" data-end=\"1963\"\u003eAFMD30151\u003cbr data-start=\"1972\" data-end=\"1975\"\u003eAFMD35111\u003cbr data-start=\"1984\" data-end=\"1987\"\u003eAFMD35121\u003cbr data-start=\"1996\" data-end=\"1999\"\u003eAFMD35131\u003cbr data-start=\"2008\" data-end=\"2011\"\u003eAFMD35141\u003cbr data-start=\"2020\" data-end=\"2023\"\u003eAFMD35151\u003c\/p\u003e\n\u003chr data-start=\"2036\" data-end=\"2039\"\u003e\n\u003ch3 data-start=\"2041\" data-end=\"2059\"\u003eAFSAD Series\u003c\/h3\u003e\n\u003cp data-start=\"2060\" data-end=\"2111\"\u003eAFSAD12111\u003cbr data-start=\"2070\" data-end=\"2073\"\u003eAFSAD12121\u003cbr data-start=\"2083\" data-end=\"2086\"\u003eAFSAD12131\u003cbr data-start=\"2096\" data-end=\"2099\"\u003eAFSAD12141\u003c\/p\u003e\n\u003ch3 data-start=\"2113\" data-end=\"2130\"\u003eAFSD Series\u003c\/h3\u003e\n\u003cp data-start=\"2131\" data-end=\"2274\"\u003eAFSD12111\u003cbr data-start=\"2140\" data-end=\"2143\"\u003eAFSD12121\u003cbr data-start=\"2152\" data-end=\"2155\"\u003eAFSD12131\u003cbr data-start=\"2164\" data-end=\"2167\"\u003eAFSD12141\u003cbr data-start=\"2176\" data-end=\"2179\"\u003eAFSD16111\u003cbr data-start=\"2188\" data-end=\"2191\"\u003eAFSD16121\u003cbr data-start=\"2200\" data-end=\"2203\"\u003eAFSD16131\u003cbr data-start=\"2212\" data-end=\"2215\"\u003eAFSD16141\u003cbr data-start=\"2224\" data-end=\"2227\"\u003eAFSD20111\u003cbr data-start=\"2236\" data-end=\"2239\"\u003eAFSD20121\u003cbr data-start=\"2248\" data-end=\"2251\"\u003eAFSD20131\u003cbr data-start=\"2260\" data-end=\"2263\"\u003eAFSD20141\u003c\/p\u003e\n\u003chr data-start=\"2276\" data-end=\"2279\"\u003e\n\u003ch3 data-start=\"2281\" data-end=\"2298\"\u003eDFLA Series\u003c\/h3\u003e\n\u003cp data-start=\"2299\" data-end=\"2370\"\u003eDFLA35211\u003cbr data-start=\"2308\" data-end=\"2311\"\u003eDFLA35221\u003cbr data-start=\"2320\" data-end=\"2323\"\u003eDFLA35231\u003cbr data-start=\"2332\" data-end=\"2335\"\u003eDFLA40211\u003cbr data-start=\"2344\" data-end=\"2347\"\u003eDFLA40221\u003cbr data-start=\"2356\" data-end=\"2359\"\u003eDFLA40231\u003c\/p\u003e\n\u003ch3 data-start=\"2372\" data-end=\"2389\"\u003eDFLD Series\u003c\/h3\u003e\n\u003cp data-start=\"2390\" data-end=\"2461\"\u003eDFLD35111\u003cbr data-start=\"2399\" data-end=\"2402\"\u003eDFLD35121\u003cbr data-start=\"2411\" data-end=\"2414\"\u003eDFLD35131\u003cbr data-start=\"2423\" data-end=\"2426\"\u003eDFLD40111\u003cbr data-start=\"2435\" data-end=\"2438\"\u003eDFLD40121\u003cbr data-start=\"2447\" data-end=\"2450\"\u003eDFLD40131\u003c\/p\u003e\n\u003chr data-start=\"2463\" data-end=\"2466\"\u003e\n\u003ch3 data-start=\"2468\" data-end=\"2485\"\u003eDFMD Series\u003c\/h3\u003e\n\u003cp data-start=\"2486\" data-end=\"2798\"\u003eDFMD16111\u003cbr data-start=\"2495\" data-end=\"2498\"\u003eDFMD16121\u003cbr data-start=\"2507\" data-end=\"2510\"\u003eDFMD16131\u003cbr data-start=\"2519\" data-end=\"2522\"\u003eDFMD16141\u003cbr data-start=\"2531\" data-end=\"2534\"\u003eDFMD16151\u003cbr data-start=\"2543\" data-end=\"2546\"\u003eDFMD20111\u003cbr data-start=\"2555\" data-end=\"2558\"\u003eDFMD20121\u003cbr data-start=\"2567\" data-end=\"2570\"\u003eDFMD20131\u003cbr data-start=\"2579\" data-end=\"2582\"\u003eDFMD20141\u003cbr data-start=\"2591\" data-end=\"2594\"\u003eDFMD20151\u003cbr data-start=\"2603\" data-end=\"2606\"\u003eDFMD25111\u003cbr data-start=\"2615\" data-end=\"2618\"\u003eDFMD25121\u003cbr data-start=\"2627\" data-end=\"2630\"\u003eDFMD25131\u003cbr data-start=\"2639\" data-end=\"2642\"\u003eDFMD25141\u003cbr data-start=\"2651\" data-end=\"2654\"\u003eDFMD25151\u003cbr data-start=\"2663\" data-end=\"2666\"\u003eDFMD30111\u003cbr data-start=\"2675\" data-end=\"2678\"\u003eDFMD30121\u003cbr data-start=\"2687\" data-end=\"2690\"\u003eDFMD30131\u003cbr data-start=\"2699\" data-end=\"2702\"\u003eDFMD30141\u003cbr data-start=\"2711\" data-end=\"2714\"\u003eDFMD30151\u003cbr data-start=\"2723\" data-end=\"2726\"\u003eDFMD35111\u003cbr data-start=\"2735\" data-end=\"2738\"\u003eDFMD35121\u003cbr data-start=\"2747\" data-end=\"2750\"\u003eDFMD35131\u003cbr data-start=\"2759\" data-end=\"2762\"\u003eDFMD35141\u003cbr data-start=\"2771\" data-end=\"2774\"\u003eDFMD35151\u003cbr data-start=\"2783\" data-end=\"2786\"\u003eDFMD35121W\u003c\/p\u003e\n\u003chr data-start=\"2800\" data-end=\"2803\"\u003e\n\u003ch3 data-start=\"2805\" data-end=\"2823\"\u003eDFSAD Series\u003c\/h3\u003e\n\u003cp data-start=\"2824\" data-end=\"2875\"\u003eDFSAD12111\u003cbr data-start=\"2834\" data-end=\"2837\"\u003eDFSAD12121\u003cbr data-start=\"2847\" data-end=\"2850\"\u003eDFSAD12131\u003cbr data-start=\"2860\" data-end=\"2863\"\u003eDFSAD12141\u003c\/p\u003e\n\u003ch3 data-start=\"2877\" data-end=\"2894\"\u003eDFSD Series\u003c\/h3\u003e\n\u003cp data-start=\"2895\" data-end=\"3038\"\u003eDFSD12111\u003cbr data-start=\"2904\" data-end=\"2907\"\u003eDFSD12121\u003cbr data-start=\"2916\" data-end=\"2919\"\u003eDFSD12131\u003cbr data-start=\"2928\" data-end=\"2931\"\u003eDFSD12141\u003cbr data-start=\"2940\" data-end=\"2943\"\u003eDFSD16111\u003cbr data-start=\"2952\" data-end=\"2955\"\u003eDFSD16121\u003cbr data-start=\"2964\" data-end=\"2967\"\u003eDFSD16131\u003cbr data-start=\"2976\" data-end=\"2979\"\u003eDFSD16141\u003cbr data-start=\"2988\" data-end=\"2991\"\u003eDFSD20111\u003cbr data-start=\"3000\" data-end=\"3003\"\u003eDFSD20121\u003cbr data-start=\"3012\" data-end=\"3015\"\u003eDFSD20131\u003cbr data-start=\"3024\" data-end=\"3027\"\u003eDFSD20141\u003c\/p\u003e\n\u003cp data-start=\"1758\" data-end=\"1855\"\u003eAlways verify your furnace model and confirm it uses Direct Spark Ignition (DSI) before ordering.\u003c\/p\u003e\n\u003chr data-start=\"1857\" data-end=\"1860\"\u003e\n\u003ch2 data-start=\"1862\" data-end=\"1878\"\u003eWhat’s Included:\u003c\/h2\u003e\n\u003cul data-start=\"1880\" data-end=\"1919\"\u003e\n\u003cli data-start=\"1880\" data-end=\"1919\"\u003e\n\u003cp data-start=\"1882\" data-end=\"1919\"\u003e(1) Igniter Electrode – Part #35100\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"1921\" data-end=\"2012\"\u003eMounting hardware may vary by furnace model. Inspect existing hardware during installation.\u003c\/p\u003e\n\u003chr data-start=\"2014\" data-end=\"2017\"\u003e\n\u003ch2 data-start=\"2019\" data-end=\"2038\"\u003eInstallation Notes:\u003c\/h2\u003e\n\u003cp data-start=\"2040\" data-end=\"2221\"\u003eDisconnect 12V power and shut off propane before servicing your furnace. Proper spark gap alignment is critical — refer to your furnace service manual for adjustment specifications.\u003c\/p\u003e\n\u003chr data-start=\"2223\" data-end=\"2226\"\u003e\n\u003ch2 data-start=\"2228\" data-end=\"2254\"\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003cp data-start=\"2256\" data-end=\"2392\"\u003eWhat does the igniter electrode do?\u003cbr data-start=\"2291\" data-end=\"2294\"\u003eIt creates the spark that ignites propane in the burner chamber during the furnace start sequence.\u003c\/p\u003e\n\u003cp data-start=\"2394\" data-end=\"2532\"\u003eIs this the same as the flame sensor?\u003cbr data-start=\"2431\" data-end=\"2434\"\u003eIn many Atwood\/Dometic furnaces, the igniter electrode also serves as the flame sensing electrode.\u003c\/p\u003e\n\u003cp data-start=\"2534\" data-end=\"2742\"\u003eWill this fix a furnace that clicks but won’t light?\u003cbr data-start=\"2586\" data-end=\"2589\"\u003eIf gas flow is present and the control board is functioning, a worn or cracked igniter electrode is a common cause of repeated clicking without ignition.\u003c\/p\u003e\n\u003cp data-start=\"2744\" data-end=\"2868\"\u003eHow do I know if mine is bad?\u003cbr data-start=\"2773\" data-end=\"2776\"\u003eLook for cracks in the ceramic, weak spark, improper gap, or corrosion on the electrode tip.\u003c\/p\u003e","brand":"RV Furnace Guys","offers":[{"title":"Default Title","offer_id":47828907360497,"sku":null,"price":49.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0784\/4941\/0289\/files\/35100IgniterElectrode.png?v=1772064866"},{"product_id":"dometic-atwood-33755-rv-furnace-exterior-access-door-for-8500-8900-xt-black","title":"Dometic \/ Atwood 33755 RV Furnace Exterior Access Door for 8500, 8900, XT – Black - SPECIAL ORDER","description":"\u003ch2 data-end=\"259\" data-start=\"192\"\u003eDometic \/ Atwood 33755 RV Furnace Exterior Access Door – Black\u003c\/h2\u003e\n\u003cp data-end=\"316\" data-start=\"260\"\u003e\u003cstrong data-end=\"316\" data-start=\"260\"\u003eSpecial Order Item (5–15 Business Days for Delivery)\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-end=\"413\" data-start=\"318\"\u003e\u003cstrong data-end=\"334\" data-start=\"318\"\u003ePart Number:\u003c\/strong\u003e 33755\u003cbr data-end=\"343\" data-start=\"340\"\u003e\u003cstrong data-end=\"370\" data-start=\"343\"\u003eGenuine OEM Replacement\u003c\/strong\u003e\u003cbr data-end=\"373\" data-start=\"370\"\u003e\u003cstrong data-end=\"413\" data-start=\"373\"\u003eLimited 2-Year Manufacturer Warranty\u003c\/strong\u003e\u003c\/p\u003e\n\u003chr data-end=\"418\" data-start=\"415\"\u003e\n\u003ch3 data-end=\"440\" data-start=\"420\"\u003eProduct Overview\u003c\/h3\u003e\n\u003cp data-end=\"603\" data-start=\"442\"\u003eThe Dometic\/Atwood 33755 Furnace Exterior Access Door is a genuine OEM replacement panel designed for select legacy Atwood 8500, 8900, and XT series RV furnaces.\u003c\/p\u003e\n\u003cp data-end=\"872\" data-start=\"605\"\u003eEngineered to factory specifications, this exterior door provides secure access to the furnace compartment while maintaining proper airflow and ventilation. It restores your RV’s clean exterior appearance and ensures safe, accessible servicing of your heating system.\u003c\/p\u003e\n\u003cp data-end=\"1008\" data-start=\"874\"\u003eThis door assembly is built for durability in outdoor RV environments and withstands vibration, road exposure, and weather conditions.\u003c\/p\u003e\n\u003cp data-end=\"1113\" data-start=\"1010\"\u003e\u003cstrong data-end=\"1026\" data-start=\"1010\"\u003ePlease Note:\u003c\/strong\u003e This item is a \u003cem data-end=\"1057\" data-start=\"1042\"\u003eSpecial Order\u003c\/em\u003e part and typically ships within \u003cstrong data-end=\"1112\" data-start=\"1090\"\u003e7–14 business days\u003c\/strong\u003e.\u003c\/p\u003e\n\u003chr data-end=\"1118\" data-start=\"1115\"\u003e\n\u003ch3 data-end=\"1136\" data-start=\"1120\"\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli data-end=\"1187\" data-start=\"1140\"\u003eGenuine OEM Dometic \/ Atwood replacement part\u003c\/li\u003e\n\u003cli data-end=\"1245\" data-start=\"1190\"\u003eDesigned for legacy 8500, 8900, and XT furnace series\u003c\/li\u003e\n\u003cli data-end=\"1279\" data-start=\"1248\"\u003eDurable black exterior finish\u003c\/li\u003e\n\u003cli data-end=\"1314\" data-start=\"1282\"\u003eWeather-resistant construction\u003c\/li\u003e\n\u003cli data-end=\"1371\" data-start=\"1317\"\u003eMaintains correct furnace airflow and service access\u003c\/li\u003e\n\u003cli data-end=\"1425\" data-start=\"1374\"\u003eManufactured to original equipment specifications\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1521\" data-start=\"1469\"\u003eSpecial Order item (7–14 business days for delivery)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-end=\"1526\" data-start=\"1523\"\u003e\n\u003ch3 data-end=\"1557\" data-start=\"1528\"\u003eCompatible Furnace Models\u003c\/h3\u003e\n\u003cp data-end=\"1618\" data-start=\"1559\"\u003ePart 33755 is compatible with the following furnace series:\u003c\/p\u003e\n\u003cp data-end=\"1635\" data-start=\"1620\"\u003e\u003cstrong data-end=\"1635\" data-start=\"1620\"\u003e8500 Series\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli data-end=\"1647\" data-start=\"1638\"\u003e8500 II\u003c\/li\u003e\n\u003cli data-end=\"1660\" data-start=\"1650\"\u003e8500 III\u003c\/li\u003e\n\u003cli data-end=\"1672\" data-start=\"1663\"\u003e8500 IV\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-end=\"1689\" data-start=\"1674\"\u003e\u003cstrong data-end=\"1689\" data-start=\"1674\"\u003e8900 Series\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli data-end=\"1700\" data-start=\"1692\"\u003e8900 I\u003c\/li\u003e\n\u003cli data-end=\"1712\" data-start=\"1703\"\u003e8900 II\u003c\/li\u003e\n\u003cli data-end=\"1725\" data-start=\"1715\"\u003e8900 III\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-end=\"1740\" data-start=\"1727\"\u003e\u003cstrong data-end=\"1740\" data-start=\"1727\"\u003eXT Series\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-end=\"1766\" data-start=\"1741\"\u003e\n\u003cli data-end=\"1766\" data-start=\"1741\"\u003e\n\u003cp data-end=\"1766\" data-start=\"1743\"\u003eHydro Flame XT models\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-end=\"1935\" data-start=\"1768\"\u003eImportant: Always verify the furnace model number on your unit’s data plate before ordering, as some configurations and suffix variations may require a different door.\u003c\/p\u003e\n\u003chr data-end=\"1940\" data-start=\"1937\"\u003e\n\u003ch3 data-end=\"1968\" data-start=\"1942\"\u003eProduct Specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli data-end=\"2004\" data-start=\"1972\"\u003eManufacturer: Dometic \/ Atwood\u003c\/li\u003e\n\u003cli data-end=\"2027\" data-start=\"2007\"\u003ePart Number: 33755\u003c\/li\u003e\n\u003cli data-end=\"2044\" data-start=\"2030\"\u003eColor: Black\u003c\/li\u003e\n\u003cli data-end=\"2090\" data-start=\"2047\"\u003eApplication: Exterior furnace access door\u003c\/li\u003e\n\u003cli data-end=\"2128\" data-start=\"2093\"\u003eCompatible Series: 8500, 8900, XT\u003c\/li\u003e\n\u003cli data-end=\"2194\" data-start=\"2131\"\u003eIncludes: Door assembly only (mounting hardware not included)\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"2298\" data-start=\"2248\"\u003eAvailability: \u003cem data-end=\"2298\" data-start=\"2262\"\u003eSpecial Order – 7–14 Business Days\u003c\/em\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-end=\"2303\" data-start=\"2300\"\u003e\n\u003ch2 data-end=\"2340\" data-start=\"2305\"\u003eFrequently Asked Questions (FAQ)\u003c\/h2\u003e\n\u003ch3 data-end=\"2393\" data-start=\"2342\"\u003eQ: What furnace series does the 33755 door fit?\u003c\/h3\u003e\n\u003cp data-end=\"2483\" data-start=\"2394\"\u003eA: It fits select legacy Atwood 8500 II, III, IV; 8900 I, II, III; and XT furnace models.\u003c\/p\u003e\n\u003chr data-end=\"2488\" data-start=\"2485\"\u003e\n\u003ch3 data-end=\"2540\" data-start=\"2490\"\u003eQ: Does this fit DFMD or DFSD series furnaces?\u003c\/h3\u003e\n\u003cp data-end=\"2678\" data-start=\"2541\"\u003eA: No. The 33755 door is designed for older 8500, 8900, and XT series furnaces. Newer DF-series furnaces use different door part numbers.\u003c\/p\u003e\n\u003chr data-end=\"2683\" data-start=\"2680\"\u003e\n\u003ch3 data-end=\"2760\" data-start=\"2685\"\u003eQ: Is this compatible with both single-stage and XT two-stage furnaces?\u003c\/h3\u003e\n\u003cp data-end=\"2873\" data-start=\"2761\"\u003eA: Yes, this door fits compatible XT-series two-stage furnaces as well as the listed 8500 and 8900 series units.\u003c\/p\u003e\n\u003chr data-end=\"2878\" data-start=\"2875\"\u003e\n\u003ch3 data-end=\"2922\" data-start=\"2880\"\u003eQ: Is this an OEM Dometic\/Atwood part?\u003c\/h3\u003e\n\u003cp data-end=\"2987\" data-start=\"2923\"\u003eA: Yes. 33755 is a genuine OEM replacement exterior access door.\u003c\/p\u003e\n\u003chr data-end=\"2992\" data-start=\"2989\"\u003e\n\u003ch3 data-end=\"3039\" data-start=\"2994\"\u003eQ: Why is this item marked Special Order?\u003c\/h3\u003e\n\u003cp data-end=\"3173\" data-start=\"3040\"\u003eA: This is a legacy furnace part that is not typically stocked for immediate shipment. Estimated delivery time is 7–14 business days.\u003c\/p\u003e\n\u003chr data-end=\"3178\" data-start=\"3175\"\u003e\n\u003ch3 data-end=\"3225\" data-start=\"3180\"\u003eQ: Does the door include mounting screws?\u003c\/h3\u003e\n\u003cp data-end=\"3267\" data-start=\"3226\"\u003eA: No. Mounting hardware is not included.\u003c\/p\u003e\n\u003chr data-end=\"3272\" data-start=\"3269\"\u003e\n\u003ch3 data-end=\"3301\" data-start=\"3274\"\u003eQ: Is there a warranty?\u003c\/h3\u003e\n\u003cp data-end=\"3417\" data-start=\"3302\"\u003eA: Yes. This product includes a Limited 2-Year Manufacturer Warranty covering defects in materials and workmanship.\u003c\/p\u003e\n\u003chr data-end=\"3422\" data-start=\"3419\"\u003e\n\u003cp data-end=\"3666\" data-start=\"3449\"\u003e \u003c\/p\u003e","brand":"RV Furnace Guys","offers":[{"title":"Default Title","offer_id":47850063659249,"sku":null,"price":105.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0784\/4941\/0289\/files\/33755.jpg?v=1772237665"},{"product_id":"dometic-atwood-33126-furnace-blower-wheel-replaces-37764-with-clamp-for-8500-series","title":"Dometic \/ Atwood 33126 Furnace Blower Wheel – 8500 Series \u0026 AF \/ DF Models","description":"\u003ch2 data-start=\"136\" data-end=\"214\"\u003eDometic \/ Atwood 33126 Furnace Blower Wheel – Replaces 37764 (With Clamp)\u003c\/h2\u003e\n\u003cp data-start=\"215\" data-end=\"253\"\u003e\u003cstrong data-start=\"215\" data-end=\"253\"\u003eIn Stock – Genuine OEM Replacement\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"255\" data-end=\"342\"\u003e\u003cstrong data-start=\"255\" data-end=\"271\"\u003ePart Number:\u003c\/strong\u003e 33126\u003cbr data-start=\"277\" data-end=\"280\"\u003e\u003cstrong data-start=\"280\" data-end=\"293\"\u003eReplaces:\u003c\/strong\u003e 37764\u003cbr data-start=\"299\" data-end=\"302\"\u003e\u003cstrong data-start=\"302\" data-end=\"319\"\u003eProduct Type:\u003c\/strong\u003e Furnace Blower Wheel\u003c\/p\u003e\n\u003chr data-start=\"344\" data-end=\"347\"\u003e\n\u003ch3 data-start=\"349\" data-end=\"369\"\u003eProduct Overview\u003c\/h3\u003e\n\u003cp data-start=\"371\" data-end=\"537\"\u003eThe \u003cstrong data-start=\"375\" data-end=\"422\"\u003eDometic \/ Atwood 33126 Furnace Blower Wheel\u003c\/strong\u003e is a genuine OEM replacement designed to restore proper airflow and heating performance in select Atwood furnaces.\u003c\/p\u003e\n\u003cp data-start=\"539\" data-end=\"825\"\u003eThis precision-balanced blower wheel ensures efficient air movement through the combustion chamber and heat exchanger, helping maintain safe furnace operation. Part 33126 \u003cstrong data-start=\"710\" data-end=\"749\"\u003ereplaces obsolete part number 37764\u003c\/strong\u003e and includes the required clamp for secure installation on the motor shaft.\u003c\/p\u003e\n\u003cp data-start=\"827\" data-end=\"968\"\u003eManufactured to original equipment standards, this component is built for durability and dependable performance in demanding RV environments.\u003c\/p\u003e\n\u003chr data-start=\"970\" data-end=\"973\"\u003e\n\u003ch3 data-start=\"975\" data-end=\"991\"\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli data-start=\"995\" data-end=\"1042\"\u003eGenuine OEM Dometic \/ Atwood replacement part\u003c\/li\u003e\n\u003cli data-start=\"1045\" data-end=\"1084\"\u003eDirect replacement for part \u003cstrong data-start=\"1073\" data-end=\"1082\"\u003e37764\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1087\" data-end=\"1139\"\u003eIncludes clamp for secure motor shaft installation\u003c\/li\u003e\n\u003cli data-start=\"1142\" data-end=\"1190\"\u003eRestores proper airflow and heating efficiency\u003c\/li\u003e\n\u003cli data-start=\"1193\" data-end=\"1241\"\u003ePrecision-balanced for smooth, quiet operation\u003c\/li\u003e\n\u003cli data-start=\"1244\" data-end=\"1288\"\u003eBuilt to original equipment specifications\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1290\" data-end=\"1293\"\u003e\n\u003ch1 data-start=\"1444\" data-end=\"1471\"\u003eCompatible Furnace Models\u003c\/h1\u003e\n\u003chr data-start=\"1473\" data-end=\"1476\"\u003e\n\u003ch2 data-start=\"1478\" data-end=\"1506\"\u003e8500-III \u0026amp; 8500-IV Series\u003c\/h2\u003e\n\u003cp data-start=\"1508\" data-end=\"1528\"\u003e8516-III\u003cbr data-start=\"1516\" data-end=\"1519\"\u003e8516-IV\u003c\/p\u003e\n\u003cp data-start=\"1530\" data-end=\"1550\"\u003e8520-III\u003cbr data-start=\"1538\" data-end=\"1541\"\u003e8520-IV\u003c\/p\u003e\n\u003cp data-start=\"1552\" data-end=\"1572\"\u003e8525-III\u003cbr data-start=\"1560\" data-end=\"1563\"\u003e8525-IV\u003c\/p\u003e\n\u003cp data-start=\"1574\" data-end=\"1594\"\u003e8531-III\u003cbr data-start=\"1582\" data-end=\"1585\"\u003e8531-IV\u003c\/p\u003e\n\u003cp data-start=\"1596\" data-end=\"1616\"\u003e8535-III\u003cbr data-start=\"1604\" data-end=\"1607\"\u003e8535-IV\u003c\/p\u003e\n\u003chr data-start=\"1618\" data-end=\"1621\"\u003e\n\u003ch2 data-start=\"1623\" data-end=\"1637\"\u003eAFMD Series\u003c\/h2\u003e\n\u003cp data-start=\"1639\" data-end=\"1683\"\u003eAFMD16\u003cbr data-start=\"1645\" data-end=\"1648\"\u003eAFMD20\u003cbr data-start=\"1654\" data-end=\"1657\"\u003eAFMD25\u003cbr data-start=\"1663\" data-end=\"1666\"\u003eAFMD30\u003cbr data-start=\"1672\" data-end=\"1675\"\u003eAFMD35\u003c\/p\u003e\n\u003chr data-start=\"1685\" data-end=\"1688\"\u003e\n\u003ch2 data-start=\"1690\" data-end=\"1704\"\u003eAFLA Series\u003c\/h2\u003e\n\u003cp data-start=\"1706\" data-end=\"1723\"\u003eAFLA35\u003cbr data-start=\"1712\" data-end=\"1715\"\u003eAFLA40\u003c\/p\u003e\n\u003chr data-start=\"1725\" data-end=\"1728\"\u003e\n\u003ch2 data-start=\"1730\" data-end=\"1744\"\u003eAFLD Series\u003c\/h2\u003e\n\u003cp data-start=\"1746\" data-end=\"1763\"\u003eAFLD35\u003cbr data-start=\"1752\" data-end=\"1755\"\u003eAFLD40\u003c\/p\u003e\n\u003chr data-start=\"1765\" data-end=\"1768\"\u003e\n\u003ch2 data-start=\"1770\" data-end=\"1784\"\u003eDFLA Series\u003c\/h2\u003e\n\u003cp data-start=\"1786\" data-end=\"1803\"\u003eDFLA35\u003cbr data-start=\"1792\" data-end=\"1795\"\u003eDFLA40\u003c\/p\u003e\n\u003chr data-start=\"1805\" data-end=\"1808\"\u003e\n\u003ch2 data-start=\"1810\" data-end=\"1824\"\u003eDFLD Series\u003c\/h2\u003e\n\u003cp data-start=\"1826\" data-end=\"1843\"\u003eDFLD35\u003cbr data-start=\"1832\" data-end=\"1835\"\u003eDFLD40\u003c\/p\u003e\n\u003chr data-start=\"1845\" data-end=\"1848\"\u003e\n\u003ch2 data-start=\"1850\" data-end=\"1864\"\u003eDFMD Series\u003c\/h2\u003e\n\u003cp data-start=\"1866\" data-end=\"1910\"\u003eDFMD16\u003cbr data-start=\"1872\" data-end=\"1875\"\u003eDFMD20\u003cbr data-start=\"1881\" data-end=\"1884\"\u003eDFMD25\u003cbr data-start=\"1890\" data-end=\"1893\"\u003eDFMD30\u003cbr data-start=\"1899\" data-end=\"1902\"\u003eDFMD35\u003c\/p\u003e\n\u003chr data-start=\"1912\" data-end=\"1915\"\u003e\n\u003ch2 data-start=\"1917\" data-end=\"1932\"\u003eDFMDH Series\u003c\/h2\u003e\n\u003cp data-start=\"1934\" data-end=\"1963\"\u003eDFMDH25\u003cbr data-start=\"1941\" data-end=\"1944\"\u003eDFMDH30\u003cbr data-start=\"1951\" data-end=\"1954\"\u003eDFMDH35\u003c\/p\u003e\n\u003chr data-start=\"1965\" data-end=\"1968\"\u003e\n\u003cblockquote data-start=\"1970\" data-end=\"2028\"\u003e\n\u003cp data-start=\"1972\" data-end=\"2028\"\u003eAlways verify your furnace model number before ordering.\u003c\/p\u003e\n\u003c\/blockquote\u003e\n\u003chr data-start=\"1600\" data-end=\"1603\"\u003e\n\u003ch3 data-start=\"1605\" data-end=\"1650\"\u003eWhen Should You Replace the Blower Wheel?\u003c\/h3\u003e\n\u003cp data-start=\"1652\" data-end=\"1712\"\u003eYou may need to replace your blower wheel if you experience:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli data-start=\"1716\" data-end=\"1742\"\u003eReduced interior airflow\u003c\/li\u003e\n\u003cli data-start=\"1745\" data-end=\"1782\"\u003eInconsistent or weak heating output\u003c\/li\u003e\n\u003cli data-start=\"1785\" data-end=\"1827\"\u003eRattling, squealing, or vibration noises\u003c\/li\u003e\n\u003cli data-start=\"1830\" data-end=\"1862\"\u003eVisible blade cracks or damage\u003c\/li\u003e\n\u003cli data-start=\"1865\" data-end=\"1905\"\u003eAirflow-related furnace cycling issues\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"1907\" data-end=\"2006\"\u003eReplacing a worn or damaged blower wheel helps prevent overheating and improves furnace efficiency.\u003c\/p\u003e\n\u003chr data-start=\"2008\" data-end=\"2011\"\u003e\n\u003ch3 data-start=\"2013\" data-end=\"2039\"\u003eProduct Specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli data-start=\"2043\" data-end=\"2079\"\u003e\n\u003cstrong data-start=\"2043\" data-end=\"2060\"\u003eManufacturer:\u003c\/strong\u003e Dometic \/ Atwood\u003c\/li\u003e\n\u003cli data-start=\"2082\" data-end=\"2106\"\u003e\n\u003cstrong data-start=\"2082\" data-end=\"2098\"\u003ePart Number:\u003c\/strong\u003e 33126\u003c\/li\u003e\n\u003cli data-start=\"2109\" data-end=\"2130\"\u003e\n\u003cstrong data-start=\"2109\" data-end=\"2122\"\u003eReplaces:\u003c\/strong\u003e 37764\u003c\/li\u003e\n\u003cli data-start=\"2133\" data-end=\"2173\"\u003e\n\u003cstrong data-start=\"2133\" data-end=\"2150\"\u003eProduct Type:\u003c\/strong\u003e Furnace Blower Wheel\u003c\/li\u003e\n\u003cli data-start=\"2176\" data-end=\"2214\"\u003e\n\u003cstrong data-start=\"2176\" data-end=\"2189\"\u003eIncludes:\u003c\/strong\u003e Blower wheel and clamp\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2278\" data-end=\"2281\"\u003e\n\u003ch2 data-start=\"2283\" data-end=\"2318\"\u003eFrequently Asked Questions (FAQ)\u003c\/h2\u003e\n\u003ch3 data-start=\"2320\" data-end=\"2365\"\u003eQ: What part number does 33126 replace?\u003c\/h3\u003e\n\u003cp data-start=\"2366\" data-end=\"2407\"\u003eA: It replaces OEM part number \u003cstrong data-start=\"2397\" data-end=\"2406\"\u003e37764\u003c\/strong\u003e.\u003c\/p\u003e\n\u003chr data-start=\"2409\" data-end=\"2412\"\u003e\n\u003ch3 data-start=\"2414\" data-end=\"2451\"\u003eQ: Does this include the clamp?\u003c\/h3\u003e\n\u003cp data-start=\"2452\" data-end=\"2518\"\u003eA: Yes. The clamp is included for proper motor shaft installation.\u003c\/p\u003e\n\u003chr data-start=\"2520\" data-end=\"2523\"\u003e\n\u003ch3 data-start=\"2525\" data-end=\"2577\"\u003eQ: Will this fit earlier 8500 series furnaces?\u003c\/h3\u003e\n\u003cp data-start=\"2578\" data-end=\"2683\"\u003eA: It fits 8500 III, 8500 IV, and 8500 LD models. Verify your exact furnace model number before ordering.\u003c\/p\u003e\n\u003chr data-start=\"2685\" data-end=\"2688\"\u003e\n\u003ch3 data-start=\"2690\" data-end=\"2719\"\u003eQ: Is this an OEM part?\u003c\/h3\u003e\n\u003cp data-start=\"2720\" data-end=\"2789\"\u003eA: Yes. 33126 is a genuine Dometic \/ Atwood replacement blower wheel.\u003c\/p\u003e","brand":"RV Furnace Guys","offers":[{"title":"Default Title","offer_id":47854623555825,"sku":null,"price":29.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0784\/4941\/0289\/files\/33126.png?v=1772304015"},{"product_id":"dometic-atwood-33128-furnace-combustion-wheel-8500-8900-series","title":"Dometic \/ Atwood 33128 Furnace Combustion Wheel – 8500, 8900 Series","description":"\u003ch2 data-start=\"134\" data-end=\"207\"\u003eDometic \/ Atwood 33128 Furnace Combustion Wheel – 8500 \u0026amp; 8900 Series\u003c\/h2\u003e\n\u003cp data-start=\"208\" data-end=\"235\"\u003e\u003cstrong data-start=\"208\" data-end=\"235\"\u003eGenuine OEM Replacement\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"237\" data-end=\"306\"\u003e\u003cstrong data-start=\"237\" data-end=\"253\"\u003ePart Number:\u003c\/strong\u003e 33128\u003cbr data-start=\"259\" data-end=\"262\"\u003e\u003cstrong data-start=\"262\" data-end=\"279\"\u003eProduct Type:\u003c\/strong\u003e Furnace Combustion Wheel\u003c\/p\u003e\n\u003chr data-start=\"308\" data-end=\"311\"\u003e\n\u003ch3 data-start=\"313\" data-end=\"333\"\u003eProduct Overview\u003c\/h3\u003e\n\u003cp data-start=\"335\" data-end=\"639\"\u003eThe \u003cstrong data-start=\"339\" data-end=\"390\"\u003eDometic \/ Atwood 33128 Furnace Combustion Wheel\u003c\/strong\u003e is a genuine OEM replacement designed for select \u003cstrong data-start=\"440\" data-end=\"480\"\u003eAtwood 8500 and 8900 series furnaces\u003c\/strong\u003e. The combustion wheel is responsible for drawing in combustion air and expelling exhaust gases, ensuring proper burner operation and safe furnace performance.\u003c\/p\u003e\n\u003cp data-start=\"641\" data-end=\"876\"\u003eA properly functioning combustion wheel maintains correct airflow through the combustion chamber. If cracked, warped, or imbalanced, the furnace may experience ignition failures, poor flame quality, excessive noise, or shutdown issues.\u003c\/p\u003e\n\u003cp data-start=\"878\" data-end=\"1022\"\u003eManufactured to original equipment specifications, Part 33128 restores proper combustion airflow and supports safe, efficient furnace operation.\u003c\/p\u003e\n\u003chr data-start=\"1024\" data-end=\"1027\"\u003e\n\u003ch3 data-start=\"1029\" data-end=\"1045\"\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli data-start=\"1049\" data-end=\"1096\"\u003eGenuine OEM Dometic \/ Atwood replacement part\u003c\/li\u003e\n\u003cli data-start=\"1099\" data-end=\"1143\"\u003eDesigned for 8500 and 8900 series furnaces\u003c\/li\u003e\n\u003cli data-start=\"1146\" data-end=\"1201\"\u003eEnsures proper combustion air intake and exhaust flow\u003c\/li\u003e\n\u003cli data-start=\"1204\" data-end=\"1252\"\u003ePrecision-balanced for smooth, quiet operation\u003c\/li\u003e\n\u003cli data-start=\"1255\" data-end=\"1304\"\u003eDurable construction for high-heat environments\u003c\/li\u003e\n\u003cli data-start=\"1307\" data-end=\"1346\"\u003eBuilt to original equipment standards\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1348\" data-end=\"1351\"\u003e\n\u003ch3 data-start=\"1353\" data-end=\"1382\"\u003eCompatible Furnace Models\u003c\/h3\u003e\n\u003cp data-start=\"1384\" data-end=\"1418\"\u003ePart \u003cstrong data-start=\"1389\" data-end=\"1398\"\u003e33128\u003c\/strong\u003e is compatible with:\u003c\/p\u003e\n\u003cp data-start=\"1420\" data-end=\"1435\"\u003e\u003cstrong data-start=\"1420\" data-end=\"1435\"\u003e8500 Series\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli data-start=\"1438\" data-end=\"1447\"\u003e8500 II\u003c\/li\u003e\n\u003cli data-start=\"1450\" data-end=\"1460\"\u003e8500 III\u003c\/li\u003e\n\u003cli data-start=\"1463\" data-end=\"1472\"\u003e8500 IV\u003c\/li\u003e\n\u003cli data-start=\"1475\" data-end=\"1484\"\u003e8500 LD\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"1486\" data-end=\"1501\"\u003e\u003cstrong data-start=\"1486\" data-end=\"1501\"\u003e8900 Series\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"1502\" data-end=\"1521\"\u003e\n\u003cli data-start=\"1502\" data-end=\"1521\"\u003e\n\u003cp data-start=\"1504\" data-end=\"1521\"\u003eAll 8900 models\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cblockquote data-start=\"1523\" data-end=\"1628\"\u003e\n\u003cp data-start=\"1525\" data-end=\"1628\"\u003eAlways verify your furnace model number on the unit data plate before ordering to ensure compatibility.\u003c\/p\u003e\n\u003c\/blockquote\u003e\n\u003chr data-start=\"1630\" data-end=\"1633\"\u003e\n\u003ch3 data-start=\"1635\" data-end=\"1684\"\u003eWhen Should You Replace the Combustion Wheel?\u003c\/h3\u003e\n\u003cp data-start=\"1686\" data-end=\"1745\"\u003eYou may need to replace the combustion wheel if you notice:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli data-start=\"1749\" data-end=\"1777\"\u003eDelayed or failed ignition\u003c\/li\u003e\n\u003cli data-start=\"1780\" data-end=\"1803\"\u003eUnusual startup noise\u003c\/li\u003e\n\u003cli data-start=\"1806\" data-end=\"1825\"\u003eFurnace vibration\u003c\/li\u003e\n\u003cli data-start=\"1828\" data-end=\"1856\"\u003eInconsistent flame pattern\u003c\/li\u003e\n\u003cli data-start=\"1859\" data-end=\"1887\"\u003eVisible damage or cracking\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"1889\" data-end=\"1994\"\u003eReplacing a worn combustion wheel helps maintain proper draft, combustion efficiency, and safe operation.\u003c\/p\u003e\n\u003chr data-start=\"1996\" data-end=\"1999\"\u003e\n\u003ch3 data-start=\"2001\" data-end=\"2027\"\u003eProduct Specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli data-start=\"2031\" data-end=\"2067\"\u003e\n\u003cstrong data-start=\"2031\" data-end=\"2048\"\u003eManufacturer:\u003c\/strong\u003e Dometic \/ Atwood\u003c\/li\u003e\n\u003cli data-start=\"2070\" data-end=\"2094\"\u003e\n\u003cstrong data-start=\"2070\" data-end=\"2086\"\u003ePart Number:\u003c\/strong\u003e 33128\u003c\/li\u003e\n\u003cli data-start=\"2097\" data-end=\"2130\"\u003e\n\u003cstrong data-start=\"2097\" data-end=\"2111\"\u003eComponent:\u003c\/strong\u003e Combustion Wheel\u003c\/li\u003e\n\u003cli data-start=\"2133\" data-end=\"2198\"\u003e\n\u003cstrong data-start=\"2133\" data-end=\"2155\"\u003eCompatible Series:\u003c\/strong\u003e 8500 II, III, IV, LD and all 8900 models\u003c\/li\u003e\n\u003cli data-start=\"2201\" data-end=\"2238\"\u003e\n\u003cstrong data-start=\"2201\" data-end=\"2214\"\u003eIncludes:\u003c\/strong\u003e Combustion wheel only\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2240\" data-end=\"2243\"\u003e\n\u003ch2 data-start=\"2245\" data-end=\"2280\"\u003eFrequently Asked Questions (FAQ)\u003c\/h2\u003e\n\u003ch3 data-start=\"2282\" data-end=\"2323\"\u003eQ: What does a combustion wheel do?\u003c\/h3\u003e\n\u003cp data-start=\"2324\" data-end=\"2419\"\u003eA: It pulls combustion air into the burner chamber and pushes exhaust gases out of the furnace.\u003c\/p\u003e\n\u003chr data-start=\"2421\" data-end=\"2424\"\u003e\n\u003ch3 data-start=\"2426\" data-end=\"2481\"\u003eQ: Is this the same as the interior blower wheel?\u003c\/h3\u003e\n\u003cp data-start=\"2482\" data-end=\"2597\"\u003eA: No. The combustion wheel handles burner airflow. The blower wheel circulates heated air into the RV living area.\u003c\/p\u003e\n\u003chr data-start=\"2599\" data-end=\"2602\"\u003e\n\u003ch3 data-start=\"2604\" data-end=\"2654\"\u003eQ: Which furnace generations use Part 33128?\u003c\/h3\u003e\n\u003cp data-start=\"2655\" data-end=\"2717\"\u003eA: It fits 8500 II, III, IV, LD, and all 8900 series furnaces.\u003c\/p\u003e\n\u003chr data-start=\"2719\" data-end=\"2722\"\u003e\n\u003ch3 data-start=\"2724\" data-end=\"2753\"\u003eQ: Is this an OEM part?\u003c\/h3\u003e\n\u003cp data-start=\"2754\" data-end=\"2815\"\u003eA: Yes. 33128 is a genuine Dometic \/ Atwood replacement part.\u003c\/p\u003e","brand":"RV Furnace Guys","offers":[{"title":"Default Title","offer_id":47854732640497,"sku":null,"price":14.95,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0784\/4941\/0289\/files\/33128.png?v=1772309831"},{"product_id":"dometic-atwood-31150-furnace-gas-valve-side-outlet-12v-dc","title":"Dometic \/ Atwood 31150 Furnace Gas Valve – Side Outlet – 12V DC","description":"\u003ch2 data-start=\"158\" data-end=\"226\"\u003eDometic \/ Atwood 31150 Furnace Gas Valve – Side Outlet – 12V DC\u003c\/h2\u003e\n\u003cp data-start=\"227\" data-end=\"254\"\u003e\u003cstrong data-start=\"227\" data-end=\"254\"\u003eGenuine OEM Replacement\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"256\" data-end=\"431\"\u003e\u003cstrong data-start=\"256\" data-end=\"272\"\u003ePart Number:\u003c\/strong\u003e 31150\u003cbr data-start=\"278\" data-end=\"281\"\u003e\u003cstrong data-start=\"281\" data-end=\"298\"\u003eProduct Type:\u003c\/strong\u003e Furnace Gas Valve\u003cbr data-start=\"316\" data-end=\"319\"\u003e\u003cstrong data-start=\"319\" data-end=\"331\"\u003eVoltage:\u003c\/strong\u003e 12 Volt DC\u003cbr data-start=\"342\" data-end=\"345\"\u003e\u003cstrong data-start=\"345\" data-end=\"370\"\u003eOutlet Configuration:\u003c\/strong\u003e Side Outlet\u003cbr data-start=\"382\" data-end=\"385\"\u003e\u003cstrong data-start=\"385\" data-end=\"401\"\u003eApplication:\u003c\/strong\u003e Atwood HydroFlame® Furnaces\u003c\/p\u003e\n\u003chr data-start=\"433\" data-end=\"436\"\u003e\n\u003ch3 data-start=\"438\" data-end=\"458\"\u003eProduct Overview\u003c\/h3\u003e\n\u003cp data-start=\"460\" data-end=\"617\"\u003eThe \u003cstrong data-start=\"464\" data-end=\"508\"\u003eDometic \/ Atwood 31150 Furnace Gas Valve\u003c\/strong\u003e is a genuine OEM replacement gas control valve designed for use with select \u003cstrong data-start=\"585\" data-end=\"616\"\u003eAtwood HydroFlame® furnaces\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp data-start=\"619\" data-end=\"928\"\u003eOperating on \u003cstrong data-start=\"632\" data-end=\"646\"\u003e12 Volt DC\u003c\/strong\u003e, this gas valve regulates propane flow to the burner assembly and works in conjunction with the furnace control board to ensure safe ignition and proper heating operation. The \u003cstrong data-start=\"823\" data-end=\"852\"\u003eside outlet configuration\u003c\/strong\u003e allows correct alignment with the burner tube on compatible furnace models.\u003c\/p\u003e\n\u003cp data-start=\"930\" data-end=\"1131\"\u003eA malfunctioning gas valve can cause ignition failure, inconsistent flame, or complete furnace shutdown. Replacing it with OEM Part 31150 restores proper fuel delivery and reliable heating performance.\u003c\/p\u003e\n\u003cp data-start=\"1133\" data-end=\"1263\"\u003eBuilt to original equipment specifications, this valve ensures safe operation and correct fuel flow within your RV heating system.\u003c\/p\u003e\n\u003chr data-start=\"1265\" data-end=\"1268\"\u003e\n\u003ch3 data-start=\"1270\" data-end=\"1286\"\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli data-start=\"1290\" data-end=\"1337\"\u003eGenuine OEM Dometic \/ Atwood replacement part\u003c\/li\u003e\n\u003cli data-start=\"1340\" data-end=\"1382\"\u003eDesigned for Atwood HydroFlame® furnaces\u003c\/li\u003e\n\u003cli data-start=\"1385\" data-end=\"1411\"\u003e\u003cstrong data-start=\"1385\" data-end=\"1409\"\u003e12 Volt DC operation\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli data-start=\"1414\" data-end=\"1445\"\u003e\u003cstrong data-start=\"1414\" data-end=\"1443\"\u003eSide outlet configuration\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli data-start=\"1448\" data-end=\"1496\"\u003eRegulates propane fuel flow to burner assembly\u003c\/li\u003e\n\u003cli data-start=\"1499\" data-end=\"1543\"\u003eEnsures safe and reliable ignition control\u003c\/li\u003e\n\u003cli data-start=\"1546\" data-end=\"1592\"\u003eManufactured to original equipment standards\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1594\" data-end=\"1597\"\u003e\n\u003ch3 data-start=\"1599\" data-end=\"1626\"\u003eCompatible Applications\u003c\/h3\u003e\n\u003cp data-start=\"1628\" data-end=\"1717\"\u003ePart \u003cstrong data-start=\"1633\" data-end=\"1642\"\u003e31150\u003c\/strong\u003e is designed for use with select \u003cstrong data-start=\"1675\" data-end=\"1706\"\u003eAtwood HydroFlame® furnaces\u003c\/strong\u003e utilizing:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli data-start=\"1721\" data-end=\"1737\"\u003e12V DC systems\u003c\/li\u003e\n\u003cli data-start=\"1740\" data-end=\"1777\"\u003eSide outlet gas valve configuration\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cblockquote data-start=\"1779\" data-end=\"1890\"\u003e\n\u003cp data-start=\"1781\" data-end=\"1890\"\u003eAlways verify your furnace model number and gas valve configuration before ordering to ensure proper fitment.\u003c\/p\u003e\n\u003c\/blockquote\u003e\n\u003chr data-start=\"1892\" data-end=\"1895\"\u003e\n\u003ch3 data-start=\"1897\" data-end=\"1939\"\u003eWhen Should You Replace the Gas Valve?\u003c\/h3\u003e\n\u003cp data-start=\"1941\" data-end=\"1997\"\u003eYou may need to replace the gas valve if you experience:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli data-start=\"2001\" data-end=\"2028\"\u003eFurnace failing to ignite\u003c\/li\u003e\n\u003cli data-start=\"2031\" data-end=\"2054\"\u003eNo gas flow to burner\u003c\/li\u003e\n\u003cli data-start=\"2057\" data-end=\"2089\"\u003eIntermittent heating operation\u003c\/li\u003e\n\u003cli data-start=\"2092\" data-end=\"2125\"\u003eIgnition attempts without flame\u003c\/li\u003e\n\u003cli data-start=\"2128\" data-end=\"2164\"\u003eInternal valve sticking or leakage\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"2166\" data-end=\"2234\"\u003eProper gas valve operation is critical for safe furnace performance.\u003c\/p\u003e\n\u003chr data-start=\"2236\" data-end=\"2239\"\u003e\n\u003ch3 data-start=\"2241\" data-end=\"2267\"\u003eProduct Specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli data-start=\"2271\" data-end=\"2307\"\u003e\n\u003cstrong data-start=\"2271\" data-end=\"2288\"\u003eManufacturer:\u003c\/strong\u003e Dometic \/ Atwood\u003c\/li\u003e\n\u003cli data-start=\"2310\" data-end=\"2334\"\u003e\n\u003cstrong data-start=\"2310\" data-end=\"2326\"\u003ePart Number:\u003c\/strong\u003e 31150\u003c\/li\u003e\n\u003cli data-start=\"2337\" data-end=\"2371\"\u003e\n\u003cstrong data-start=\"2337\" data-end=\"2351\"\u003eComponent:\u003c\/strong\u003e Furnace Gas Valve\u003c\/li\u003e\n\u003cli data-start=\"2374\" data-end=\"2399\"\u003e\n\u003cstrong data-start=\"2374\" data-end=\"2386\"\u003eVoltage:\u003c\/strong\u003e 12 Volt DC\u003c\/li\u003e\n\u003cli data-start=\"2402\" data-end=\"2432\"\u003e\n\u003cstrong data-start=\"2402\" data-end=\"2418\"\u003eOutlet Type:\u003c\/strong\u003e Side Outlet\u003c\/li\u003e\n\u003cli data-start=\"2435\" data-end=\"2481\"\u003e\n\u003cstrong data-start=\"2435\" data-end=\"2451\"\u003eApplication:\u003c\/strong\u003e Atwood HydroFlame® Furnaces\u003c\/li\u003e\n\u003cli data-start=\"2484\" data-end=\"2513\"\u003e\n\u003cstrong data-start=\"2484\" data-end=\"2498\"\u003eFuel Type:\u003c\/strong\u003e Propane (LP)\u003c\/li\u003e\n\u003cli data-start=\"2516\" data-end=\"2555\"\u003e\n\u003cstrong data-start=\"2516\" data-end=\"2529\"\u003eIncludes:\u003c\/strong\u003e Gas valve assembly only\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2557\" data-end=\"2560\"\u003e\n\u003ch2 data-start=\"2562\" data-end=\"2597\"\u003eFrequently Asked Questions (FAQ)\u003c\/h2\u003e\n\u003ch3 data-start=\"2599\" data-end=\"2636\"\u003eQ: Is this a 12-volt gas valve?\u003c\/h3\u003e\n\u003cp data-start=\"2637\" data-end=\"2699\"\u003eA: Yes. Part 31150 operates on a 12 Volt DC electrical system.\u003c\/p\u003e\n\u003chr data-start=\"2701\" data-end=\"2704\"\u003e\n\u003ch3 data-start=\"2706\" data-end=\"2744\"\u003eQ: What does “side outlet” mean?\u003c\/h3\u003e\n\u003cp data-start=\"2745\" data-end=\"2860\"\u003eA: The gas outlet port extends from the side of the valve body to align with compatible burner tube configurations.\u003c\/p\u003e\n\u003chr data-start=\"2862\" data-end=\"2865\"\u003e\n\u003ch3 data-start=\"2867\" data-end=\"2921\"\u003eQ: Is this compatible with natural gas furnaces?\u003c\/h3\u003e\n\u003cp data-start=\"2922\" data-end=\"3028\"\u003eA: This valve is designed for LP (propane) furnace systems. Always confirm your fuel type before ordering.\u003c\/p\u003e\n\u003chr data-start=\"3030\" data-end=\"3033\"\u003e\n\u003ch3 data-start=\"3035\" data-end=\"3064\"\u003eQ: Is this an OEM part?\u003c\/h3\u003e\n\u003cp data-start=\"3065\" data-end=\"3131\"\u003eA: Yes. 31150 is a genuine Dometic \/ Atwood replacement gas valve.\u003c\/p\u003e\n\u003chr data-start=\"3133\" data-end=\"3136\"\u003e\n\u003ch3 data-start=\"3138\" data-end=\"3178\"\u003eQ: How do I confirm compatibility?\u003c\/h3\u003e\n\u003cp data-start=\"3179\" data-end=\"3289\"\u003eA: Locate your furnace model number and verify that your existing valve is a 12V DC side-outlet configuration.\u003c\/p\u003e","brand":"RV Furnace Guys","offers":[{"title":"Default Title","offer_id":47854735327473,"sku":null,"price":96.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0784\/4941\/0289\/files\/31150.png?v=1772310697"},{"product_id":"dometic-atwood-32172-furnace-gasket-dsi-ignition-models","title":"Dometic \/ Atwood 32172 Furnace Gasket – DSI Ignition Models","description":"\u003ch2 data-start=\"166\" data-end=\"230\"\u003eDometic \/ Atwood 32172 Furnace Gasket – DSI Ignition Models\u003c\/h2\u003e\n\u003cp data-start=\"231\" data-end=\"258\"\u003e\u003cstrong data-start=\"231\" data-end=\"258\"\u003eGenuine OEM Replacement\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"260\" data-end=\"372\"\u003e\u003cstrong data-start=\"260\" data-end=\"276\"\u003ePart Number:\u003c\/strong\u003e 32172\u003cbr data-start=\"282\" data-end=\"285\"\u003e\u003cstrong data-start=\"285\" data-end=\"302\"\u003eProduct Type:\u003c\/strong\u003e Furnace Gasket\u003cbr data-start=\"317\" data-end=\"320\"\u003e\u003cstrong data-start=\"320\" data-end=\"336\"\u003eApplication:\u003c\/strong\u003e Atwood Furnaces with DSI Ignition\u003c\/p\u003e\n\u003chr data-start=\"374\" data-end=\"377\"\u003e\n\u003ch3 data-start=\"379\" data-end=\"399\"\u003eProduct Overview\u003c\/h3\u003e\n\u003cp data-start=\"401\" data-end=\"575\"\u003eThe \u003cstrong data-start=\"405\" data-end=\"446\"\u003eDometic \/ Atwood 32172 Furnace Gasket\u003c\/strong\u003e is a genuine OEM replacement gasket designed for use with \u003cstrong data-start=\"505\" data-end=\"566\"\u003eAtwood furnaces equipped with DSI (Direct Spark Ignition)\u003c\/strong\u003e systems.\u003c\/p\u003e\n\u003cp data-start=\"577\" data-end=\"863\"\u003eThis gasket provides a secure seal between key furnace components, helping maintain proper combustion airflow and preventing air leakage within the burner chamber area. Maintaining an intact seal is critical for efficient ignition, correct flame performance, and safe furnace operation.\u003c\/p\u003e\n\u003cp data-start=\"865\" data-end=\"1058\"\u003eOver time, gaskets can deteriorate due to heat cycling and vibration. Replacing a worn or damaged gasket with OEM Part 32172 restores proper sealing and supports consistent furnace performance.\u003c\/p\u003e\n\u003cp data-start=\"1060\" data-end=\"1206\"\u003eManufactured to original equipment specifications, this gasket ensures correct fitment and durability in high-temperature RV heating applications.\u003c\/p\u003e\n\u003chr data-start=\"1208\" data-end=\"1211\"\u003e\n\u003ch3 data-start=\"1213\" data-end=\"1229\"\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli data-start=\"1233\" data-end=\"1280\"\u003eGenuine OEM Dometic \/ Atwood replacement part\u003c\/li\u003e\n\u003cli data-start=\"1283\" data-end=\"1331\"\u003eDesigned for Atwood furnaces with DSI ignition\u003c\/li\u003e\n\u003cli data-start=\"1334\" data-end=\"1376\"\u003eMaintains proper combustion chamber seal\u003c\/li\u003e\n\u003cli data-start=\"1379\" data-end=\"1432\"\u003ePrevents air leakage affecting ignition performance\u003c\/li\u003e\n\u003cli data-start=\"1435\" data-end=\"1464\"\u003eHeat-resistant construction\u003c\/li\u003e\n\u003cli data-start=\"1467\" data-end=\"1513\"\u003eManufactured to original equipment standards\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1515\" data-end=\"1518\"\u003e\n\u003ch3 data-start=\"1520\" data-end=\"1547\"\u003eCompatible Applications\u003c\/h3\u003e\n\u003cp data-start=\"1549\" data-end=\"1653\"\u003ePart \u003cstrong data-start=\"1554\" data-end=\"1563\"\u003e32172\u003c\/strong\u003e is compatible with \u003cstrong data-start=\"1583\" data-end=\"1652\"\u003eAtwood furnaces equipped with DSI (Direct Spark Ignition) systems\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cblockquote data-start=\"1655\" data-end=\"1844\"\u003e\n\u003cp data-start=\"1657\" data-end=\"1844\"\u003eImportant: Always verify your furnace ignition type before ordering. This gasket is designed specifically for DSI-equipped models and may not fit standing pilot or gravity-style furnaces.\u003c\/p\u003e\n\u003c\/blockquote\u003e\n\u003cp data-start=\"1846\" data-end=\"1888\"\u003eCommon DSI-equipped series include select:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli data-start=\"1891\" data-end=\"1902\"\u003e79 Series\u003c\/li\u003e\n\u003cli data-start=\"1905\" data-end=\"1916\"\u003e80 Series\u003c\/li\u003e\n\u003cli data-start=\"1919\" data-end=\"1930\"\u003e85 Series\u003c\/li\u003e\n\u003cli data-start=\"1933\" data-end=\"1944\"\u003e89 Series\u003c\/li\u003e\n\u003cli data-start=\"1947\" data-end=\"1965\"\u003eDF Series models\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"1967\" data-end=\"2038\"\u003eAlways confirm your exact furnace model number to ensure compatibility.\u003c\/p\u003e\n\u003chr data-start=\"2040\" data-end=\"2043\"\u003e\n\u003ch3 data-start=\"2045\" data-end=\"2084\"\u003eWhen Should You Replace the Gasket?\u003c\/h3\u003e\n\u003cp data-start=\"2086\" data-end=\"2135\"\u003eYou may need to replace the gasket if you notice:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli data-start=\"2139\" data-end=\"2166\"\u003eRepeated ignition failure\u003c\/li\u003e\n\u003cli data-start=\"2169\" data-end=\"2201\"\u003eImproper flame characteristics\u003c\/li\u003e\n\u003cli data-start=\"2204\" data-end=\"2240\"\u003eAir leakage around burner assembly\u003c\/li\u003e\n\u003cli data-start=\"2243\" data-end=\"2283\"\u003eVisible cracking or compression damage\u003c\/li\u003e\n\u003cli data-start=\"2286\" data-end=\"2331\"\u003eFurnace service requiring component removal\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"2333\" data-end=\"2426\"\u003eReplacing the gasket during routine burner service is recommended to maintain proper sealing.\u003c\/p\u003e\n\u003chr data-start=\"2428\" data-end=\"2431\"\u003e\n\u003ch3 data-start=\"2433\" data-end=\"2459\"\u003eProduct Specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli data-start=\"2463\" data-end=\"2499\"\u003e\n\u003cstrong data-start=\"2463\" data-end=\"2480\"\u003eManufacturer:\u003c\/strong\u003e Dometic \/ Atwood\u003c\/li\u003e\n\u003cli data-start=\"2502\" data-end=\"2526\"\u003e\n\u003cstrong data-start=\"2502\" data-end=\"2518\"\u003ePart Number:\u003c\/strong\u003e 32172\u003c\/li\u003e\n\u003cli data-start=\"2529\" data-end=\"2560\"\u003e\n\u003cstrong data-start=\"2529\" data-end=\"2543\"\u003eComponent:\u003c\/strong\u003e Furnace Gasket\u003c\/li\u003e\n\u003cli data-start=\"2563\" data-end=\"2610\"\u003e\n\u003cstrong data-start=\"2563\" data-end=\"2579\"\u003eApplication:\u003c\/strong\u003e Atwood DSI Ignition Furnaces\u003c\/li\u003e\n\u003cli data-start=\"2613\" data-end=\"2659\"\u003e\n\u003cstrong data-start=\"2613\" data-end=\"2626\"\u003eMaterial:\u003c\/strong\u003e Heat-resistant gasket material\u003c\/li\u003e\n\u003cli data-start=\"2662\" data-end=\"2689\"\u003e\n\u003cstrong data-start=\"2662\" data-end=\"2675\"\u003eIncludes:\u003c\/strong\u003e Gasket only\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2691\" data-end=\"2694\"\u003e\n\u003ch2 data-start=\"2696\" data-end=\"2731\"\u003eFrequently Asked Questions (FAQ)\u003c\/h2\u003e\n\u003ch3 data-start=\"2733\" data-end=\"2761\"\u003eQ: What does DSI mean?\u003c\/h3\u003e\n\u003cp data-start=\"2762\" data-end=\"2898\"\u003eA: DSI stands for Direct Spark Ignition, meaning the furnace ignites the burner electronically rather than using a standing pilot light.\u003c\/p\u003e\n\u003chr data-start=\"2900\" data-end=\"2903\"\u003e\n\u003ch3 data-start=\"2905\" data-end=\"2955\"\u003eQ: Will this fit pilot-light style furnaces?\u003c\/h3\u003e\n\u003cp data-start=\"2956\" data-end=\"3024\"\u003eA: No. This gasket is designed specifically for DSI ignition models.\u003c\/p\u003e\n\u003chr data-start=\"3026\" data-end=\"3029\"\u003e\n\u003ch3 data-start=\"3031\" data-end=\"3060\"\u003eQ: Is this an OEM part?\u003c\/h3\u003e\n\u003cp data-start=\"3061\" data-end=\"3127\"\u003eA: Yes. 32172 is a genuine Dometic \/ Atwood replacement component.\u003c\/p\u003e\n\u003chr data-start=\"3129\" data-end=\"3132\"\u003e\n\u003ch3 data-start=\"3134\" data-end=\"3182\"\u003eQ: When should I replace a furnace gasket?\u003c\/h3\u003e\n\u003cp data-start=\"3183\" data-end=\"3308\"\u003eA: Gaskets should be replaced whenever removed during service or if they show signs of wear, cracking, or heat deterioration.\u003c\/p\u003e","brand":"RV Furnace Guys","offers":[{"title":"Default Title","offer_id":47854737883377,"sku":null,"price":8.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0784\/4941\/0289\/files\/32172.png?v=1772312027"},{"product_id":"dometic-atwood-37022-furnace-limit-switch-8500-iii-8500-iv-8500-ld","title":"Dometic \/ Atwood 37022 Furnace Limit Switch – 8500-III \/ 8500-IV \/ 8500 LD","description":"\u003ch2 data-start=\"167\" data-end=\"246\"\u003eDometic \/ Atwood 37022 Furnace Limit Switch – 8500-III \/ 8500-IV \/ 8500 LD\u003c\/h2\u003e\n\u003cp data-start=\"247\" data-end=\"274\"\u003e\u003cstrong data-start=\"247\" data-end=\"274\"\u003eGenuine OEM Replacement\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"276\" data-end=\"444\"\u003e\u003cstrong data-start=\"276\" data-end=\"292\"\u003ePart Number:\u003c\/strong\u003e 37022\u003cbr data-start=\"298\" data-end=\"301\"\u003e\u003cstrong data-start=\"301\" data-end=\"318\"\u003eProduct Type:\u003c\/strong\u003e Furnace Limit Switch (High Temperature Safety Switch)\u003cbr data-start=\"372\" data-end=\"375\"\u003e\u003cstrong data-start=\"375\" data-end=\"391\"\u003eApplication:\u003c\/strong\u003e Atwood 8500-III, 8500-IV \u0026amp; 8500 LD Series Furnaces\u003c\/p\u003e\n\u003chr data-start=\"446\" data-end=\"449\"\u003e\n\u003ch3 data-start=\"451\" data-end=\"473\"\u003eProduct Overview\u003c\/h3\u003e\n\u003cp data-start=\"475\" data-end=\"653\"\u003eThe \u003cstrong data-start=\"479\" data-end=\"526\"\u003eDometic \/ Atwood 37022 Furnace Limit Switch\u003c\/strong\u003e is a genuine OEM high-temperature safety switch designed for select \u003cstrong data-start=\"595\" data-end=\"652\"\u003eAtwood 8500-III, 8500-IV, and 8500 LD series furnaces\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp data-start=\"655\" data-end=\"896\"\u003eThis limit switch monitors internal furnace temperature and automatically interrupts burner operation if temperatures exceed safe operating levels. It plays a critical role in protecting the heat exchanger and preventing furnace overheating.\u003c\/p\u003e\n\u003cp data-start=\"898\" data-end=\"1151\"\u003eIf your furnace ignites but shuts down quickly, short-cycles once heated, or fails to maintain burner operation, a faulty limit switch may be the cause. Replacing it with OEM Part 37022 restores proper safety protection and reliable heating performance.\u003c\/p\u003e\n\u003cp data-start=\"1153\" data-end=\"1282\"\u003eManufactured to original equipment specifications, this component ensures correct temperature calibration and dependable fitment.\u003c\/p\u003e\n\u003chr data-start=\"1284\" data-end=\"1287\"\u003e\n\u003ch3 data-start=\"1289\" data-end=\"1307\"\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli data-start=\"1311\" data-end=\"1358\"\u003eGenuine OEM Dometic \/ Atwood replacement part\u003c\/li\u003e\n\u003cli data-start=\"1361\" data-end=\"1396\"\u003eHigh-limit overheat safety switch\u003c\/li\u003e\n\u003cli data-start=\"1399\" data-end=\"1450\"\u003eDesigned for 8500-III, 8500-IV and 8500 LD series\u003c\/li\u003e\n\u003cli data-start=\"1453\" data-end=\"1508\"\u003eProtects furnace from excessive internal temperatures\u003c\/li\u003e\n\u003cli data-start=\"1511\" data-end=\"1557\"\u003eRestores safe and reliable heating operation\u003c\/li\u003e\n\u003cli data-start=\"1560\" data-end=\"1606\"\u003eManufactured to original equipment standards\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1608\" data-end=\"1611\"\u003e\n\u003ch3 data-start=\"1613\" data-end=\"1644\"\u003eCompatible Furnace Models\u003c\/h3\u003e\n\u003cp data-start=\"1646\" data-end=\"1680\"\u003ePart \u003cstrong data-start=\"1651\" data-end=\"1660\"\u003e37022\u003c\/strong\u003e is compatible with:\u003c\/p\u003e\n\u003cp data-start=\"1682\" data-end=\"1703\"\u003e\u003cstrong data-start=\"1682\" data-end=\"1701\"\u003e8500-III Series\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli data-start=\"1706\" data-end=\"1716\"\u003e8516-III\u003c\/li\u003e\n\u003cli data-start=\"1719\" data-end=\"1729\"\u003e8520-III\u003c\/li\u003e\n\u003cli data-start=\"1732\" data-end=\"1742\"\u003e8525-III\u003c\/li\u003e\n\u003cli data-start=\"1745\" data-end=\"1755\"\u003e8531-III\u003c\/li\u003e\n\u003cli data-start=\"1758\" data-end=\"1768\"\u003e8535-III\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"1770\" data-end=\"1790\"\u003e\u003cstrong data-start=\"1770\" data-end=\"1788\"\u003e8500-IV Series\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli data-start=\"1793\" data-end=\"1802\"\u003e8516-IV\u003c\/li\u003e\n\u003cli data-start=\"1805\" data-end=\"1814\"\u003e8520-IV\u003c\/li\u003e\n\u003cli data-start=\"1817\" data-end=\"1826\"\u003e8525-IV\u003c\/li\u003e\n\u003cli data-start=\"1829\" data-end=\"1838\"\u003e8531-IV\u003c\/li\u003e\n\u003cli data-start=\"1841\" data-end=\"1850\"\u003e8535-IV\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"1852\" data-end=\"1872\"\u003e\u003cstrong data-start=\"1852\" data-end=\"1870\"\u003e8500 LD Series\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli data-start=\"1875\" data-end=\"1884\"\u003e8516-LD\u003c\/li\u003e\n\u003cli data-start=\"1887\" data-end=\"1896\"\u003e8520-LD\u003c\/li\u003e\n\u003cli data-start=\"1899\" data-end=\"1908\"\u003e8525-LD\u003c\/li\u003e\n\u003cli data-start=\"1911\" data-end=\"1920\"\u003e8531-LD\u003c\/li\u003e\n\u003cli data-start=\"1923\" data-end=\"1932\"\u003e8535-LD\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cblockquote data-start=\"1934\" data-end=\"2032\"\u003e\n\u003cp data-start=\"1936\" data-end=\"2032\"\u003eAlways verify your furnace model on the unit data plate before ordering to ensure compatibility.\u003c\/p\u003e\n\u003c\/blockquote\u003e\n\u003chr data-start=\"2034\" data-end=\"2037\"\u003e\n\u003ch3 data-start=\"2039\" data-end=\"2084\"\u003eWhen Should You Replace the Limit Switch?\u003c\/h3\u003e\n\u003cp data-start=\"2086\" data-end=\"2145\"\u003eYou may need to replace the limit switch if you experience:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli data-start=\"2149\" data-end=\"2194\"\u003eFurnace shutting off shortly after ignition\u003c\/li\u003e\n\u003cli data-start=\"2197\" data-end=\"2221\"\u003eRepeated short cycling\u003c\/li\u003e\n\u003cli data-start=\"2224\" data-end=\"2267\"\u003eBlower running but burner not staying lit\u003c\/li\u003e\n\u003cli data-start=\"2270\" data-end=\"2301\"\u003eOverheat diagnostic condition\u003c\/li\u003e\n\u003cli data-start=\"2304\" data-end=\"2355\"\u003eConfirmed failed switch during electrical testing\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"2357\" data-end=\"2452\"\u003eThe limit switch is a critical safety device and must match your furnace model and calibration.\u003c\/p\u003e\n\u003chr data-start=\"2454\" data-end=\"2457\"\u003e\n\u003ch3 data-start=\"2459\" data-end=\"2487\"\u003eProduct Specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli data-start=\"2491\" data-end=\"2527\"\u003e\n\u003cstrong data-start=\"2491\" data-end=\"2508\"\u003eManufacturer:\u003c\/strong\u003e Dometic \/ Atwood\u003c\/li\u003e\n\u003cli data-start=\"2530\" data-end=\"2554\"\u003e\n\u003cstrong data-start=\"2530\" data-end=\"2546\"\u003ePart Number:\u003c\/strong\u003e 37022\u003c\/li\u003e\n\u003cli data-start=\"2557\" data-end=\"2598\"\u003e\n\u003cstrong data-start=\"2557\" data-end=\"2571\"\u003eComponent:\u003c\/strong\u003e High Limit Safety Switch\u003c\/li\u003e\n\u003cli data-start=\"2601\" data-end=\"2654\"\u003e\n\u003cstrong data-start=\"2601\" data-end=\"2617\"\u003eApplication:\u003c\/strong\u003e 8500-III, 8500-IV \u0026amp; 8500 LD Series\u003c\/li\u003e\n\u003cli data-start=\"2657\" data-end=\"2690\"\u003e\n\u003cstrong data-start=\"2657\" data-end=\"2670\"\u003eIncludes:\u003c\/strong\u003e Limit switch only\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2692\" data-end=\"2695\"\u003e\n\u003ch2 data-start=\"2697\" data-end=\"2732\"\u003eFrequently Asked Questions (FAQ)\u003c\/h2\u003e\n\u003ch3 data-start=\"2734\" data-end=\"2779\"\u003eQ: What does a furnace limit switch do?\u003c\/h3\u003e\n\u003cp data-start=\"2780\" data-end=\"2902\"\u003eA: It protects the furnace from overheating by shutting off burner operation if temperatures exceed safe operating limits.\u003c\/p\u003e\n\u003chr data-start=\"2904\" data-end=\"2907\"\u003e\n\u003ch3 data-start=\"2909\" data-end=\"2949\"\u003eQ: Will this fit 8500-II furnaces?\u003c\/h3\u003e\n\u003cp data-start=\"2950\" data-end=\"3072\"\u003eA: This listing is specifically for 8500-III, 8500-IV, and 8500 LD series models. Always confirm your exact furnace model.\u003c\/p\u003e\n\u003chr data-start=\"3074\" data-end=\"3077\"\u003e\n\u003ch3 data-start=\"3079\" data-end=\"3132\"\u003eQ: Can a bad limit switch cause cycling issues?\u003c\/h3\u003e\n\u003cp data-start=\"3133\" data-end=\"3234\"\u003eA: Yes. A weak or faulty limit switch can cause the furnace to ignite and then shut down prematurely.\u003c\/p\u003e\n\u003chr data-start=\"3236\" data-end=\"3239\"\u003e\n\u003ch3 data-start=\"3241\" data-end=\"3287\"\u003eQ: Is this an OEM Dometic \/ Atwood part?\u003c\/h3\u003e\n\u003cp data-start=\"3288\" data-end=\"3341\"\u003eA: Yes. 37022 is a genuine OEM replacement component.\u003c\/p\u003e","brand":"RV Furnace Guys","offers":[{"title":"Default Title","offer_id":47854805844209,"sku":null,"price":29.95,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0784\/4941\/0289\/files\/37022.png?v=1772314801"},{"product_id":"dometic-atwood-37357-furnace-motor-8531-8535-iii-8900-iii-series","title":"Dometic \/ Atwood 37357 Furnace Motor – 8531\/8535-III \u0026 8900-III Series","description":"\u003ch2 data-start=\"164\" data-end=\"239\"\u003eDometic \/ Atwood 37357 Furnace Motor – 8531\/8535-III \u0026amp; 8900-III Series\u003c\/h2\u003e\n\u003cp data-start=\"240\" data-end=\"267\"\u003e\u003cstrong data-start=\"240\" data-end=\"267\"\u003eGenuine OEM Replacement\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"269\" data-end=\"389\"\u003e\u003cstrong data-start=\"269\" data-end=\"285\"\u003ePart Number:\u003c\/strong\u003e 37357\u003cbr data-start=\"291\" data-end=\"294\"\u003e\u003cstrong data-start=\"294\" data-end=\"311\"\u003eProduct Type:\u003c\/strong\u003e Furnace Motor\u003cbr data-start=\"325\" data-end=\"328\"\u003e\u003cstrong data-start=\"328\" data-end=\"344\"\u003eApplication:\u003c\/strong\u003e Atwood 8500-III \u0026amp; 8900-III Series Furnaces\u003c\/p\u003e\n\u003chr data-start=\"391\" data-end=\"394\"\u003e\n\u003ch2 data-start=\"396\" data-end=\"415\"\u003eProduct Overview\u003c\/h2\u003e\n\u003cp data-start=\"417\" data-end=\"576\"\u003eThe \u003cstrong data-start=\"421\" data-end=\"461\"\u003eDometic \/ Atwood 37357 Furnace Motor\u003c\/strong\u003e is a genuine OEM replacement motor designed for select \u003cstrong data-start=\"517\" data-end=\"575\"\u003eAtwood 8531-III, 8535-III and 8900-III series furnaces\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp data-start=\"578\" data-end=\"774\"\u003eThis motor drives both the combustion air wheel and the interior blower wheel, providing the airflow required for proper ignition, stable combustion, and consistent heat circulation inside the RV.\u003c\/p\u003e\n\u003cp data-start=\"776\" data-end=\"1023\"\u003eIf your furnace does not start, produces loud squealing or grinding noises, or shuts down due to weak airflow, a failing motor may be the cause. Replacing it with OEM Part 37357 restores proper airflow performance and dependable heating operation.\u003c\/p\u003e\n\u003cp data-start=\"1025\" data-end=\"1157\"\u003eManufactured to original equipment specifications, this motor ensures correct RPM, proper airflow balance, and long-term durability.\u003c\/p\u003e\n\u003chr data-start=\"1159\" data-end=\"1162\"\u003e\n\u003ch2 data-start=\"1164\" data-end=\"1179\"\u003eKey Features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli data-start=\"1183\" data-end=\"1230\"\u003eGenuine OEM Dometic \/ Atwood replacement part\u003c\/li\u003e\n\u003cli data-start=\"1233\" data-end=\"1286\"\u003eDesigned for 8531-III, 8535-III \u0026amp; 8900-III furnaces\u003c\/li\u003e\n\u003cli data-start=\"1289\" data-end=\"1341\"\u003ePowers both combustion and interior blower airflow\u003c\/li\u003e\n\u003cli data-start=\"1344\" data-end=\"1381\"\u003eRestores proper ignition sequencing\u003c\/li\u003e\n\u003cli data-start=\"1384\" data-end=\"1423\"\u003eReduces excessive vibration and noise\u003c\/li\u003e\n\u003cli data-start=\"1426\" data-end=\"1465\"\u003eBuilt to original equipment standards\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1467\" data-end=\"1470\"\u003e\n\u003ch2 data-start=\"1472\" data-end=\"1500\"\u003eCompatible Furnace Models\u003c\/h2\u003e\n\u003cp data-start=\"1502\" data-end=\"1536\"\u003ePart \u003cstrong data-start=\"1507\" data-end=\"1516\"\u003e37357\u003c\/strong\u003e is compatible with:\u003c\/p\u003e\n\u003cp data-start=\"1538\" data-end=\"1559\"\u003e\u003cstrong data-start=\"1538\" data-end=\"1557\"\u003e8500-III Series\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli data-start=\"1562\" data-end=\"1572\"\u003e8531-III\u003c\/li\u003e\n\u003cli data-start=\"1575\" data-end=\"1585\"\u003e8535-III\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"1587\" data-end=\"1608\"\u003e\u003cstrong data-start=\"1587\" data-end=\"1606\"\u003e8900-III Series\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli data-start=\"1611\" data-end=\"1621\"\u003e8935-III\u003c\/li\u003e\n\u003cli data-start=\"1624\" data-end=\"1634\"\u003e8940-III\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cblockquote data-start=\"1636\" data-end=\"1714\"\u003e\n\u003cp data-start=\"1638\" data-end=\"1714\"\u003eAlways confirm your exact furnace model from the data plate before ordering.\u003c\/p\u003e\n\u003c\/blockquote\u003e\n\u003chr data-start=\"1716\" data-end=\"1719\"\u003e\n\u003ch2 data-start=\"1721\" data-end=\"1766\"\u003eWhen Should You Replace the Furnace Motor?\u003c\/h2\u003e\n\u003cp data-start=\"1768\" data-end=\"1805\"\u003eYou may need to replace the motor if:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli data-start=\"1809\" data-end=\"1833\"\u003eFurnace fails to start\u003c\/li\u003e\n\u003cli data-start=\"1836\" data-end=\"1861\"\u003eBlower does not operate\u003c\/li\u003e\n\u003cli data-start=\"1864\" data-end=\"1910\"\u003eGrinding, humming, or squealing noises occur\u003c\/li\u003e\n\u003cli data-start=\"1913\" data-end=\"1952\"\u003eWeak airflow causes ignition shutdown\u003c\/li\u003e\n\u003cli data-start=\"1955\" data-end=\"2004\"\u003eFurnace cycles off due to airflow-related fault\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"2006\" data-end=\"2100\"\u003eA properly functioning motor is essential for both combustion safety and proper heat delivery.\u003c\/p\u003e\n\u003chr data-start=\"2102\" data-end=\"2105\"\u003e\n\u003ch2 data-start=\"2107\" data-end=\"2132\"\u003eProduct Specifications\u003c\/h2\u003e\n\u003cp data-start=\"2134\" data-end=\"2295\"\u003eManufacturer: Dometic \/ Atwood\u003cbr data-start=\"2164\" data-end=\"2167\"\u003ePart Number: 37357\u003cbr data-start=\"2185\" data-end=\"2188\"\u003eComponent: Furnace Motor\u003cbr data-start=\"2212\" data-end=\"2215\"\u003eApplication: 8531-III, 8535-III, 8935-III, 8940-III\u003cbr data-start=\"2266\" data-end=\"2269\"\u003eIncludes: Motor assembly\u003c\/p\u003e\n\u003chr data-start=\"2297\" data-end=\"2300\"\u003e\n\u003ch2 data-start=\"2302\" data-end=\"2337\"\u003eFrequently Asked Questions (FAQ)\u003c\/h2\u003e\n\u003cp data-start=\"2339\" data-end=\"2518\"\u003e\u003cstrong data-start=\"2339\" data-end=\"2388\"\u003eQ: Will this fit 8500-IV or 8900-II furnaces?\u003c\/strong\u003e\u003cbr data-start=\"2388\" data-end=\"2391\"\u003eA: This listing is specifically for 8500-III and 8900-III series models. Always verify your furnace generation before ordering.\u003c\/p\u003e\n\u003cp data-start=\"2520\" data-end=\"2630\"\u003e\u003cstrong data-start=\"2520\" data-end=\"2554\"\u003eQ: What does this motor power?\u003c\/strong\u003e\u003cbr data-start=\"2554\" data-end=\"2557\"\u003eA: It drives both the combustion air wheel and the interior blower wheel.\u003c\/p\u003e\n\u003cp data-start=\"2632\" data-end=\"2724\"\u003e\u003cstrong data-start=\"2632\" data-end=\"2659\"\u003eQ: Is this an OEM part?\u003c\/strong\u003e\u003cbr data-start=\"2659\" data-end=\"2662\"\u003eA: Yes. 37357 is a genuine Dometic \/ Atwood replacement motor.\u003c\/p\u003e\n\u003cp data-start=\"2726\" data-end=\"2872\"\u003e\u003cstrong data-start=\"2726\" data-end=\"2772\"\u003eQ: Can insufficient airflow stop ignition?\u003c\/strong\u003e\u003cbr data-start=\"2772\" data-end=\"2775\"\u003eA: Yes. If airflow is not within specification, the furnace safety system may shut down ignition.\u003c\/p\u003e","brand":"RV Furnace Guys","offers":[{"title":"Default Title","offer_id":47857480368369,"sku":null,"price":169.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0784\/4941\/0289\/files\/37357.png?v=1772382943"},{"product_id":"m-c-enterprises-31377mc-furnace-low-air-flow-switch-sail-switch","title":"M.C. Enterprises 31377MC Furnace Low Air Flow Switch (Sail Switch)","description":"\u003ch2 data-start=\"167\" data-end=\"238\"\u003eM.C. Enterprises 31377MC Furnace Low Air Flow Switch (Sail Switch)\u003c\/h2\u003e\n\u003cp data-start=\"239\" data-end=\"293\"\u003e\u003cstrong data-start=\"239\" data-end=\"293\"\u003eAftermarket Replacement for Dometic \/ Atwood 31377\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"295\" data-end=\"478\"\u003e\u003cstrong data-start=\"295\" data-end=\"311\"\u003ePart Number:\u003c\/strong\u003e 31377MC\u003cbr data-start=\"319\" data-end=\"322\"\u003e\u003cstrong data-start=\"322\" data-end=\"335\"\u003eReplaces:\u003c\/strong\u003e Dometic \/ Atwood 31377\u003cbr data-start=\"358\" data-end=\"361\"\u003e\u003cstrong data-start=\"361\" data-end=\"378\"\u003eProduct Type:\u003c\/strong\u003e Furnace Low Air Flow Switch (Sail Switch)\u003cbr data-start=\"420\" data-end=\"423\"\u003e\u003cstrong data-start=\"423\" data-end=\"439\"\u003eApplication:\u003c\/strong\u003e Atwood \u0026amp; Dometic HydroFlame Furnaces\u003c\/p\u003e\n\u003chr data-start=\"480\" data-end=\"483\"\u003e\n\u003ch2 data-start=\"485\" data-end=\"504\"\u003eProduct Overview\u003c\/h2\u003e\n\u003cp data-start=\"506\" data-end=\"665\"\u003eThe \u003cstrong data-start=\"510\" data-end=\"566\"\u003eM.C. Enterprises 31377MC Furnace Low Air Flow Switch\u003c\/strong\u003e is a high-quality aftermarket replacement designed to replace \u003cstrong data-start=\"629\" data-end=\"664\"\u003eDometic \/ Atwood OEM Part 31377\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp data-start=\"667\" data-end=\"900\"\u003eAlso known as a \u003cstrong data-start=\"683\" data-end=\"698\"\u003esail switch\u003c\/strong\u003e, this component verifies adequate blower airflow before permitting the furnace ignition sequence. If proper airflow is not detected, the switch prevents ignition to protect against improper combustion.\u003c\/p\u003e\n\u003cp data-start=\"902\" data-end=\"1066\"\u003eIf your RV furnace blower runs but the burner will not ignite, cycles erratically, or shuts down prematurely, a failed sail switch is one of the most common causes.\u003c\/p\u003e\n\u003cp data-start=\"1068\" data-end=\"1224\"\u003eReplacing your original 31377 sail switch with the 31377MC restores proper ignition sequencing, stable airflow monitoring, and reliable heating performance.\u003c\/p\u003e\n\u003cp data-start=\"1226\" data-end=\"1390\"\u003eManufactured by M.C. Enterprises, this component provides dependable performance and direct-fit compatibility for a wide range of Atwood and Dometic furnace models.\u003c\/p\u003e\n\u003chr data-start=\"1392\" data-end=\"1395\"\u003e\n\u003ch2 data-start=\"1397\" data-end=\"1412\"\u003eKey Features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli data-start=\"1416\" data-end=\"1475\"\u003eDirect aftermarket replacement for Dometic \/ Atwood 31377\u003c\/li\u003e\n\u003cli data-start=\"1478\" data-end=\"1512\"\u003eVerifies airflow before ignition\u003c\/li\u003e\n\u003cli data-start=\"1515\" data-end=\"1563\"\u003eHelps resolve “blower runs but no heat” issues\u003c\/li\u003e\n\u003cli data-start=\"1566\" data-end=\"1603\"\u003eRestores proper ignition sequencing\u003c\/li\u003e\n\u003cli data-start=\"1606\" data-end=\"1655\"\u003eDirect-fit design for compatible furnace models\u003c\/li\u003e\n\u003cli data-start=\"1658\" data-end=\"1693\"\u003eCost-effective alternative to OEM\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1695\" data-end=\"1698\"\u003e\n\u003ch1 data-start=\"1700\" data-end=\"1727\"\u003eCompatible Furnace Models\u003c\/h1\u003e\n\u003chr data-start=\"1729\" data-end=\"1732\"\u003e\n\u003ch2 data-start=\"1734\" data-end=\"1758\"\u003e7900 \u0026amp; 7900-II Series\u003c\/h2\u003e\n\u003cp data-start=\"1760\" data-end=\"1776\"\u003e7912\u003cbr data-start=\"1764\" data-end=\"1767\"\u003e7912-II\u003c\/p\u003e\n\u003cp data-start=\"1778\" data-end=\"1794\"\u003e7916\u003cbr data-start=\"1782\" data-end=\"1785\"\u003e7916-II\u003c\/p\u003e\n\u003cp data-start=\"1796\" data-end=\"1812\"\u003e7920\u003cbr data-start=\"1800\" data-end=\"1803\"\u003e7920-II\u003c\/p\u003e\n\u003chr data-start=\"1814\" data-end=\"1817\"\u003e\n\u003ch2 data-start=\"1819\" data-end=\"1833\"\u003e8500 Series\u003c\/h2\u003e\n\u003cp data-start=\"1835\" data-end=\"1872\"\u003e8516\u003cbr data-start=\"1839\" data-end=\"1842\"\u003e8516-II\u003cbr data-start=\"1849\" data-end=\"1852\"\u003e8516-III\u003cbr data-start=\"1860\" data-end=\"1863\"\u003e8516-IV\u003c\/p\u003e\n\u003cp data-start=\"1874\" data-end=\"1911\"\u003e8520\u003cbr data-start=\"1878\" data-end=\"1881\"\u003e8520-II\u003cbr data-start=\"1888\" data-end=\"1891\"\u003e8520-III\u003cbr data-start=\"1899\" data-end=\"1902\"\u003e8520-IV\u003c\/p\u003e\n\u003cp data-start=\"1913\" data-end=\"1950\"\u003e8525\u003cbr data-start=\"1917\" data-end=\"1920\"\u003e8525-II\u003cbr data-start=\"1927\" data-end=\"1930\"\u003e8525-III\u003cbr data-start=\"1938\" data-end=\"1941\"\u003e8525-IV\u003c\/p\u003e\n\u003cp data-start=\"1952\" data-end=\"1989\"\u003e8531\u003cbr data-start=\"1956\" data-end=\"1959\"\u003e8531-II\u003cbr data-start=\"1966\" data-end=\"1969\"\u003e8531-III\u003cbr data-start=\"1977\" data-end=\"1980\"\u003e8531-IV\u003c\/p\u003e\n\u003cp data-start=\"1991\" data-end=\"2028\"\u003e8535\u003cbr data-start=\"1995\" data-end=\"1998\"\u003e8535-II\u003cbr data-start=\"2005\" data-end=\"2008\"\u003e8535-III\u003cbr data-start=\"2016\" data-end=\"2019\"\u003e8535-IV\u003c\/p\u003e\n\u003chr data-start=\"2030\" data-end=\"2033\"\u003e\n\u003ch2 data-start=\"2035\" data-end=\"2049\"\u003e8900 Series\u003c\/h2\u003e\n\u003ch3 data-start=\"2051\" data-end=\"2066\"\u003e8935 Models\u003c\/h3\u003e\n\u003cp data-start=\"2067\" data-end=\"2144\"\u003e8935-DC-I\u003cbr data-start=\"2076\" data-end=\"2079\"\u003e8935-AC-I\u003cbr data-start=\"2088\" data-end=\"2091\"\u003e8935-DC-II\u003cbr data-start=\"2101\" data-end=\"2104\"\u003e8935-AC-II\u003cbr data-start=\"2114\" data-end=\"2117\"\u003e8935-DC-III\u003cbr data-start=\"2128\" data-end=\"2131\"\u003e8935-AC-III\u003c\/p\u003e\n\u003ch3 data-start=\"2146\" data-end=\"2161\"\u003e8940 Models\u003c\/h3\u003e\n\u003cp data-start=\"2162\" data-end=\"2239\"\u003e8940-DC-I\u003cbr data-start=\"2171\" data-end=\"2174\"\u003e8940-AC-I\u003cbr data-start=\"2183\" data-end=\"2186\"\u003e8940-DC-II\u003cbr data-start=\"2196\" data-end=\"2199\"\u003e8940-AC-II\u003cbr data-start=\"2209\" data-end=\"2212\"\u003e8940-DC-III\u003cbr data-start=\"2223\" data-end=\"2226\"\u003e8940-AC-III\u003c\/p\u003e\n\u003chr data-start=\"2241\" data-end=\"2244\"\u003e\n\u003cblockquote data-start=\"2246\" data-end=\"2346\"\u003e\n\u003cp data-start=\"2248\" data-end=\"2346\"\u003eAlways verify your furnace model number and confirm it originally used Part 31377 before ordering.\u003c\/p\u003e\n\u003c\/blockquote\u003e\n\u003chr data-start=\"2348\" data-end=\"2351\"\u003e\n\u003ch2 data-start=\"2353\" data-end=\"2396\"\u003eWhen Should You Replace the Sail Switch?\u003c\/h2\u003e\n\u003cp data-start=\"2398\" data-end=\"2441\"\u003eYou may need to replace the sail switch if:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli data-start=\"2445\" data-end=\"2491\"\u003eBlower motor runs but burner does not ignite\u003c\/li\u003e\n\u003cli data-start=\"2494\" data-end=\"2537\"\u003eFurnace attempts ignition then shuts down\u003c\/li\u003e\n\u003cli data-start=\"2540\" data-end=\"2565\"\u003eHeating is intermittent\u003c\/li\u003e\n\u003cli data-start=\"2568\" data-end=\"2601\"\u003eAirflow-related shutdown occurs\u003c\/li\u003e\n\u003cli data-start=\"2604\" data-end=\"2644\"\u003ePaddle is stuck, bent, or contaminated\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"2646\" data-end=\"2725\"\u003eThe sail switch is one of the most common service parts in HydroFlame furnaces.\u003c\/p\u003e\n\u003chr data-start=\"2727\" data-end=\"2730\"\u003e\n\u003ch2 data-start=\"2732\" data-end=\"2757\"\u003eProduct Specifications\u003c\/h2\u003e\n\u003cp data-start=\"2759\" data-end=\"2978\"\u003eManufacturer: M.C. Enterprises\u003cbr data-start=\"2789\" data-end=\"2792\"\u003ePart Number: 31377MC\u003cbr data-start=\"2812\" data-end=\"2815\"\u003eReplaces: Dometic \/ Atwood 31377\u003cbr data-start=\"2847\" data-end=\"2850\"\u003eComponent: Low Air Flow Switch (Sail Switch)\u003cbr data-start=\"2894\" data-end=\"2897\"\u003eApplication: 7900, 8500 \u0026amp; 8900 Series Furnaces\u003cbr data-start=\"2943\" data-end=\"2946\"\u003eIncludes: Sail switch assembly\u003c\/p\u003e\n\u003chr data-start=\"2980\" data-end=\"2983\"\u003e\n\u003ch2 data-start=\"2985\" data-end=\"3020\"\u003eFrequently Asked Questions (FAQ)\u003c\/h2\u003e\n\u003cp data-start=\"3022\" data-end=\"3164\"\u003e\u003cstrong data-start=\"3022\" data-end=\"3057\"\u003eQ: Is this an OEM Dometic part?\u003c\/strong\u003e\u003cbr data-start=\"3057\" data-end=\"3060\"\u003eA: No. This is an aftermarket replacement manufactured by M.C. Enterprises that replaces OEM part 31377.\u003c\/p\u003e\n\u003cp data-start=\"3166\" data-end=\"3272\"\u003e\u003cstrong data-start=\"3166\" data-end=\"3200\"\u003eQ: What does a sail switch do?\u003c\/strong\u003e\u003cbr data-start=\"3200\" data-end=\"3203\"\u003eA: It confirms adequate airflow before allowing the burner to ignite.\u003c\/p\u003e\n\u003cp data-start=\"3274\" data-end=\"3422\"\u003e\u003cstrong data-start=\"3274\" data-end=\"3348\"\u003eQ: Will this fix a furnace where the blower runs but no flame appears?\u003c\/strong\u003e\u003cbr data-start=\"3348\" data-end=\"3351\"\u003eA: A failed sail switch is one of the most common causes of that issue.\u003c\/p\u003e\n\u003cp data-start=\"3424\" data-end=\"3573\"\u003e\u003cstrong data-start=\"3424\" data-end=\"3477\"\u003eQ: Is this compatible with both AC and DC models?\u003c\/strong\u003e\u003cbr data-start=\"3477\" data-end=\"3480\"\u003eA: Yes, as listed above, it fits applicable AC and DC 8900 models that originally used 31377.\u003c\/p\u003e","brand":"RV Furnace Guys","offers":[{"title":"Default Title","offer_id":47857554161905,"sku":null,"price":12.49,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0784\/4941\/0289\/files\/31377sailswitchMC.jpg?v=1772392704"},{"product_id":"dometic-atwood-33780-rv-furnace-circuit-breaker-7-amp-pop-up-reset-8500-series","title":"Dometic \/ Atwood 33780 RV Furnace Circuit Breaker – 7 Amp Pop-Up Reset - 8500 Series - Special Order","description":"\u003ch1 data-end=\"251\" data-start=\"182\" data-section-id=\"evsw9g\"\u003eDometic \/ Atwood 33780 Furnace Circuit Breaker – 7 Amp Pop-Up Reset\u003c\/h1\u003e\n\u003cp\u003e\u003cstrong data-start=\"283\" data-end=\"339\"\u003eSpecial Order Item (7–14 Business Days for Shipping)\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-end=\"518\" data-start=\"253\"\u003eProtect your RV furnace electrical system with the \u003cstrong data-end=\"354\" data-start=\"304\"\u003eDometic \/ Atwood 33780 Furnace Circuit Breaker\u003c\/strong\u003e. This \u003cstrong data-end=\"391\" data-start=\"361\"\u003e7-amp pop-up style breaker\u003c\/strong\u003e is designed to protect the furnace blower motor and electrical components from excessive current draw and electrical overload.\u003c\/p\u003e\n\u003cp data-end=\"790\" data-start=\"520\"\u003eWhen an abnormal power spike or electrical fault occurs, the breaker \u003cstrong data-end=\"625\" data-start=\"589\"\u003etrips and interrupts the circuit\u003c\/strong\u003e, preventing damage to critical furnace components. Once the issue is resolved, the breaker can be \u003cstrong data-end=\"757\" data-start=\"724\"\u003ereset using the pop-up button\u003c\/strong\u003e, restoring power to the furnace.\u003c\/p\u003e\n\u003cp data-end=\"959\" data-start=\"792\"\u003eThis breaker is commonly used in \u003cstrong data-end=\"856\" data-start=\"825\"\u003eAtwood Hydro Flame furnaces\u003c\/strong\u003e and helps ensure safe and reliable furnace operation in your RV.\u003c\/p\u003e\n\u003cp data-end=\"959\" data-start=\"792\"\u003e\u003cstrong data-start=\"1086\" data-end=\"1102\"\u003ePlease Note:\u003c\/strong\u003e This item is a \u003cem data-start=\"1118\" data-end=\"1133\"\u003eSpecial Order\u003c\/em\u003e part and typically ships within \u003cstrong data-start=\"1166\" data-end=\"1188\"\u003e7–14 business days\u003c\/strong\u003e.\u003c\/p\u003e\n\u003chr data-end=\"964\" data-start=\"961\"\u003e\n\u003ch2 data-end=\"981\" data-start=\"966\" data-section-id=\"1ma7m6t\"\u003eKey Features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli data-end=\"1038\" data-start=\"985\"\u003eGenuine \u003cstrong data-end=\"1038\" data-start=\"993\"\u003eDometic \/ Atwood furnace replacement part\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1066\" data-start=\"1041\"\u003e\u003cstrong data-end=\"1066\" data-start=\"1041\"\u003e7 Amp circuit breaker\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli data-end=\"1116\" data-start=\"1069\"\u003e\n\u003cstrong data-end=\"1091\" data-start=\"1069\"\u003ePop-up reset style\u003c\/strong\u003e for easy troubleshooting\u003c\/li\u003e\n\u003cli data-end=\"1174\" data-start=\"1119\"\u003eProtects furnace blower motor and electrical components\u003c\/li\u003e\n\u003cli data-end=\"1228\" data-start=\"1177\"\u003eDesigned for \u003cstrong data-end=\"1228\" data-start=\"1190\"\u003eAtwood Hydro Flame furnace systems\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1291\" data-start=\"1231\"\u003eCompact and durable construction for RV furnace applications\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-end=\"1296\" data-start=\"1293\"\u003e\n\u003ch2 data-end=\"1326\" data-start=\"1298\" data-section-id=\"18dvupj\"\u003eCompatible Furnace Models\u003c\/h2\u003e\n\u003cp data-end=\"1423\" data-start=\"1328\"\u003eThe \u003cstrong data-end=\"1374\" data-start=\"1332\"\u003eDometic \/ Atwood 33780 circuit breaker\u003c\/strong\u003e is compatible with the following furnace models:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli data-end=\"1437\" data-start=\"1427\"\u003e\u003cstrong data-end=\"1437\" data-start=\"1427\"\u003e8525-I\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli data-end=\"1451\" data-start=\"1440\"\u003e\u003cstrong data-end=\"1451\" data-start=\"1440\"\u003e8525-II\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli data-end=\"1466\" data-start=\"1454\"\u003e\u003cstrong data-end=\"1466\" data-start=\"1454\"\u003e8516-III\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli data-end=\"1481\" data-start=\"1469\"\u003e\u003cstrong data-end=\"1481\" data-start=\"1469\"\u003e8520-III\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-end=\"1627\" data-start=\"1483\"\u003eThis breaker is also used across multiple \u003cstrong data-end=\"1562\" data-start=\"1525\"\u003eAtwood Hydro Flame furnace series\u003c\/strong\u003e in similar configurations. \u003cspan data-state=\"closed\" class=\"\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-end=\"1679\" data-start=\"1629\"\u003eAlways confirm your furnace model before ordering.\u003c\/p\u003e\n\u003chr data-end=\"1684\" data-start=\"1681\"\u003e\n\u003ch2 data-end=\"1708\" data-start=\"1686\" data-section-id=\"zte05f\"\u003eWhat This Part Does\u003c\/h2\u003e\n\u003cp data-end=\"2034\" data-start=\"1710\"\u003eThe \u003cstrong data-end=\"1747\" data-start=\"1714\"\u003e33780 furnace circuit breaker\u003c\/strong\u003e protects the furnace electrical system by monitoring current flow to the blower motor. If the system draws too much current for an extended period, the breaker \u003cstrong data-end=\"1945\" data-start=\"1908\"\u003etrips to stop the electrical flow\u003c\/strong\u003e, preventing damage to internal furnace components. \u003cspan data-state=\"closed\" class=\"\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-end=\"2146\" data-start=\"2036\"\u003eAfter the issue is corrected, simply \u003cstrong data-end=\"2099\" data-start=\"2073\"\u003epress the reset button\u003c\/strong\u003e to restore power and resume furnace operation.\u003c\/p\u003e\n\u003chr data-end=\"2151\" data-start=\"2148\"\u003e\n\u003ch2 data-end=\"2204\" data-start=\"2153\" data-section-id=\"6qv7jr\"\u003eSigns You May Need a New Furnace Circuit Breaker\u003c\/h2\u003e\n\u003cp data-end=\"2273\" data-start=\"2206\"\u003eYou may need to replace the \u003cstrong data-end=\"2258\" data-start=\"2234\"\u003eAtwood 33780 breaker\u003c\/strong\u003e if you notice:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli data-end=\"2306\" data-start=\"2277\"\u003eFurnace blower will not start\u003c\/li\u003e\n\u003cli data-end=\"2343\" data-start=\"2309\"\u003eFurnace loses power intermittently\u003c\/li\u003e\n\u003cli data-end=\"2370\" data-start=\"2346\"\u003eBreaker repeatedly trips\u003c\/li\u003e\n\u003cli data-end=\"2401\" data-start=\"2373\"\u003eFurnace stops during startup\u003c\/li\u003e\n\u003cli data-end=\"2441\" data-start=\"2404\"\u003eVisible damage or wear on the breaker\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-end=\"2554\" data-start=\"2443\"\u003eReplacing a faulty breaker can help restore reliable furnace operation and protect other electrical components.\u003c\/p\u003e\n\u003chr data-end=\"2559\" data-start=\"2556\"\u003e\n\u003ch2 data-end=\"2582\" data-start=\"2561\" data-section-id=\"16dprsq\"\u003eInstallation Notes\u003c\/h2\u003e\n\u003cp data-end=\"2765\" data-start=\"2584\"\u003eThe \u003cstrong data-end=\"2613\" data-start=\"2588\"\u003e33780 circuit breaker\u003c\/strong\u003e is typically mounted externally on the furnace and wired into the furnace electrical circuit. Disconnect power before servicing any furnace components.\u003c\/p\u003e\n\u003cp data-end=\"2839\" data-start=\"2767\"\u003eIf you are unsure about installation, consult a qualified RV technician.\u003c\/p\u003e\n\u003chr data-end=\"2844\" data-start=\"2841\"\u003e\n\u003ch2 data-end=\"2875\" data-start=\"2846\" data-section-id=\"1r8frcv\"\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003cp data-end=\"2963\" data-start=\"2877\"\u003e\u003cstrong data-end=\"2923\" data-start=\"2877\"\u003eWhat amperage is the Atwood 33780 breaker?\u003c\/strong\u003e\u003cbr data-end=\"2926\" data-start=\"2923\"\u003eThis breaker is rated for \u003cstrong data-end=\"2962\" data-start=\"2952\"\u003e7 amps\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp data-end=\"3047\" data-start=\"2965\"\u003e\u003cstrong data-end=\"2998\" data-start=\"2965\"\u003eIs this a resettable breaker?\u003c\/strong\u003e\u003cbr data-end=\"3001\" data-start=\"2998\"\u003eYes. It uses a \u003cstrong data-end=\"3046\" data-start=\"3016\"\u003emanual pop-up reset button\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp data-end=\"3174\" data-start=\"3049\"\u003e\u003cstrong data-end=\"3084\" data-start=\"3049\"\u003eWhat does this breaker protect?\u003c\/strong\u003e\u003cbr data-end=\"3087\" data-start=\"3084\"\u003eIt protects the \u003cstrong data-end=\"3150\" data-start=\"3103\"\u003efurnace blower motor and electrical circuit\u003c\/strong\u003e from excessive current.\u003c\/p\u003e\n\u003cp data-end=\"3337\" data-start=\"3176\"\u003e\u003cstrong data-end=\"3227\" data-start=\"3176\"\u003eCan a tripped breaker indicate another problem?\u003c\/strong\u003e\u003cbr data-end=\"3230\" data-start=\"3227\"\u003eYes. A breaker usually trips because of \u003cstrong data-end=\"3336\" data-start=\"3270\"\u003eexcessive motor draw, wiring issues, or a failing blower motor\u003c\/strong\u003e.\u003c\/p\u003e\n\u003chr data-end=\"3342\" data-start=\"3339\"\u003e\n\u003ch2 data-end=\"3378\" data-start=\"3344\" data-section-id=\"1n9sz8f\"\u003eWhy Buy From RVFurnaceGuys.com?\u003c\/h2\u003e\n\u003cp data-end=\"3627\" data-start=\"3380\"\u003eAt \u003cstrong data-end=\"3404\" data-start=\"3383\"\u003eRVFurnaceGuys.com\u003c\/strong\u003e, we specialize exclusively in \u003cstrong data-end=\"3477\" data-start=\"3435\"\u003eRV furnace parts and repair components\u003c\/strong\u003e. Our goal is to help RV owners and technicians quickly diagnose furnace issues and get heating systems running again with reliable replacement parts.\u003c\/p\u003e","brand":"RV Furnace Guys","offers":[{"title":"Default Title","offer_id":47879790067953,"sku":null,"price":39.95,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0784\/4941\/0289\/files\/33780.jpg?v=1772900094"},{"product_id":"m-c-enterprises-36999mc-igniter-electrode-dual-sense-replacement-for-atwood-rv-furnaces-8500-series","title":"M.C. Enterprises 36999MC Igniter Electrode – Dual Sense Replacement for Atwood RV Furnaces - 8500 Series","description":"\u003ch1 data-section-id=\"jtizpo\" data-start=\"178\" data-end=\"270\"\u003eM.C. Enterprises 36999MC Igniter Electrode – Dual Sense Replacement for Atwood RV Furnaces\u003c\/h1\u003e\n\u003cp data-start=\"272\" data-end=\"594\"\u003eRestore reliable ignition in your RV furnace with the \u003cstrong data-start=\"326\" data-end=\"372\"\u003eM.C. Enterprises 36999MC Igniter Electrode\u003c\/strong\u003e. This \u003cstrong data-start=\"379\" data-end=\"411\"\u003edual-sense igniter electrode\u003c\/strong\u003e is designed as a replacement for many popular \u003cstrong data-start=\"458\" data-end=\"492\"\u003eAtwood Hydro Flame RV furnaces\u003c\/strong\u003e, providing both \u003cstrong data-start=\"509\" data-end=\"545\"\u003espark ignition and flame sensing\u003c\/strong\u003e to ensure safe and consistent furnace operation.\u003c\/p\u003e\n\u003cp data-start=\"596\" data-end=\"883\"\u003eWhen the furnace calls for heat, the igniter electrode generates the spark needed to ignite the propane burner while also sensing the burner flame. If the igniter becomes cracked, worn, or coated with carbon buildup, the furnace may fail to ignite or may shut down shortly after startup.\u003c\/p\u003e\n\u003cp data-start=\"885\" data-end=\"1052\"\u003eReplacing a worn igniter with the \u003cstrong data-start=\"919\" data-end=\"940\"\u003e36999MC electrode\u003c\/strong\u003e is one of the most common repairs for \u003cstrong data-start=\"979\" data-end=\"1051\"\u003eRV furnaces that won’t ignite or repeatedly shut down during startup\u003c\/strong\u003e.\u003c\/p\u003e\n\u003chr data-start=\"1054\" data-end=\"1057\"\u003e\n\u003ch2 data-section-id=\"1ma7m6t\" data-start=\"1059\" data-end=\"1074\"\u003eKey Features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli data-start=\"1078\" data-end=\"1128\"\u003e\u003cstrong data-start=\"1078\" data-end=\"1128\"\u003eM.C. Enterprises replacement igniter electrode\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli data-start=\"1131\" data-end=\"1196\"\u003e\n\u003cstrong data-start=\"1131\" data-end=\"1152\"\u003eDual-sense design\u003c\/strong\u003e provides ignition spark and flame detection\u003c\/li\u003e\n\u003cli data-start=\"1199\" data-end=\"1254\"\u003eReplacement for many \u003cstrong data-start=\"1220\" data-end=\"1254\"\u003eAtwood Hydro Flame RV furnaces\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1257\" data-end=\"1296\"\u003eHelps restore reliable furnace ignition\u003c\/li\u003e\n\u003cli data-start=\"1299\" data-end=\"1355\"\u003eDurable design for high-temperature furnace environments\u003c\/li\u003e\n\u003cli data-start=\"1358\" data-end=\"1413\"\u003eDirect replacement for worn or damaged furnace igniters\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1415\" data-end=\"1418\"\u003e\n\u003ch2 data-section-id=\"18dvupj\" data-start=\"1420\" data-end=\"1448\"\u003eCompatible Furnace Models\u003c\/h2\u003e\n\u003cp data-start=\"1450\" data-end=\"1549\"\u003eThe \u003cstrong data-start=\"1454\" data-end=\"1500\"\u003eM.C. Enterprises 36999MC Igniter Electrode\u003c\/strong\u003e is compatible with the following furnace models:\u003c\/p\u003e\n\u003ch3 data-section-id=\"l4ms53\" data-start=\"1551\" data-end=\"1566\"\u003e8516 Series\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli data-start=\"1569\" data-end=\"1577\"\u003e8516-I\u003c\/li\u003e\n\u003cli data-start=\"1580\" data-end=\"1589\"\u003e8516-II\u003c\/li\u003e\n\u003cli data-start=\"1592\" data-end=\"1602\"\u003e8516-III\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"8gjjea\" data-start=\"1604\" data-end=\"1619\"\u003e8520 Series\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli data-start=\"1622\" data-end=\"1630\"\u003e8520-I\u003c\/li\u003e\n\u003cli data-start=\"1633\" data-end=\"1642\"\u003e8520-II\u003c\/li\u003e\n\u003cli data-start=\"1645\" data-end=\"1655\"\u003e8520-III\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"95juzb\" data-start=\"1657\" data-end=\"1672\"\u003e8525 Series\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli data-start=\"1675\" data-end=\"1683\"\u003e8525-I\u003c\/li\u003e\n\u003cli data-start=\"1686\" data-end=\"1695\"\u003e8525-II\u003c\/li\u003e\n\u003cli data-start=\"1698\" data-end=\"1708\"\u003e8525-III\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"1su1j0y\" data-start=\"1710\" data-end=\"1725\"\u003e8531 Series\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli data-start=\"1728\" data-end=\"1736\"\u003e8531-I\u003c\/li\u003e\n\u003cli data-start=\"1739\" data-end=\"1748\"\u003e8531-II\u003c\/li\u003e\n\u003cli data-start=\"1751\" data-end=\"1761\"\u003e8531-III\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"16rkjyu\" data-start=\"1763\" data-end=\"1778\"\u003e8535 Series\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli data-start=\"1781\" data-end=\"1789\"\u003e8535-I\u003c\/li\u003e\n\u003cli data-start=\"1792\" data-end=\"1801\"\u003e8535-II\u003c\/li\u003e\n\u003cli data-start=\"1804\" data-end=\"1814\"\u003e8535-III\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"1816\" data-end=\"1889\"\u003eAlways verify your furnace model before ordering to ensure compatibility.\u003c\/p\u003e\n\u003chr data-start=\"1891\" data-end=\"1894\"\u003e\n\u003ch2 data-section-id=\"zte05f\" data-start=\"1896\" data-end=\"1918\"\u003eWhat This Part Does\u003c\/h2\u003e\n\u003cp data-start=\"1920\" data-end=\"2022\"\u003eThe \u003cstrong data-start=\"1924\" data-end=\"1953\"\u003e36999MC igniter electrode\u003c\/strong\u003e performs two important functions in your RV furnace ignition system.\u003c\/p\u003e\n\u003cp data-start=\"2024\" data-end=\"2090\"\u003e\u003cstrong data-start=\"2024\" data-end=\"2037\"\u003eIgnition:\u003c\/strong\u003e Generates the spark that ignites the propane burner.\u003c\/p\u003e\n\u003cp data-start=\"2092\" data-end=\"2193\"\u003e\u003cstrong data-start=\"2092\" data-end=\"2110\"\u003eFlame sensing:\u003c\/strong\u003e Detects the burner flame and signals the control board that ignition has occurred.\u003c\/p\u003e\n\u003cp data-start=\"2195\" data-end=\"2296\"\u003eIf the electrode cannot properly detect the flame, the furnace will shut down as a safety precaution.\u003c\/p\u003e\n\u003chr data-start=\"2298\" data-end=\"2301\"\u003e\n\u003ch2 data-section-id=\"wpx3w7\" data-start=\"2303\" data-end=\"2353\"\u003eSigns Your Furnace Igniter May Need Replacement\u003c\/h2\u003e\n\u003cp data-start=\"2355\" data-end=\"2446\"\u003eYou may need to replace the igniter electrode if your furnace shows the following symptoms:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli data-start=\"2450\" data-end=\"2498\"\u003eFurnace blower runs but burner will not ignite\u003c\/li\u003e\n\u003cli data-start=\"2501\" data-end=\"2551\"\u003eFurnace attempts ignition but shuts down quickly\u003c\/li\u003e\n\u003cli data-start=\"2554\" data-end=\"2588\"\u003eRepeated clicking during startup\u003c\/li\u003e\n\u003cli data-start=\"2591\" data-end=\"2642\"\u003eFurnace locks out after several ignition attempts\u003c\/li\u003e\n\u003cli data-start=\"2645\" data-end=\"2702\"\u003eVisible cracks or heavy carbon buildup on the electrode\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"2704\" data-end=\"2775\"\u003eReplacing the igniter electrode often restores normal furnace ignition.\u003c\/p\u003e\n\u003chr data-start=\"2777\" data-end=\"2780\"\u003e\n\u003ch2 data-section-id=\"1r8frcv\" data-start=\"2782\" data-end=\"2811\"\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003cp data-start=\"2813\" data-end=\"3019\"\u003e\u003cstrong data-start=\"2813\" data-end=\"2861\"\u003eWhat does a dual-sense igniter electrode do?\u003c\/strong\u003e\u003cbr data-start=\"2861\" data-end=\"2864\"\u003eA dual-sense electrode both \u003cstrong data-start=\"2892\" data-end=\"2951\"\u003ecreates the ignition spark and detects the burner flame\u003c\/strong\u003e, allowing the furnace control board to confirm successful ignition.\u003c\/p\u003e\n\u003cp data-start=\"3021\" data-end=\"3206\"\u003e\u003cstrong data-start=\"3021\" data-end=\"3073\"\u003eWhat furnaces use the 36999MC igniter electrode?\u003c\/strong\u003e\u003cbr data-start=\"3073\" data-end=\"3076\"\u003eIt is used as a replacement for igniters in \u003cstrong data-start=\"3120\" data-end=\"3205\"\u003eAtwood Hydro Flame furnaces including the 8516, 8520, 8525, 8531, and 8535 series\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp data-start=\"3208\" data-end=\"3344\"\u003e\u003cstrong data-start=\"3208\" data-end=\"3255\"\u003eCan a dirty igniter cause furnace problems?\u003c\/strong\u003e\u003cbr data-start=\"3255\" data-end=\"3258\"\u003eYes. Carbon buildup or corrosion can prevent proper spark generation or flame sensing.\u003c\/p\u003e\n\u003chr data-start=\"3346\" data-end=\"3349\"\u003e\n\u003ch2 data-section-id=\"1n9sz8f\" data-start=\"3351\" data-end=\"3385\"\u003eWhy Buy From RVFurnaceGuys.com?\u003c\/h2\u003e\n\u003cp data-start=\"3387\" data-end=\"3633\"\u003eAt \u003cstrong data-start=\"3390\" data-end=\"3411\"\u003eRVFurnaceGuys.com\u003c\/strong\u003e, we specialize in \u003cstrong data-start=\"3430\" data-end=\"3477\"\u003eRV furnace parts and heating system repairs\u003c\/strong\u003e. Our goal is to help RV owners and technicians quickly diagnose furnace issues and find the correct replacement parts to get heating systems running again.\u003c\/p\u003e","brand":"RV Furnace Guys","offers":[{"title":"Default Title","offer_id":47879796523249,"sku":null,"price":27.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0784\/4941\/0289\/files\/369991.jpg?v=1772900977"},{"product_id":"m-c-enterprises-37358mc-furnace-motor-replacement-for-atwood-8525-iii-rv-furnaces","title":"M.C. Enterprises 37358MC Furnace Motor – Replacement for Atwood 8525-III RV Furnaces","description":"\u003ch1 data-section-id=\"p1igig\" data-start=\"262\" data-end=\"348\"\u003eM.C. Enterprises 37358MC Furnace Motor – Replacement for Atwood 8525-III RV Furnaces\u003c\/h1\u003e\n\u003cp data-start=\"350\" data-end=\"642\"\u003eRestore reliable airflow and furnace operation with the \u003cstrong data-start=\"406\" data-end=\"448\"\u003eM.C. Enterprises 37358MC Furnace Motor\u003c\/strong\u003e. This replacement blower motor is designed specifically for \u003cstrong data-start=\"509\" data-end=\"559\"\u003eAtwood Hydro Flame 8525-III series RV furnaces\u003c\/strong\u003e and includes the \u003cstrong data-start=\"577\" data-end=\"610\"\u003emounting bracket and fittings\u003c\/strong\u003e needed for proper installation.\u003c\/p\u003e\n\u003cp data-start=\"644\" data-end=\"929\"\u003eThe furnace motor powers the blower that circulates air through the heat exchanger and distributes warm air throughout your RV. If the motor fails or begins to wear out, the furnace may not start properly, may shut down during operation, or may fail to move warm air through the vents.\u003c\/p\u003e\n\u003cp data-start=\"931\" data-end=\"1050\"\u003eReplacing a worn motor with the \u003cstrong data-start=\"963\" data-end=\"988\"\u003e37358MC furnace motor\u003c\/strong\u003e can restore proper airflow and dependable RV furnace heating.\u003c\/p\u003e\n\u003chr data-start=\"1052\" data-end=\"1055\"\u003e\n\u003ch2 data-section-id=\"1ma7m6t\" data-start=\"1057\" data-end=\"1072\"\u003eKey Features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli data-start=\"1076\" data-end=\"1129\"\u003e\u003cstrong data-start=\"1076\" data-end=\"1129\"\u003eM.C. Enterprises replacement furnace blower motor\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli data-start=\"1132\" data-end=\"1192\"\u003eDesigned for \u003cstrong data-start=\"1145\" data-end=\"1192\"\u003eAtwood Hydro Flame 8525-III series furnaces\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1195\" data-end=\"1237\"\u003eIncludes \u003cstrong data-start=\"1204\" data-end=\"1237\"\u003emounting bracket and fittings\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1240\" data-end=\"1289\"\u003eHelps restore proper blower operation and airflow\u003c\/li\u003e\n\u003cli data-start=\"1292\" data-end=\"1340\"\u003eDurable construction for RV furnace environments\u003c\/li\u003e\n\u003cli data-start=\"1343\" data-end=\"1400\"\u003eDirect replacement motor for select Atwood furnace models\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1402\" data-end=\"1405\"\u003e\n\u003ch2 data-section-id=\"18dvupj\" data-start=\"1407\" data-end=\"1435\"\u003eCompatible Furnace Models\u003c\/h2\u003e\n\u003cp data-start=\"1437\" data-end=\"1531\"\u003eThe \u003cstrong data-start=\"1441\" data-end=\"1483\"\u003eM.C. Enterprises 37358MC Furnace Motor\u003c\/strong\u003e is compatible with the following furnace model:\u003c\/p\u003e\n\u003ch3 data-section-id=\"95juzb\" data-start=\"1533\" data-end=\"1548\"\u003e8525 Series\u003c\/h3\u003e\n\u003cul data-start=\"1549\" data-end=\"1563\"\u003e\n\u003cli data-section-id=\"id4346\" data-start=\"1549\" data-end=\"1563\"\u003e\n\u003cp data-start=\"1551\" data-end=\"1563\"\u003e\u003cstrong data-start=\"1551\" data-end=\"1563\"\u003e8525-III\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"1565\" data-end=\"1646\"\u003eAlways confirm your furnace model number before ordering to ensure compatibility.\u003c\/p\u003e\n\u003chr data-start=\"1648\" data-end=\"1651\"\u003e\n\u003ch2 data-section-id=\"zte05f\" data-start=\"1653\" data-end=\"1675\"\u003eWhat This Part Does\u003c\/h2\u003e\n\u003cp data-start=\"1677\" data-end=\"1802\"\u003eThe \u003cstrong data-start=\"1681\" data-end=\"1705\"\u003efurnace blower motor\u003c\/strong\u003e powers the fan that moves air through the furnace and distributes heated air throughout your RV.\u003c\/p\u003e\n\u003cp data-start=\"1804\" data-end=\"1850\"\u003eWhen the thermostat calls for heat, the motor:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli data-start=\"1855\" data-end=\"1895\"\u003eStarts the airflow through the furnace\u003c\/li\u003e\n\u003cli data-start=\"1899\" data-end=\"1935\"\u003eAllows the burner to ignite safely\u003c\/li\u003e\n\u003cli data-start=\"1939\" data-end=\"1987\"\u003eCirculates heated air through the RV duct system\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"1989\" data-end=\"2082\"\u003eIf the blower motor fails, the furnace may not start or may shut down as a safety precaution.\u003c\/p\u003e\n\u003chr data-start=\"2084\" data-end=\"2087\"\u003e\n\u003ch2 data-section-id=\"d7g7cm\" data-start=\"2089\" data-end=\"2137\"\u003eSigns Your Furnace Motor May Need Replacement\u003c\/h2\u003e\n\u003cp data-start=\"2139\" data-end=\"2207\"\u003eA failing furnace motor can cause several heating issues, including:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli data-start=\"2211\" data-end=\"2245\"\u003eRV furnace \u003cstrong data-start=\"2222\" data-end=\"2245\"\u003eblower not starting\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2248\" data-end=\"2290\"\u003eFurnace \u003cstrong data-start=\"2256\" data-end=\"2290\"\u003ehums but the fan does not spin\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2293\" data-end=\"2327\"\u003eFurnace \u003cstrong data-start=\"2301\" data-end=\"2327\"\u003estarts then shuts down\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2330\" data-end=\"2365\"\u003e\n\u003cstrong data-start=\"2330\" data-end=\"2354\"\u003eLittle or no airflow\u003c\/strong\u003e from vents\u003c\/li\u003e\n\u003cli data-start=\"2368\" data-end=\"2416\"\u003e\n\u003cstrong data-start=\"2368\" data-end=\"2399\"\u003eSquealing or grinding noise\u003c\/strong\u003e from the furnace\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"2418\" data-end=\"2501\"\u003eReplacing the blower motor can restore proper airflow and normal furnace operation.\u003c\/p\u003e\n\u003chr data-start=\"2503\" data-end=\"2506\"\u003e\n\u003ch2 data-section-id=\"1r8frcv\" data-start=\"2508\" data-end=\"2537\"\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003cp data-start=\"2539\" data-end=\"2711\"\u003e\u003cstrong data-start=\"2539\" data-end=\"2574\"\u003eWhat does the furnace motor do?\u003c\/strong\u003e\u003cbr data-start=\"2574\" data-end=\"2577\"\u003eThe blower motor powers the fan that moves air through the furnace heat exchanger and distributes warm air through the RV duct system.\u003c\/p\u003e\n\u003cp data-start=\"2713\" data-end=\"2881\"\u003e\u003cstrong data-start=\"2713\" data-end=\"2761\"\u003eWhat are symptoms of a bad RV furnace motor?\u003c\/strong\u003e\u003cbr data-start=\"2761\" data-end=\"2764\"\u003eCommon signs include \u003cstrong data-start=\"2785\" data-end=\"2880\"\u003ethe blower not starting, poor airflow, loud motor noise, or furnace shutdown during startup\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp data-start=\"2883\" data-end=\"3030\"\u003e\u003cstrong data-start=\"2883\" data-end=\"2933\"\u003eDoes this motor include installation hardware?\u003c\/strong\u003e\u003cbr data-start=\"2933\" data-end=\"2936\"\u003eYes. The \u003cstrong data-start=\"2945\" data-end=\"3005\"\u003e37358MC motor includes the mounting bracket and fittings\u003c\/strong\u003e needed for installation.\u003c\/p\u003e\n\u003chr data-start=\"3032\" data-end=\"3035\"\u003e\n\u003ch2 data-section-id=\"1n9sz8f\" data-start=\"3037\" data-end=\"3071\"\u003eWhy Buy From RVFurnaceGuys.com?\u003c\/h2\u003e\n\u003cp data-start=\"3073\" data-end=\"3333\"\u003eAt \u003cstrong data-start=\"3076\" data-end=\"3097\"\u003eRVFurnaceGuys.com\u003c\/strong\u003e, we specialize exclusively in \u003cstrong data-start=\"3128\" data-end=\"3175\"\u003eRV furnace parts and heating system repairs\u003c\/strong\u003e. Our goal is to help RV owners and technicians quickly diagnose furnace problems and find the correct replacement parts to get heating systems running again.\u003c\/p\u003e","brand":"RV Furnace Guys","offers":[{"title":"Default Title","offer_id":47879805763825,"sku":null,"price":159.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0784\/4941\/0289\/files\/37358MC.jpg?v=1772902382"},{"product_id":"dometic™-atwood-33782-hydro-flame-furnace-circuit-breaker-15-amp","title":"Dometic™ Atwood 33782 Hydro Flame Furnace Circuit Breaker – 15 AMP","description":"\u003ch1 data-section-id=\"1g9c2y9\" data-start=\"0\" data-end=\"68\"\u003eDometic™ Atwood 33782 Hydro Flame Furnace Circuit Breaker – 15 AMP\u003c\/h1\u003e\n\u003ch2 data-section-id=\"kndxbv\" data-start=\"70\" data-end=\"126\"\u003eDometic Atwood 33782 Furnace Circuit Breaker – 15 AMP\u003c\/h2\u003e\n\u003cp data-start=\"128\" data-end=\"462\"\u003eThe \u003cstrong data-start=\"132\" data-end=\"193\"\u003eDometic™ Atwood 33782 Hydro Flame Furnace Circuit Breaker\u003c\/strong\u003e is a \u003cstrong data-start=\"199\" data-end=\"231\"\u003e15-amp push-to-reset breaker\u003c\/strong\u003e designed to protect the electrical system of many \u003cstrong data-start=\"282\" data-end=\"316\"\u003eAtwood Hydro Flame RV furnaces\u003c\/strong\u003e. This breaker interrupts power when the circuit becomes overloaded or experiences a short, helping prevent damage to critical furnace components.\u003c\/p\u003e\n\u003cp data-start=\"464\" data-end=\"642\"\u003eIf your RV furnace \u003cstrong data-start=\"483\" data-end=\"569\"\u003eloses power, shuts down unexpectedly, or will not run even though power is present\u003c\/strong\u003e, the circuit breaker may have tripped or failed and require replacement.\u003c\/p\u003e\n\u003cp data-start=\"644\" data-end=\"802\"\u003eThe \u003cstrong data-start=\"648\" data-end=\"673\"\u003e33782 circuit breaker\u003c\/strong\u003e is used in several Atwood furnace models and provides reliable electrical protection to help keep your furnace operating safely.\u003c\/p\u003e\n\u003chr data-start=\"804\" data-end=\"807\"\u003e\n\u003ch2 data-section-id=\"1d7mrtu\" data-start=\"809\" data-end=\"820\"\u003eFeatures\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli data-start=\"824\" data-end=\"871\"\u003eGenuine \u003cstrong data-start=\"832\" data-end=\"869\"\u003eDometic \/ Atwood replacement part\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"874\" data-end=\"916\"\u003e\u003cstrong data-start=\"874\" data-end=\"914\"\u003e15 AMP push-to-reset circuit breaker\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli data-start=\"919\" data-end=\"973\"\u003eProtects furnace electrical components from overload\u003c\/li\u003e\n\u003cli data-start=\"976\" data-end=\"1025\"\u003eDesigned for \u003cstrong data-start=\"989\" data-end=\"1023\"\u003eAtwood Hydro Flame RV furnaces\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1028\" data-end=\"1066\"\u003eCompact design for easy installation\u003c\/li\u003e\n\u003cli data-start=\"1069\" data-end=\"1109\"\u003eReliable resettable breaker protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1111\" data-end=\"1114\"\u003e\n\u003ch2 data-section-id=\"18dvupj\" data-start=\"1116\" data-end=\"1144\"\u003eCompatible Furnace Models\u003c\/h2\u003e\n\u003cp data-start=\"1146\" data-end=\"1233\"\u003eThis circuit breaker is used in the following \u003cstrong data-start=\"1192\" data-end=\"1232\"\u003eAtwood Hydro Flame RV furnace models\u003c\/strong\u003e:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli data-start=\"1237\" data-end=\"1251\"\u003e\u003cstrong data-start=\"1237\" data-end=\"1249\"\u003e8535-III\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli data-start=\"1254\" data-end=\"1267\"\u003e\u003cstrong data-start=\"1254\" data-end=\"1265\"\u003e8535-IV\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli data-start=\"1270\" data-end=\"1285\"\u003e\u003cstrong data-start=\"1270\" data-end=\"1283\"\u003e8935-DC-I\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli data-start=\"1288\" data-end=\"1303\"\u003e\u003cstrong data-start=\"1288\" data-end=\"1301\"\u003e8940-DC-I\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli data-start=\"1306\" data-end=\"1322\"\u003e\u003cstrong data-start=\"1306\" data-end=\"1320\"\u003e8935-DC-II\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli data-start=\"1325\" data-end=\"1341\"\u003e\u003cstrong data-start=\"1325\" data-end=\"1339\"\u003e8940-DC-II\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli data-start=\"1344\" data-end=\"1373\"\u003e\u003cstrong data-start=\"1344\" data-end=\"1371\"\u003e8935-DC-III (with door)\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli data-start=\"1376\" data-end=\"1405\"\u003e\u003cstrong data-start=\"1376\" data-end=\"1403\"\u003e8940-DC-III (with door)\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"1407\" data-end=\"1456\"\u003eAlways verify your furnace model before ordering.\u003c\/p\u003e\n\u003chr data-start=\"1458\" data-end=\"1461\"\u003e\n\u003ch2 data-section-id=\"3ipjz4\" data-start=\"1463\" data-end=\"1488\"\u003eProduct Specifications\u003c\/h2\u003e\n\u003cdiv class=\"TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"1490\" data-end=\"1729\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"1490\" data-end=\"1517\"\u003e\n\u003ctr data-start=\"1490\" data-end=\"1517\"\u003e\n\u003cth data-start=\"1490\" data-end=\"1506\" data-col-size=\"sm\" class=\"\"\u003eSpecification\u003c\/th\u003e\n\u003cth data-start=\"1506\" data-end=\"1517\" data-col-size=\"sm\" class=\"\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"1528\" data-end=\"1729\"\u003e\n\u003ctr data-start=\"1528\" data-end=\"1551\"\u003e\n\u003ctd data-start=\"1528\" data-end=\"1542\" data-col-size=\"sm\"\u003ePart Number\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"1542\" data-end=\"1551\"\u003e33782\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1552\" data-end=\"1587\"\u003e\n\u003ctd data-start=\"1552\" data-end=\"1567\" data-col-size=\"sm\"\u003eManufacturer\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"1567\" data-end=\"1587\"\u003eDometic \/ Atwood\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1588\" data-end=\"1627\"\u003e\n\u003ctd data-start=\"1588\" data-end=\"1600\" data-col-size=\"sm\"\u003ePart Type\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"1600\" data-end=\"1627\"\u003eFurnace Circuit Breaker\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1628\" data-end=\"1649\"\u003e\n\u003ctd data-start=\"1628\" data-end=\"1639\" data-col-size=\"sm\"\u003eAmperage\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"1639\" data-end=\"1649\"\u003e15 AMP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1650\" data-end=\"1680\"\u003e\n\u003ctd data-start=\"1650\" data-end=\"1663\" data-col-size=\"sm\"\u003eReset Type\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"1663\" data-end=\"1680\"\u003ePush-to-Reset\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1681\" data-end=\"1729\"\u003e\n\u003ctd data-start=\"1681\" data-end=\"1695\" data-col-size=\"sm\"\u003eApplication\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"1695\" data-end=\"1729\"\u003eAtwood Hydro Flame RV Furnaces\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003chr data-start=\"1731\" data-end=\"1734\"\u003e\n\u003ch2 data-section-id=\"3cgp6a\" data-start=\"1736\" data-end=\"1790\"\u003eCommon Symptoms of a Faulty Furnace Circuit Breaker\u003c\/h2\u003e\n\u003cp data-start=\"1792\" data-end=\"1850\"\u003eYou may need to replace the circuit breaker if you notice:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli data-start=\"1854\" data-end=\"1881\"\u003eFurnace will not power on\u003c\/li\u003e\n\u003cli data-start=\"1884\" data-end=\"1916\"\u003eFurnace repeatedly loses power\u003c\/li\u003e\n\u003cli data-start=\"1919\" data-end=\"1943\"\u003eBreaker will not reset\u003c\/li\u003e\n\u003cli data-start=\"1946\" data-end=\"1989\"\u003eFurnace shuts down when the blower starts\u003c\/li\u003e\n\u003cli data-start=\"1992\" data-end=\"2035\"\u003eIntermittent furnace electrical operation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"2037\" data-end=\"2172\"\u003eCircuit breakers can weaken over time due to \u003cstrong data-start=\"2082\" data-end=\"2171\"\u003erepeated electrical loads, vibration, or heat exposure inside the furnace compartment\u003c\/strong\u003e.\u003c\/p\u003e\n\u003chr data-start=\"2174\" data-end=\"2177\"\u003e\n\u003ch2 data-section-id=\"1hryhf7\" data-start=\"2179\" data-end=\"2185\"\u003eFAQ\u003c\/h2\u003e\n\u003ch3 data-section-id=\"ygc4q7\" data-start=\"2187\" data-end=\"2232\"\u003eWhat does the furnace circuit breaker do?\u003c\/h3\u003e\n\u003cp data-start=\"2233\" data-end=\"2382\"\u003eThe circuit breaker protects the furnace by \u003cstrong data-start=\"2277\" data-end=\"2348\"\u003eshutting off electrical power if the circuit draws too much current\u003c\/strong\u003e, preventing damage to components.\u003c\/p\u003e\n\u003ch3 data-section-id=\"17k4a8o\" data-start=\"2384\" data-end=\"2419\"\u003eWhat does “push-to-reset” mean?\u003c\/h3\u003e\n\u003cp data-start=\"2420\" data-end=\"2548\"\u003eIf the breaker trips, you can \u003cstrong data-start=\"2450\" data-end=\"2493\"\u003epress the reset button to restore power\u003c\/strong\u003e once the issue causing the overload has been resolved.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1a3nofa\" data-start=\"2550\" data-end=\"2599\"\u003eWhy would my RV furnace circuit breaker trip?\u003c\/h3\u003e\n\u003cp data-start=\"2600\" data-end=\"2707\"\u003eCommon causes include \u003cstrong data-start=\"2622\" data-end=\"2706\"\u003eblower motor issues, wiring faults, or electrical overload in the furnace system\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3 data-section-id=\"98dagl\" data-start=\"2709\" data-end=\"2755\"\u003eCan a weak breaker cause furnace problems?\u003c\/h3\u003e\n\u003cp data-start=\"2756\" data-end=\"2854\"\u003eYes. A failing breaker can cause \u003cstrong data-start=\"2789\" data-end=\"2853\"\u003eintermittent power loss or prevent the furnace from starting\u003c\/strong\u003e.\u003c\/p\u003e","brand":"RV Furnace Guys","offers":[{"title":"Default Title","offer_id":47892534034673,"sku":null,"price":37.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0784\/4941\/0289\/files\/337821.jpg?v=1773263845"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0784\/4941\/0289\/collections\/8500_III_Main_Parts_Image.png?v=1774209882","url":"https:\/\/rvfurnaceguys.com\/collections\/8500-iii-hydroflame-parts.oembed","provider":"RV Furnace Guys","version":"1.0","type":"link"}