{"title":"Gas Valves and Burner Components - Dometic","description":"\u003ch3 data-start=\"2317\" data-end=\"2330\"\u003eThis Category Includes:\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli data-start=\"2333\" data-end=\"2344\"\u003eGas Valve\u003c\/li\u003e\n\u003cli data-start=\"2347\" data-end=\"2368\"\u003eGas Solenoid Valves\u003c\/li\u003e\n\u003cli data-start=\"2371\" data-end=\"2379\"\u003eBurner\u003c\/li\u003e\n\u003cli data-start=\"2382\" data-end=\"2392\"\u003eManifold\u003c\/li\u003e\n\u003cli data-start=\"2395\" data-end=\"2411\"\u003eGas Inlet Pipe\u003c\/li\u003e\n\u003cli data-start=\"2414\" data-end=\"2431\"\u003ePilot Regulator\u003c\/li\u003e\n\u003cli data-start=\"2414\" data-end=\"2431\"\u003eConversion Kit\u003c\/li\u003e\n\u003c\/ul\u003e","products":[{"product_id":"dometic-atwood-rv-furnace-gas-valve-part-31098","title":"Dometic \/ Atwood RV Furnace Gas Valve – Part #31098","description":"\u003cp data-end=\"440\" data-start=\"55\"\u003eReplace your old or failing propane gas valve with this OEM-style Dometic\/Atwood furnace gas valve, Part #31098. This precision-engineered gas valve is designed to safely control the flow of LP gas to the burner in compatible Dometic and Atwood RV furnaces. Built to meet factory specifications, it helps restore reliable ignition, steady flame performance, and consistent heat output.\u003c\/p\u003e\n\u003cp data-end=\"675\" data-start=\"442\"\u003eIf your furnace struggles to ignite, shuts off unexpectedly, or produces inconsistent heat, a faulty gas valve may be the cause. Replacing it with the correct OEM replacement can restore dependable operation and safe LP gas delivery.\u003c\/p\u003e\n\u003ch2 data-end=\"690\" data-start=\"677\"\u003eKey Features:\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli data-end=\"735\" data-start=\"694\"\u003eOEM Replacement Gas Valve – Part #31098\u003c\/li\u003e\n\u003cli data-end=\"788\" data-start=\"738\"\u003eDesigned for Dometic \/ Atwood LP gas RV furnaces\u003c\/li\u003e\n\u003cli data-end=\"833\" data-start=\"791\"\u003eControls propane flow to burner assembly\u003c\/li\u003e\n\u003cli data-end=\"880\" data-start=\"836\"\u003eDurable construction for long service life\u003c\/li\u003e\n\u003cli data-end=\"924\" data-start=\"883\"\u003eDirect-fit design for compatible models\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-end=\"965\" data-start=\"926\"\u003eCommon Symptoms of a Failing Gas Valve:\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli data-end=\"994\" data-start=\"969\"\u003eFurnace will not ignite\u003c\/li\u003e\n\u003cli data-end=\"1035\" data-start=\"997\"\u003eBurner lights briefly then shuts off\u003c\/li\u003e\n\u003cli data-end=\"1060\" data-start=\"1038\"\u003eWeak or uneven flame\u003c\/li\u003e\n\u003cli data-end=\"1095\" data-start=\"1063\"\u003eFurnace goes into lockout mode\u003c\/li\u003e\n\u003cli data-end=\"1150\" data-start=\"1098\"\u003eThermostat calling for heat but no burner activity\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-end=\"1255\" data-start=\"1152\"\u003eReplacing a worn or malfunctioning gas valve can resolve many common ignition and fuel delivery issues.\u003c\/p\u003e\n\u003ch2 data-end=\"1297\" data-start=\"1257\"\u003eCompatibility – Works With These Models:\u003c\/h2\u003e\n\u003cp data-end=\"1515\" data-start=\"1299\"\u003e\u003cspan style=\"text-decoration: underline;\"\u003eAFSAD \/ AFSD Series:\u003c\/span\u003e\u003cbr\u003eAFSAD12111\u003cbr data-end=\"1333\" data-start=\"1330\"\u003eAFSD12111\u003cbr data-end=\"1345\" data-start=\"1342\"\u003eAFSAD12121\u003cbr data-end=\"1358\" data-start=\"1355\"\u003eAFSD12121\u003cbr data-end=\"1370\" data-start=\"1367\"\u003eAFSAD12131\u003cbr data-end=\"1383\" data-start=\"1380\"\u003eAFSD12131\u003cbr data-end=\"1395\" data-start=\"1392\"\u003eAFSAD12141\u003cbr data-end=\"1408\" data-start=\"1405\"\u003eAFSD12141\u003cbr data-end=\"1420\" data-start=\"1417\"\u003eAFSD16111\u003cbr data-end=\"1432\" data-start=\"1429\"\u003eAFSD16121\u003cbr data-end=\"1444\" data-start=\"1441\"\u003eAFSD16131\u003cbr data-end=\"1456\" data-start=\"1453\"\u003eAFSD16141\u003cbr data-end=\"1468\" data-start=\"1465\"\u003eAFSD20111\u003cbr data-end=\"1480\" data-start=\"1477\"\u003eAFSD20121\u003cbr data-end=\"1492\" data-start=\"1489\"\u003eAFSD20131\u003cbr data-end=\"1504\" data-start=\"1501\"\u003eAFSD20141\u003c\/p\u003e\n\u003cp data-end=\"1829\" data-start=\"1517\"\u003e\u003cspan style=\"text-decoration: underline;\"\u003eAFMD Series:\u003c\/span\u003e\u003cbr\u003eAFMD16111\u003cbr data-end=\"1542\" data-start=\"1539\"\u003eAFMD16121\u003cbr data-end=\"1554\" data-start=\"1551\"\u003eAFMD16131\u003cbr data-end=\"1566\" data-start=\"1563\"\u003eAFMD16141\u003cbr data-end=\"1578\" data-start=\"1575\"\u003eAFMD16151\u003cbr data-end=\"1590\" data-start=\"1587\"\u003eAFMD20111\u003cbr data-end=\"1602\" data-start=\"1599\"\u003eAFMD20121\u003cbr data-end=\"1614\" data-start=\"1611\"\u003eAFMD20131\u003cbr data-end=\"1626\" data-start=\"1623\"\u003eAFMD20141\u003cbr data-end=\"1638\" data-start=\"1635\"\u003eAFMD20151\u003cbr data-end=\"1650\" data-start=\"1647\"\u003eAFMD25111\u003cbr data-end=\"1662\" data-start=\"1659\"\u003eAFMD25121\u003cbr data-end=\"1674\" data-start=\"1671\"\u003eAFMD25131\u003cbr data-end=\"1686\" data-start=\"1683\"\u003eAFMD25141\u003cbr data-end=\"1698\" data-start=\"1695\"\u003eAFMD25151\u003cbr data-end=\"1710\" data-start=\"1707\"\u003eAFMD30111\u003cbr data-end=\"1722\" data-start=\"1719\"\u003eAFMD30121\u003cbr data-end=\"1734\" data-start=\"1731\"\u003eAFMD30131\u003cbr data-end=\"1746\" data-start=\"1743\"\u003eAFMD30141\u003cbr data-end=\"1758\" data-start=\"1755\"\u003eAFMD30151\u003cbr data-end=\"1770\" data-start=\"1767\"\u003eAFMD35111\u003cbr data-end=\"1782\" data-start=\"1779\"\u003eAFMD35121\u003cbr data-end=\"1794\" data-start=\"1791\"\u003eAFMD35131\u003cbr data-end=\"1806\" data-start=\"1803\"\u003eAFMD35141\u003cbr data-end=\"1818\" data-start=\"1815\"\u003eAFMD35151\u003c\/p\u003e\n\u003cp data-end=\"2018\" data-start=\"1831\"\u003e\u003cspan style=\"text-decoration: underline;\"\u003eDFMD \/ DFLD \/ DFMDH \/ DFSDH Series:\u003c\/span\u003e\u003cbr\u003eDFMD16111\u003cbr data-end=\"1879\" data-start=\"1876\"\u003eDFMD16121\u003cbr data-end=\"1891\" data-start=\"1888\"\u003eDFMDH25111\u003cbr data-end=\"1904\" data-start=\"1901\"\u003eDFMDH25121\u003cbr data-end=\"1917\" data-start=\"1914\"\u003eDFMDH30111\u003cbr data-end=\"1930\" data-start=\"1927\"\u003eDFMDH30121\u003cbr data-end=\"1943\" data-start=\"1940\"\u003eDFMDH35111\u003cbr data-end=\"1956\" data-start=\"1953\"\u003eDFMDH35121\u003cbr data-end=\"1969\" data-start=\"1966\"\u003eDFLD40111\u003cbr data-end=\"1981\" data-start=\"1978\"\u003eDFLD40121\u003cbr data-end=\"1993\" data-start=\"1990\"\u003eDFSDH20111\u003cbr data-end=\"2006\" data-start=\"2003\"\u003eDFSDH20121\u003c\/p\u003e\n\u003cp data-end=\"2099\" data-start=\"2020\"\u003eAlways verify your exact furnace model before ordering to ensure compatibility.\u003c\/p\u003e\n\u003ch2 data-end=\"2117\" data-start=\"2101\"\u003eWhat’s Included:\u003c\/h2\u003e\n\u003cul data-end=\"2153\" data-start=\"2119\"\u003e\n\u003cli data-end=\"2153\" data-start=\"2119\"\u003e\n\u003cp data-end=\"2153\" data-start=\"2121\"\u003e(1) LP Gas Valve – Part #31098\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-end=\"2174\" data-start=\"2155\"\u003eInstallation Notes:\u003c\/h2\u003e\n\u003cp data-end=\"2329\" data-start=\"2176\"\u003eTurn off propane supply and disconnect 12V power before servicing your furnace. Professional installation is recommended to ensure safe and proper setup.\u003c\/p\u003e\n\u003ch2\u003eFrequently Asked Questions:\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong data-end=\"95\" data-start=\"37\"\u003e1.  What does the Dometic \/ Atwood Gas Valve #31098 do?\u003c\/strong\u003e\u003cbr data-end=\"98\" data-start=\"95\"\u003eThe gas valve regulates the flow of LP propane gas from your RV’s supply line to the furnace burner. It opens during ignition and closes when the heating cycle ends, ensuring safe and controlled combustion.\u003c\/p\u003e\n\u003cp data-end=\"411\" data-start=\"306\"\u003e\u003cstrong data-end=\"364\" data-start=\"306\"\u003e2. How do I know if my gas valve needs to be replaced?\u003c\/strong\u003e\u003cbr data-end=\"367\" data-start=\"364\"\u003eCommon signs of a failing gas valve include:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli data-end=\"439\" data-start=\"414\"\u003eFurnace will not ignite\u003c\/li\u003e\n\u003cli data-end=\"480\" data-start=\"442\"\u003eBurner lights briefly then shuts off\u003c\/li\u003e\n\u003cli data-end=\"511\" data-start=\"483\"\u003eIntermittent or weak flame\u003c\/li\u003e\n\u003cli data-end=\"550\" data-start=\"514\"\u003eFurnace goes into ignition lockout\u003c\/li\u003e\n\u003cli data-end=\"590\" data-start=\"553\"\u003eBlower runs but no heat is produced\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-end=\"695\" data-start=\"592\"\u003eIf other components (like the sail switch or ignition board) test good, the gas valve may be the issue.\u003c\/p\u003e\n\u003cp data-end=\"899\" data-start=\"697\"\u003e\u003cstrong data-end=\"740\" data-start=\"697\"\u003e3. Is Part #31098 a direct replacement?\u003c\/strong\u003e\u003cbr data-end=\"743\" data-start=\"740\"\u003eYes. This is an OEM-style replacement designed to directly replace the original gas valve used on compatible Dometic and Atwood furnace models listed above.\u003c\/p\u003e\n\u003cp data-end=\"1115\" data-start=\"901\"\u003e\u003cstrong data-end=\"977\" data-start=\"901\"\u003e4. Does this valve work with both single-stage and multi-stage furnaces?\u003c\/strong\u003e\u003cbr data-end=\"980\" data-start=\"977\"\u003eThis valve is designed for compatible single-stage Dometic\/Atwood furnaces. Always verify your specific model to confirm compatibility.\u003c\/p\u003e\n\u003cp data-end=\"1385\" data-start=\"1117\"\u003e\u003cstrong data-end=\"1160\" data-start=\"1117\"\u003e5. Can I install this gas valve myself?\u003c\/strong\u003e\u003cbr data-end=\"1163\" data-start=\"1160\"\u003eInstallation requires disconnecting propane and 12V power and working with gas fittings. While experienced RV owners can perform the repair, professional installation is recommended to ensure safe propane system operation.\u003c\/p\u003e\n\u003cp data-end=\"1613\" data-start=\"1387\"\u003e\u003cstrong data-end=\"1442\" data-start=\"1387\"\u003e6. Do I need any additional parts for installation?\u003c\/strong\u003e\u003cbr data-end=\"1445\" data-start=\"1442\"\u003eIn most cases, the valve is a direct replacement. However, inspect existing fittings and gas lines for wear and replace seals or fittings if needed during installation.\u003c\/p\u003e\n\u003cp data-end=\"1881\" data-start=\"1615\"\u003e\u003cstrong data-end=\"1654\" data-start=\"1615\"\u003e7. Will this fix ignition problems?\u003c\/strong\u003e\u003cbr data-end=\"1657\" data-start=\"1654\"\u003eIf the problem is related to improper gas flow, sticking valves, or weak flame, replacing the gas valve often resolves ignition issues. However, ignition boards, sail switches, and electrodes can also cause similar symptoms.\u003c\/p\u003e\n\u003cp data-end=\"2138\" data-start=\"1883\"\u003e\u003cstrong data-end=\"1929\" data-start=\"1883\"\u003e8. How can I confirm this fits my furnace?\u003c\/strong\u003e\u003cbr data-end=\"1932\" data-start=\"1929\"\u003eCheck your furnace model number on the data plate inside the exterior access panel. Compare it with the compatibility list above before ordering. If unsure, reference your furnace manual or parts breakdown.\u003c\/p\u003e","brand":"RV Furnace Guys","offers":[{"title":"Default Title","offer_id":47826179653873,"sku":null,"price":97.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0784\/4941\/0289\/files\/31098GasValve1.webp?v=1771968740"},{"product_id":"dometic-atwood-rv-furnace-burner-head-part-30268","title":"Dometic \/ Atwood RV Furnace Burner Head – Part #30268 (Superseded Part #36043)","description":"\u003cp data-start=\"57\" data-end=\"434\"\u003eReplace a worn or corroded burner with the Dometic \/ Atwood Burner Head, Part #30268. This OEM-style replacement burner head is designed to deliver proper propane distribution and clean combustion inside compatible RV furnace models. If your furnace is experiencing delayed ignition, uneven flame, soot buildup, or weak heat output, a deteriorated burner head may be the cause.\u003c\/p\u003e\n\u003cp data-start=\"436\" data-end=\"579\"\u003eBuilt to meet original equipment specifications, Part #30268 ensures proper gas flow and flame pattern for safe, efficient heating performance.\u003c\/p\u003e\n\u003cp data-start=\"436\" data-end=\"579\"\u003eSuperseded Part #36043\u003c\/p\u003e\n\u003chr data-start=\"581\" data-end=\"584\"\u003e\n\u003ch2 data-start=\"586\" data-end=\"601\"\u003eKey Features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli data-start=\"605\" data-end=\"648\"\u003eOEM Replacement Burner Head – Part #30268\u003c\/li\u003e\n\u003cli data-start=\"651\" data-end=\"702\"\u003eDesigned for Dometic \/ Atwood propane RV furnaces\u003c\/li\u003e\n\u003cli data-start=\"705\" data-end=\"760\"\u003eEnsures proper LP gas distribution to burner assembly\u003c\/li\u003e\n\u003cli data-start=\"763\" data-end=\"802\"\u003ePromotes clean, stable flame ignition\u003c\/li\u003e\n\u003cli data-start=\"805\" data-end=\"849\"\u003eDurable construction for long service life\u003c\/li\u003e\n\u003cli data-start=\"852\" data-end=\"898\"\u003eDirect-fit replacement for compatible models\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"900\" data-end=\"903\"\u003e\n\u003ch2 data-start=\"905\" data-end=\"948\"\u003eCommon Symptoms of a Failing Burner Head\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli data-start=\"952\" data-end=\"996\"\u003eDelayed ignition or small flame at startup\u003c\/li\u003e\n\u003cli data-start=\"999\" data-end=\"1032\"\u003eUneven or unstable burner flame\u003c\/li\u003e\n\u003cli data-start=\"1035\" data-end=\"1071\"\u003eSoot buildup in combustion chamber\u003c\/li\u003e\n\u003cli data-start=\"1074\" data-end=\"1100\"\u003ePoor heating performance\u003c\/li\u003e\n\u003cli data-start=\"1103\" data-end=\"1129\"\u003eExcessive ignition noise\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"1131\" data-end=\"1313\"\u003eA damaged or partially clogged burner can disrupt combustion efficiency and cause ignition issues. Replacing the burner head restores proper flame characteristics and heating output.\u003c\/p\u003e\n\u003chr data-start=\"1315\" data-end=\"1318\"\u003e\n\u003ch1 data-start=\"1320\" data-end=\"1339\"\u003eCompatible Models\u003c\/h1\u003e\n\u003cp data-start=\"1341\" data-end=\"1409\"\u003eThis burner head fits the following Dometic \/ Atwood furnace series:\u003c\/p\u003e\n\u003chr data-start=\"1411\" data-end=\"1414\"\u003e\n\u003ch3 data-start=\"1416\" data-end=\"1436\"\u003e79XX-II Series\u003c\/h3\u003e\n\u003ch3 data-start=\"1468\" data-end=\"1488\"\u003e80XX-II Series\u003c\/h3\u003e\n\u003chr data-start=\"1500\" data-end=\"1503\"\u003e\n\u003ch3 data-start=\"1505\" data-end=\"1525\"\u003e85XX-IV Series\u003c\/h3\u003e\n\u003chr data-start=\"1577\" data-end=\"1580\"\u003e\n\u003ch3 data-start=\"1582\" data-end=\"1600\"\u003eAFSAD Series\u003c\/h3\u003e\n\u003chr data-start=\"1654\" data-end=\"1657\"\u003e\n\u003ch3 data-start=\"1659\" data-end=\"1676\"\u003eAFSD Series\u003c\/h3\u003e\n\u003chr data-start=\"1822\" data-end=\"1825\"\u003e\n\u003ch3 data-start=\"1827\" data-end=\"1844\"\u003eAFMD Series\u003c\/h3\u003e\n\u003chr data-start=\"2146\" data-end=\"2149\"\u003e\n\u003ch3 data-start=\"2151\" data-end=\"2169\"\u003eDFSD Series\u003c\/h3\u003e\n\u003chr data-start=\"2249\" data-end=\"2252\"\u003e\n\u003ch3 data-start=\"2254\" data-end=\"2272\"\u003eDFMD Series\u003c\/h3\u003e\n\u003chr data-start=\"2300\" data-end=\"2303\"\u003e\n\u003cp data-start=\"2305\" data-end=\"2385\"\u003eAlways confirm your exact furnace model before ordering to ensure compatibility.\u003c\/p\u003e\n\u003chr data-start=\"2387\" data-end=\"2390\"\u003e\n\u003ch2 data-start=\"2392\" data-end=\"2410\"\u003eWhat’s Included\u003c\/h2\u003e\n\u003cul data-start=\"2412\" data-end=\"2445\"\u003e\n\u003cli data-start=\"2412\" data-end=\"2445\"\u003e\n\u003cp data-start=\"2414\" data-end=\"2445\"\u003e(1) Burner Head – Part #30268\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"2447\" data-end=\"2507\"\u003eMounting hardware and additional components sold separately.\u003c\/p\u003e\n\u003chr data-start=\"2509\" data-end=\"2512\"\u003e\n\u003ch2 data-start=\"2514\" data-end=\"2535\"\u003eInstallation Notes\u003c\/h2\u003e\n\u003cp data-start=\"2537\" data-end=\"2748\"\u003eDisconnect propane supply and 12V power before servicing your furnace. Inspect gas orifices and burner tube during replacement. Professional installation is recommended if you are unfamiliar with LP gas systems.\u003c\/p\u003e\n\u003chr data-start=\"2750\" data-end=\"2753\"\u003e\n\u003ch2 data-start=\"2755\" data-end=\"2784\"\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003cp data-start=\"2786\" data-end=\"2930\"\u003eWhat does the burner head do?\u003cbr data-start=\"2815\" data-end=\"2818\"\u003eThe burner head distributes propane evenly for proper combustion and consistent flame across the heat exchanger.\u003c\/p\u003e\n\u003cp data-start=\"2932\" data-end=\"3109\"\u003eWill this fix ignition issues?\u003cbr data-start=\"2962\" data-end=\"2965\"\u003eIf ignition is delayed, uneven, or producing soot due to a degraded burner surface, replacing the burner head often restores proper performance.\u003c\/p\u003e\n\u003cp data-start=\"3111\" data-end=\"3246\"\u003eDoes this include the gas valve or orifice?\u003cbr data-start=\"3154\" data-end=\"3157\"\u003eNo — this listing is for the burner head only. Additional components are sold separately.\u003c\/p\u003e","brand":"RV Furnace Guys","offers":[{"title":"Default Title","offer_id":47828917780721,"sku":null,"price":36.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0784\/4941\/0289\/files\/30268burnerhead.png?v=1772065809"},{"product_id":"dometic-atwood-30209-furnace-burner-burner-head-lp-natural-gas-8900-and-afla-afld-series","title":"Dometic \/ Atwood 30209 Furnace Burner – Burner Head (LP \u0026 Natural Gas) - 8900, and AFLA\/AFLD Series","description":"\u003ch2 data-start=\"133\" data-end=\"208\"\u003eDometic \/ Atwood 30209 Furnace Burner – Burner Head (LP \u0026amp; Natural Gas)\u003c\/h2\u003e\n\u003cp data-start=\"209\" data-end=\"236\"\u003e\u003cstrong data-start=\"209\" data-end=\"236\"\u003eGenuine OEM Replacement\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"238\" data-end=\"399\"\u003e\u003cstrong data-start=\"238\" data-end=\"254\"\u003ePart Number:\u003c\/strong\u003e 30209\u003cbr data-start=\"260\" data-end=\"263\"\u003e\u003cstrong data-start=\"263\" data-end=\"280\"\u003eProduct Type:\u003c\/strong\u003e Furnace Burner Head\u003cbr data-start=\"300\" data-end=\"303\"\u003e\u003cstrong data-start=\"303\" data-end=\"317\"\u003eFuel Type:\u003c\/strong\u003e LP Gas \u0026amp; Natural Gas\u003cbr data-start=\"338\" data-end=\"341\"\u003e\u003cstrong data-start=\"341\" data-end=\"357\"\u003eApplication:\u003c\/strong\u003e Atwood 8900 Series \u0026amp; AFLA\/AFLD Furnaces\u003c\/p\u003e\n\u003chr data-start=\"401\" data-end=\"404\"\u003e\n\u003ch3 data-start=\"406\" data-end=\"426\"\u003eProduct Overview\u003c\/h3\u003e\n\u003cp data-start=\"428\" data-end=\"700\"\u003eThe \u003cstrong data-start=\"432\" data-end=\"478\"\u003eDometic \/ Atwood 30209 Furnace Burner Head\u003c\/strong\u003e is a genuine OEM replacement component designed for select \u003cstrong data-start=\"538\" data-end=\"576\"\u003eAtwood LP and Natural Gas furnaces\u003c\/strong\u003e. This burner head is responsible for properly distributing fuel and producing a stable flame within the combustion chamber.\u003c\/p\u003e\n\u003cp data-start=\"702\" data-end=\"967\"\u003eManufactured to original factory specifications, Part 30209 ensures proper fuel combustion, reliable ignition, and safe furnace operation. Replacing a worn, corroded, or clogged burner head helps restore consistent flame characteristics and prevent ignition issues.\u003c\/p\u003e\n\u003cp data-start=\"969\" data-end=\"1105\"\u003eBuilt to withstand high heat and continuous use, this OEM burner head is engineered for long-term durability in RV heating applications.\u003c\/p\u003e\n\u003chr data-start=\"1107\" data-end=\"1110\"\u003e\n\u003ch3 data-start=\"1112\" data-end=\"1128\"\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli data-start=\"1132\" data-end=\"1186\"\u003eGenuine OEM Dometic \/ Atwood replacement burner head\u003c\/li\u003e\n\u003cli data-start=\"1189\" data-end=\"1237\"\u003eDesigned for LP and Natural Gas furnace models\u003c\/li\u003e\n\u003cli data-start=\"1240\" data-end=\"1294\"\u003ePrecision fuel distribution for stable flame pattern\u003c\/li\u003e\n\u003cli data-start=\"1297\" data-end=\"1356\"\u003eHelps restore ignition reliability and heating efficiency\u003c\/li\u003e\n\u003cli data-start=\"1359\" data-end=\"1418\"\u003eDurable construction built for high-temperature operation\u003c\/li\u003e\n\u003cli data-start=\"1421\" data-end=\"1472\"\u003eManufactured to original equipment specifications\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1474\" data-end=\"1477\"\u003e\n\u003ch3 data-start=\"1479\" data-end=\"1508\"\u003eCompatible Furnace Models\u003c\/h3\u003e\n\u003cp data-start=\"1510\" data-end=\"1580\"\u003ePart \u003cstrong data-start=\"1515\" data-end=\"1524\"\u003e30209\u003c\/strong\u003e is compatible with the following Atwood furnace models:\u003c\/p\u003e\n\u003ch4 data-start=\"1582\" data-end=\"1613\"\u003e8900 Series – Generation I\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli data-start=\"1616\" data-end=\"1627\"\u003e8935-DC-I\u003c\/li\u003e\n\u003cli data-start=\"1630\" data-end=\"1641\"\u003e8935-AC-I\u003c\/li\u003e\n\u003cli data-start=\"1644\" data-end=\"1655\"\u003e8940-DC-I\u003c\/li\u003e\n\u003cli data-start=\"1658\" data-end=\"1669\"\u003e8940-AC-I\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-start=\"1671\" data-end=\"1703\"\u003e8900 Series – Generation II\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli data-start=\"1706\" data-end=\"1718\"\u003e8935-DC-II\u003c\/li\u003e\n\u003cli data-start=\"1721\" data-end=\"1733\"\u003e8935-AC-II\u003c\/li\u003e\n\u003cli data-start=\"1736\" data-end=\"1748\"\u003e8940-DC-II\u003c\/li\u003e\n\u003cli data-start=\"1751\" data-end=\"1763\"\u003e8940-AC-II\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-start=\"1765\" data-end=\"1798\"\u003e8900 Series – Generation III\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli data-start=\"1801\" data-end=\"1814\"\u003e8935-DC-III\u003c\/li\u003e\n\u003cli data-start=\"1817\" data-end=\"1830\"\u003e8935-AC-III\u003c\/li\u003e\n\u003cli data-start=\"1833\" data-end=\"1846\"\u003e8940-DC-III\u003c\/li\u003e\n\u003cli data-start=\"1849\" data-end=\"1862\"\u003e8940-AC-III\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-start=\"1864\" data-end=\"1880\"\u003eAFLA Series\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli data-start=\"1883\" data-end=\"1894\"\u003eAFLA35211\u003c\/li\u003e\n\u003cli data-start=\"1897\" data-end=\"1908\"\u003eAFLA40211\u003c\/li\u003e\n\u003cli data-start=\"1911\" data-end=\"1922\"\u003eAFLA35221\u003c\/li\u003e\n\u003cli data-start=\"1925\" data-end=\"1936\"\u003eAFLA40221\u003c\/li\u003e\n\u003cli data-start=\"1939\" data-end=\"1950\"\u003eAFLA35231\u003c\/li\u003e\n\u003cli data-start=\"1953\" data-end=\"1964\"\u003eAFLA40231\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-start=\"1966\" data-end=\"1982\"\u003eAFLD Series\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli data-start=\"1985\" data-end=\"1996\"\u003eAFLD35111\u003c\/li\u003e\n\u003cli data-start=\"1999\" data-end=\"2010\"\u003eAFLD40111\u003c\/li\u003e\n\u003cli data-start=\"2013\" data-end=\"2024\"\u003eAFLD35121\u003c\/li\u003e\n\u003cli data-start=\"2027\" data-end=\"2038\"\u003eAFLD40121\u003c\/li\u003e\n\u003cli data-start=\"2041\" data-end=\"2052\"\u003eAFLD35131\u003c\/li\u003e\n\u003cli data-start=\"2055\" data-end=\"2066\"\u003eAFLD40131\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cblockquote data-start=\"2068\" data-end=\"2168\"\u003e\n\u003cp data-start=\"2070\" data-end=\"2168\"\u003eAlways verify your furnace model number on the data plate before ordering to ensure compatibility.\u003c\/p\u003e\n\u003c\/blockquote\u003e\n\u003chr data-start=\"2170\" data-end=\"2173\"\u003e\n\u003ch3 data-start=\"2175\" data-end=\"2219\"\u003eWhen Should You Replace the Burner Head?\u003c\/h3\u003e\n\u003cp data-start=\"2221\" data-end=\"2279\"\u003eYou may need to replace the burner head if you experience:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli data-start=\"2283\" data-end=\"2301\"\u003eDelayed ignition\u003c\/li\u003e\n\u003cli data-start=\"2304\" data-end=\"2330\"\u003eUneven or unstable flame\u003c\/li\u003e\n\u003cli data-start=\"2333\" data-end=\"2377\"\u003eSoot buildup inside the combustion chamber\u003c\/li\u003e\n\u003cli data-start=\"2380\" data-end=\"2409\"\u003eFurnace failing to stay lit\u003c\/li\u003e\n\u003cli data-start=\"2412\" data-end=\"2464\"\u003eCorrosion or visible damage to the burner assembly\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"2466\" data-end=\"2566\"\u003eReplacing a worn burner head restores proper combustion and helps maintain safe furnace performance.\u003c\/p\u003e\n\u003chr data-start=\"2568\" data-end=\"2571\"\u003e\n\u003ch3 data-start=\"2573\" data-end=\"2599\"\u003eProduct Specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli data-start=\"2603\" data-end=\"2639\"\u003e\n\u003cstrong data-start=\"2603\" data-end=\"2620\"\u003eManufacturer:\u003c\/strong\u003e Dometic \/ Atwood\u003c\/li\u003e\n\u003cli data-start=\"2642\" data-end=\"2666\"\u003e\n\u003cstrong data-start=\"2642\" data-end=\"2658\"\u003ePart Number:\u003c\/strong\u003e 30209\u003c\/li\u003e\n\u003cli data-start=\"2669\" data-end=\"2697\"\u003e\n\u003cstrong data-start=\"2669\" data-end=\"2683\"\u003eComponent:\u003c\/strong\u003e Burner Head\u003c\/li\u003e\n\u003cli data-start=\"2700\" data-end=\"2746\"\u003e\n\u003cstrong data-start=\"2700\" data-end=\"2723\"\u003eFuel Compatibility:\u003c\/strong\u003e LP Gas \u0026amp; Natural Gas\u003c\/li\u003e\n\u003cli data-start=\"2749\" data-end=\"2810\"\u003e\n\u003cstrong data-start=\"2749\" data-end=\"2771\"\u003eCompatible Series:\u003c\/strong\u003e 8900 Series (I, II, III), AFLA, AFLD\u003c\/li\u003e\n\u003cli data-start=\"2813\" data-end=\"2845\"\u003e\n\u003cstrong data-start=\"2813\" data-end=\"2826\"\u003eIncludes:\u003c\/strong\u003e Burner head only\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2847\" data-end=\"2850\"\u003e\n\u003ch2 data-start=\"2852\" data-end=\"2887\"\u003eFrequently Asked Questions (FAQ)\u003c\/h2\u003e\n\u003ch3 data-start=\"2889\" data-end=\"2955\"\u003eQ: Is this compatible with both LP and natural gas furnaces?\u003c\/h3\u003e\n\u003cp data-start=\"2956\" data-end=\"3052\"\u003eA: Yes. Part 30209 is designed for select Atwood LP and natural gas furnace models listed above.\u003c\/p\u003e\n\u003chr data-start=\"3054\" data-end=\"3057\"\u003e\n\u003ch3 data-start=\"3059\" data-end=\"3111\"\u003eQ: Does this include the full burner assembly?\u003c\/h3\u003e\n\u003cp data-start=\"3112\" data-end=\"3164\"\u003eA: No. This listing is for the \u003cstrong data-start=\"3143\" data-end=\"3163\"\u003eburner head only\u003c\/strong\u003e.\u003c\/p\u003e\n\u003chr data-start=\"3166\" data-end=\"3169\"\u003e\n\u003ch3 data-start=\"3171\" data-end=\"3211\"\u003eQ: How do I confirm compatibility?\u003c\/h3\u003e\n\u003cp data-start=\"3212\" data-end=\"3329\"\u003eA: Locate the exact furnace model number on your unit data plate and compare it with the compatibility list provided.\u003c\/p\u003e\n\u003chr data-start=\"3331\" data-end=\"3334\"\u003e\n\u003ch3 data-start=\"3336\" data-end=\"3365\"\u003eQ: Is this an OEM part?\u003c\/h3\u003e\n\u003cp data-start=\"3366\" data-end=\"3432\"\u003eA: Yes. 30209 is a genuine Dometic \/ Atwood replacement component.\u003c\/p\u003e","brand":"RV Furnace Guys","offers":[{"title":"Default Title","offer_id":47854729036017,"sku":null,"price":55.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0784\/4941\/0289\/files\/30209.jpg?v=1772308954"},{"product_id":"dometic-atwood-30887-furnace-burner-orifice-48-nat","title":"Dometic \/ Atwood 30887 Furnace Burner Orifice – #48 NAT","description":"\u003ch2 data-start=\"105\" data-end=\"165\"\u003eDometic \/ Atwood 30887 Furnace Burner Orifice – #48 NAT\u003c\/h2\u003e\n\u003cp data-start=\"166\" data-end=\"193\"\u003e\u003cstrong data-start=\"166\" data-end=\"193\"\u003eGenuine OEM Replacement\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"195\" data-end=\"311\"\u003e\u003cstrong data-start=\"195\" data-end=\"211\"\u003ePart Number:\u003c\/strong\u003e 30887\u003cbr data-start=\"217\" data-end=\"220\"\u003e\u003cstrong data-start=\"220\" data-end=\"237\"\u003eProduct Type:\u003c\/strong\u003e Furnace Burner Orifice\u003cbr data-start=\"260\" data-end=\"263\"\u003e\u003cstrong data-start=\"263\" data-end=\"272\"\u003eSize:\u003c\/strong\u003e #48\u003cbr data-start=\"276\" data-end=\"279\"\u003e\u003cstrong data-start=\"279\" data-end=\"293\"\u003eFuel Type:\u003c\/strong\u003e Natural Gas (NAT)\u003c\/p\u003e\n\u003chr data-start=\"313\" data-end=\"316\"\u003e\n\u003ch3 data-start=\"318\" data-end=\"338\"\u003eProduct Overview\u003c\/h3\u003e\n\u003cp data-start=\"340\" data-end=\"517\"\u003eThe \u003cstrong data-start=\"344\" data-end=\"403\"\u003eDometic \/ Atwood 30887 Furnace Burner Orifice (#48 NAT)\u003c\/strong\u003e is a genuine OEM replacement component designed for use with select Atwood furnaces operating on \u003cstrong data-start=\"501\" data-end=\"516\"\u003enatural gas\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp data-start=\"519\" data-end=\"772\"\u003eThe burner orifice precisely meters fuel flow into the burner assembly, ensuring proper combustion, stable flame characteristics, and safe furnace operation. Part 30887 is calibrated to a \u003cstrong data-start=\"707\" data-end=\"727\"\u003e#48 orifice size\u003c\/strong\u003e specifically for natural gas configurations.\u003c\/p\u003e\n\u003cp data-start=\"774\" data-end=\"944\"\u003eReplacing a damaged, clogged, or improperly sized orifice helps restore correct fuel-to-air ratio, improve ignition performance, and maintain efficient heating operation.\u003c\/p\u003e\n\u003cp data-start=\"946\" data-end=\"1075\"\u003eManufactured to original equipment specifications, this OEM orifice provides accurate fitment and reliable long-term performance.\u003c\/p\u003e\n\u003chr data-start=\"1077\" data-end=\"1080\"\u003e\n\u003ch3 data-start=\"1082\" data-end=\"1098\"\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli data-start=\"1102\" data-end=\"1149\"\u003eGenuine OEM Dometic \/ Atwood replacement part\u003c\/li\u003e\n\u003cli data-start=\"1152\" data-end=\"1194\"\u003eBurner orifice calibrated to \u003cstrong data-start=\"1181\" data-end=\"1192\"\u003e#48 NAT\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1197\" data-end=\"1251\"\u003eDesigned specifically for natural gas furnace models\u003c\/li\u003e\n\u003cli data-start=\"1254\" data-end=\"1299\"\u003eEnsures proper fuel metering and combustion\u003c\/li\u003e\n\u003cli data-start=\"1302\" data-end=\"1345\"\u003ePrecision-machined for accurate flow rate\u003c\/li\u003e\n\u003cli data-start=\"1348\" data-end=\"1392\"\u003eBuilt to original equipment specifications\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1394\" data-end=\"1397\"\u003e\n\u003ch3 data-start=\"1399\" data-end=\"1426\"\u003eCompatible Applications\u003c\/h3\u003e\n\u003cp data-start=\"1428\" data-end=\"1534\"\u003ePart \u003cstrong data-start=\"1433\" data-end=\"1442\"\u003e30887\u003c\/strong\u003e is used in select \u003cstrong data-start=\"1461\" data-end=\"1498\"\u003eAtwood natural gas furnace models\u003c\/strong\u003e requiring a \u003cstrong data-start=\"1511\" data-end=\"1533\"\u003e#48 burner orifice\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cblockquote data-start=\"1536\" data-end=\"1745\"\u003e\n\u003cp data-start=\"1538\" data-end=\"1745\"\u003eImportant: Always verify your furnace fuel type (Natural Gas vs LP) and confirm the specified orifice size before ordering. Installing the incorrect orifice size can affect combustion performance and safety.\u003c\/p\u003e\n\u003c\/blockquote\u003e\n\u003cp data-start=\"1747\" data-end=\"1856\"\u003eIf you are unsure, check the data plate on your furnace or consult your manufacturer’s service documentation.\u003c\/p\u003e\n\u003chr data-start=\"1858\" data-end=\"1861\"\u003e\n\u003ch3 data-start=\"1863\" data-end=\"1910\"\u003eWhen Should You Replace the Burner Orifice?\u003c\/h3\u003e\n\u003cp data-start=\"1912\" data-end=\"1974\"\u003eYou may need to replace your burner orifice if you experience:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli data-start=\"1978\" data-end=\"1996\"\u003eDelayed ignition\u003c\/li\u003e\n\u003cli data-start=\"1999\" data-end=\"2023\"\u003eWeak or unstable flame\u003c\/li\u003e\n\u003cli data-start=\"2026\" data-end=\"2055\"\u003eFurnace failing to stay lit\u003c\/li\u003e\n\u003cli data-start=\"2058\" data-end=\"2110\"\u003eImproper fuel conversion (LP to NAT or vice versa)\u003c\/li\u003e\n\u003cli data-start=\"2113\" data-end=\"2144\"\u003eVisible blockage or corrosion\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"2146\" data-end=\"2234\"\u003eUsing the correct OEM orifice size is critical for proper combustion and safe operation.\u003c\/p\u003e\n\u003chr data-start=\"2236\" data-end=\"2239\"\u003e\n\u003ch3 data-start=\"2241\" data-end=\"2267\"\u003eProduct Specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli data-start=\"2271\" data-end=\"2307\"\u003e\n\u003cstrong data-start=\"2271\" data-end=\"2288\"\u003eManufacturer:\u003c\/strong\u003e Dometic \/ Atwood\u003c\/li\u003e\n\u003cli data-start=\"2310\" data-end=\"2334\"\u003e\n\u003cstrong data-start=\"2310\" data-end=\"2326\"\u003ePart Number:\u003c\/strong\u003e 30887\u003c\/li\u003e\n\u003cli data-start=\"2337\" data-end=\"2368\"\u003e\n\u003cstrong data-start=\"2337\" data-end=\"2351\"\u003eComponent:\u003c\/strong\u003e Burner Orifice\u003c\/li\u003e\n\u003cli data-start=\"2371\" data-end=\"2394\"\u003e\n\u003cstrong data-start=\"2371\" data-end=\"2388\"\u003eOrifice Size:\u003c\/strong\u003e #48\u003c\/li\u003e\n\u003cli data-start=\"2397\" data-end=\"2431\"\u003e\n\u003cstrong data-start=\"2397\" data-end=\"2411\"\u003eFuel Type:\u003c\/strong\u003e Natural Gas (NAT)\u003c\/li\u003e\n\u003cli data-start=\"2434\" data-end=\"2469\"\u003e\n\u003cstrong data-start=\"2434\" data-end=\"2447\"\u003eIncludes:\u003c\/strong\u003e Burner orifice only\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2471\" data-end=\"2474\"\u003e\n\u003ch2 data-start=\"2476\" data-end=\"2511\"\u003eFrequently Asked Questions (FAQ)\u003c\/h2\u003e\n\u003ch3 data-start=\"2513\" data-end=\"2547\"\u003eQ: What does “#48 NAT” mean?\u003c\/h3\u003e\n\u003cp data-start=\"2548\" data-end=\"2657\"\u003eA: #48 refers to the orifice size calibration, and NAT indicates it is designed for natural gas applications.\u003c\/p\u003e\n\u003chr data-start=\"2659\" data-end=\"2662\"\u003e\n\u003ch3 data-start=\"2664\" data-end=\"2714\"\u003eQ: Will this work for LP (propane) furnaces?\u003c\/h3\u003e\n\u003cp data-start=\"2715\" data-end=\"2807\"\u003eA: No. LP furnaces require a different orifice size calibrated specifically for propane gas.\u003c\/p\u003e\n\u003chr data-start=\"2809\" data-end=\"2812\"\u003e\n\u003ch3 data-start=\"2814\" data-end=\"2843\"\u003eQ: Is this an OEM part?\u003c\/h3\u003e\n\u003cp data-start=\"2844\" data-end=\"2915\"\u003eA: Yes. Part 30887 is a genuine Dometic \/ Atwood replacement component.\u003c\/p\u003e\n\u003chr data-start=\"2917\" data-end=\"2920\"\u003e\n\u003ch3 data-start=\"2922\" data-end=\"2988\"\u003eQ: How do I confirm the correct orifice size for my furnace?\u003c\/h3\u003e\n\u003cp data-start=\"2989\" data-end=\"3101\"\u003eA: Check your furnace data plate or service manual for the specified orifice size and fuel type before ordering.\u003c\/p\u003e","brand":"RV Furnace Guys","offers":[{"title":"Default Title","offer_id":47854731198705,"sku":null,"price":12.49,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0784\/4941\/0289\/files\/30887.jpg?v=1772309493"},{"product_id":"dometic-atwood-33128-furnace-combustion-wheel-8500-8900-series","title":"Dometic \/ Atwood 33128 Furnace Combustion Wheel – 8500, 8900 Series","description":"\u003ch2 data-start=\"134\" data-end=\"207\"\u003eDometic \/ Atwood 33128 Furnace Combustion Wheel – 8500 \u0026amp; 8900 Series\u003c\/h2\u003e\n\u003cp data-start=\"208\" data-end=\"235\"\u003e\u003cstrong data-start=\"208\" data-end=\"235\"\u003eGenuine OEM Replacement\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"237\" data-end=\"306\"\u003e\u003cstrong data-start=\"237\" data-end=\"253\"\u003ePart Number:\u003c\/strong\u003e 33128\u003cbr data-start=\"259\" data-end=\"262\"\u003e\u003cstrong data-start=\"262\" data-end=\"279\"\u003eProduct Type:\u003c\/strong\u003e Furnace Combustion Wheel\u003c\/p\u003e\n\u003chr data-start=\"308\" data-end=\"311\"\u003e\n\u003ch3 data-start=\"313\" data-end=\"333\"\u003eProduct Overview\u003c\/h3\u003e\n\u003cp data-start=\"335\" data-end=\"639\"\u003eThe \u003cstrong data-start=\"339\" data-end=\"390\"\u003eDometic \/ Atwood 33128 Furnace Combustion Wheel\u003c\/strong\u003e is a genuine OEM replacement designed for select \u003cstrong data-start=\"440\" data-end=\"480\"\u003eAtwood 8500 and 8900 series furnaces\u003c\/strong\u003e. The combustion wheel is responsible for drawing in combustion air and expelling exhaust gases, ensuring proper burner operation and safe furnace performance.\u003c\/p\u003e\n\u003cp data-start=\"641\" data-end=\"876\"\u003eA properly functioning combustion wheel maintains correct airflow through the combustion chamber. If cracked, warped, or imbalanced, the furnace may experience ignition failures, poor flame quality, excessive noise, or shutdown issues.\u003c\/p\u003e\n\u003cp data-start=\"878\" data-end=\"1022\"\u003eManufactured to original equipment specifications, Part 33128 restores proper combustion airflow and supports safe, efficient furnace operation.\u003c\/p\u003e\n\u003chr data-start=\"1024\" data-end=\"1027\"\u003e\n\u003ch3 data-start=\"1029\" data-end=\"1045\"\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli data-start=\"1049\" data-end=\"1096\"\u003eGenuine OEM Dometic \/ Atwood replacement part\u003c\/li\u003e\n\u003cli data-start=\"1099\" data-end=\"1143\"\u003eDesigned for 8500 and 8900 series furnaces\u003c\/li\u003e\n\u003cli data-start=\"1146\" data-end=\"1201\"\u003eEnsures proper combustion air intake and exhaust flow\u003c\/li\u003e\n\u003cli data-start=\"1204\" data-end=\"1252\"\u003ePrecision-balanced for smooth, quiet operation\u003c\/li\u003e\n\u003cli data-start=\"1255\" data-end=\"1304\"\u003eDurable construction for high-heat environments\u003c\/li\u003e\n\u003cli data-start=\"1307\" data-end=\"1346\"\u003eBuilt to original equipment standards\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1348\" data-end=\"1351\"\u003e\n\u003ch3 data-start=\"1353\" data-end=\"1382\"\u003eCompatible Furnace Models\u003c\/h3\u003e\n\u003cp data-start=\"1384\" data-end=\"1418\"\u003ePart \u003cstrong data-start=\"1389\" data-end=\"1398\"\u003e33128\u003c\/strong\u003e is compatible with:\u003c\/p\u003e\n\u003cp data-start=\"1420\" data-end=\"1435\"\u003e\u003cstrong data-start=\"1420\" data-end=\"1435\"\u003e8500 Series\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli data-start=\"1438\" data-end=\"1447\"\u003e8500 II\u003c\/li\u003e\n\u003cli data-start=\"1450\" data-end=\"1460\"\u003e8500 III\u003c\/li\u003e\n\u003cli data-start=\"1463\" data-end=\"1472\"\u003e8500 IV\u003c\/li\u003e\n\u003cli data-start=\"1475\" data-end=\"1484\"\u003e8500 LD\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"1486\" data-end=\"1501\"\u003e\u003cstrong data-start=\"1486\" data-end=\"1501\"\u003e8900 Series\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"1502\" data-end=\"1521\"\u003e\n\u003cli data-start=\"1502\" data-end=\"1521\"\u003e\n\u003cp data-start=\"1504\" data-end=\"1521\"\u003eAll 8900 models\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cblockquote data-start=\"1523\" data-end=\"1628\"\u003e\n\u003cp data-start=\"1525\" data-end=\"1628\"\u003eAlways verify your furnace model number on the unit data plate before ordering to ensure compatibility.\u003c\/p\u003e\n\u003c\/blockquote\u003e\n\u003chr data-start=\"1630\" data-end=\"1633\"\u003e\n\u003ch3 data-start=\"1635\" data-end=\"1684\"\u003eWhen Should You Replace the Combustion Wheel?\u003c\/h3\u003e\n\u003cp data-start=\"1686\" data-end=\"1745\"\u003eYou may need to replace the combustion wheel if you notice:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli data-start=\"1749\" data-end=\"1777\"\u003eDelayed or failed ignition\u003c\/li\u003e\n\u003cli data-start=\"1780\" data-end=\"1803\"\u003eUnusual startup noise\u003c\/li\u003e\n\u003cli data-start=\"1806\" data-end=\"1825\"\u003eFurnace vibration\u003c\/li\u003e\n\u003cli data-start=\"1828\" data-end=\"1856\"\u003eInconsistent flame pattern\u003c\/li\u003e\n\u003cli data-start=\"1859\" data-end=\"1887\"\u003eVisible damage or cracking\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"1889\" data-end=\"1994\"\u003eReplacing a worn combustion wheel helps maintain proper draft, combustion efficiency, and safe operation.\u003c\/p\u003e\n\u003chr data-start=\"1996\" data-end=\"1999\"\u003e\n\u003ch3 data-start=\"2001\" data-end=\"2027\"\u003eProduct Specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli data-start=\"2031\" data-end=\"2067\"\u003e\n\u003cstrong data-start=\"2031\" data-end=\"2048\"\u003eManufacturer:\u003c\/strong\u003e Dometic \/ Atwood\u003c\/li\u003e\n\u003cli data-start=\"2070\" data-end=\"2094\"\u003e\n\u003cstrong data-start=\"2070\" data-end=\"2086\"\u003ePart Number:\u003c\/strong\u003e 33128\u003c\/li\u003e\n\u003cli data-start=\"2097\" data-end=\"2130\"\u003e\n\u003cstrong data-start=\"2097\" data-end=\"2111\"\u003eComponent:\u003c\/strong\u003e Combustion Wheel\u003c\/li\u003e\n\u003cli data-start=\"2133\" data-end=\"2198\"\u003e\n\u003cstrong data-start=\"2133\" data-end=\"2155\"\u003eCompatible Series:\u003c\/strong\u003e 8500 II, III, IV, LD and all 8900 models\u003c\/li\u003e\n\u003cli data-start=\"2201\" data-end=\"2238\"\u003e\n\u003cstrong data-start=\"2201\" data-end=\"2214\"\u003eIncludes:\u003c\/strong\u003e Combustion wheel only\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2240\" data-end=\"2243\"\u003e\n\u003ch2 data-start=\"2245\" data-end=\"2280\"\u003eFrequently Asked Questions (FAQ)\u003c\/h2\u003e\n\u003ch3 data-start=\"2282\" data-end=\"2323\"\u003eQ: What does a combustion wheel do?\u003c\/h3\u003e\n\u003cp data-start=\"2324\" data-end=\"2419\"\u003eA: It pulls combustion air into the burner chamber and pushes exhaust gases out of the furnace.\u003c\/p\u003e\n\u003chr data-start=\"2421\" data-end=\"2424\"\u003e\n\u003ch3 data-start=\"2426\" data-end=\"2481\"\u003eQ: Is this the same as the interior blower wheel?\u003c\/h3\u003e\n\u003cp data-start=\"2482\" data-end=\"2597\"\u003eA: No. The combustion wheel handles burner airflow. The blower wheel circulates heated air into the RV living area.\u003c\/p\u003e\n\u003chr data-start=\"2599\" data-end=\"2602\"\u003e\n\u003ch3 data-start=\"2604\" data-end=\"2654\"\u003eQ: Which furnace generations use Part 33128?\u003c\/h3\u003e\n\u003cp data-start=\"2655\" data-end=\"2717\"\u003eA: It fits 8500 II, III, IV, LD, and all 8900 series furnaces.\u003c\/p\u003e\n\u003chr data-start=\"2719\" data-end=\"2722\"\u003e\n\u003ch3 data-start=\"2724\" data-end=\"2753\"\u003eQ: Is this an OEM part?\u003c\/h3\u003e\n\u003cp data-start=\"2754\" data-end=\"2815\"\u003eA: Yes. 33128 is a genuine Dometic \/ Atwood replacement part.\u003c\/p\u003e","brand":"RV Furnace Guys","offers":[{"title":"Default Title","offer_id":47854732640497,"sku":null,"price":14.95,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0784\/4941\/0289\/files\/33128.png?v=1772309831"},{"product_id":"dometic-atwood-33124-furnace-combustion-wheel-79-80-series","title":"Dometic \/ Atwood 33124 Furnace Combustion Wheel – 79 \u0026 80 Series - Special Order","description":"\u003ch2 data-start=\"239\" data-end=\"308\"\u003eDometic \/ Atwood 33124 Furnace Combustion Wheel – 79 \u0026amp; 80 Series\u003c\/h2\u003e\n\u003cp data-start=\"309\" data-end=\"395\"\u003e\u003cstrong data-start=\"309\" data-end=\"365\"\u003eSpecial Order Item (7–14 Business Days for Shipping)\u003c\/strong\u003e\u003cbr data-start=\"365\" data-end=\"368\"\u003e\u003cstrong data-start=\"368\" data-end=\"395\"\u003eGenuine OEM Replacement\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"397\" data-end=\"523\"\u003e\u003cstrong data-start=\"397\" data-end=\"413\"\u003ePart Number:\u003c\/strong\u003e 33124\u003cbr data-start=\"419\" data-end=\"422\"\u003e\u003cstrong data-start=\"422\" data-end=\"439\"\u003eProduct Type:\u003c\/strong\u003e Furnace Combustion Wheel\u003cbr data-start=\"464\" data-end=\"467\"\u003e\u003cstrong data-start=\"467\" data-end=\"483\"\u003eApplication:\u003c\/strong\u003e Atwood 79 Series \u0026amp; 80 Series Furnaces\u003c\/p\u003e\n\u003chr data-start=\"525\" data-end=\"528\"\u003e\n\u003ch3 data-start=\"530\" data-end=\"550\"\u003eProduct Overview\u003c\/h3\u003e\n\u003cp data-start=\"552\" data-end=\"873\"\u003eThe \u003cstrong data-start=\"556\" data-end=\"607\"\u003eDometic \/ Atwood 33124 Furnace Combustion Wheel\u003c\/strong\u003e is a genuine OEM replacement component designed for select \u003cstrong data-start=\"667\" data-end=\"703\"\u003eAtwood 79 and 80 Series furnaces\u003c\/strong\u003e. The combustion wheel is responsible for drawing combustion air into the burner chamber and expelling exhaust gases, ensuring proper ignition and safe furnace operation.\u003c\/p\u003e\n\u003cp data-start=\"875\" data-end=\"1127\"\u003eA damaged or worn combustion wheel can cause ignition failures, improper flame characteristics, noisy startup, or airflow-related shutdowns. Replacing it with OEM Part 33124 restores proper combustion airflow and maintains reliable furnace performance.\u003c\/p\u003e\n\u003cp data-start=\"1129\" data-end=\"1280\"\u003eManufactured to original equipment specifications, this component is precision-balanced for smooth and dependable operation in RV heating applications.\u003c\/p\u003e\n\u003cp data-start=\"1282\" data-end=\"1380\"\u003e\u003cstrong data-start=\"1282\" data-end=\"1298\"\u003ePlease Note:\u003c\/strong\u003e This is a \u003cem data-start=\"1309\" data-end=\"1324\"\u003eSpecial Order\u003c\/em\u003e part and typically ships within \u003cstrong data-start=\"1357\" data-end=\"1379\"\u003e7–14 business days\u003c\/strong\u003e.\u003c\/p\u003e\n\u003chr data-start=\"1382\" data-end=\"1385\"\u003e\n\u003ch3 data-start=\"1387\" data-end=\"1403\"\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli data-start=\"1407\" data-end=\"1454\"\u003eGenuine OEM Dometic \/ Atwood replacement part\u003c\/li\u003e\n\u003cli data-start=\"1457\" data-end=\"1497\"\u003eDesigned for 79 and 80 Series furnaces\u003c\/li\u003e\n\u003cli data-start=\"1500\" data-end=\"1555\"\u003eEnsures proper combustion air intake and exhaust flow\u003c\/li\u003e\n\u003cli data-start=\"1558\" data-end=\"1611\"\u003ePrecision-balanced for smooth startup and operation\u003c\/li\u003e\n\u003cli data-start=\"1614\" data-end=\"1670\"\u003eDurable construction for high-temperature environments\u003c\/li\u003e\n\u003cli data-start=\"1673\" data-end=\"1719\"\u003eManufactured to original equipment standards\u003c\/li\u003e\n\u003cli data-start=\"1722\" data-end=\"1774\"\u003eSpecial Order item (7–14 business days for shipping)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1776\" data-end=\"1779\"\u003e\n\u003ch3 data-start=\"1781\" data-end=\"1810\"\u003eCompatible Furnace Models\u003c\/h3\u003e\n\u003cp data-start=\"1812\" data-end=\"1846\"\u003ePart \u003cstrong data-start=\"1817\" data-end=\"1826\"\u003e33124\u003c\/strong\u003e is compatible with:\u003c\/p\u003e\n\u003cp data-start=\"1848\" data-end=\"1861\"\u003e\u003cstrong data-start=\"1848\" data-end=\"1861\"\u003e79 Series\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli data-start=\"1864\" data-end=\"1870\"\u003e7912\u003c\/li\u003e\n\u003cli data-start=\"1873\" data-end=\"1882\"\u003e7912-II\u003c\/li\u003e\n\u003cli data-start=\"1885\" data-end=\"1891\"\u003e7916\u003c\/li\u003e\n\u003cli data-start=\"1894\" data-end=\"1903\"\u003e7916-II\u003c\/li\u003e\n\u003cli data-start=\"1906\" data-end=\"1912\"\u003e7920\u003c\/li\u003e\n\u003cli data-start=\"1915\" data-end=\"1924\"\u003e7920-II\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"1926\" data-end=\"1939\"\u003e\u003cstrong data-start=\"1926\" data-end=\"1939\"\u003e80 Series\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli data-start=\"1942\" data-end=\"1948\"\u003e8012\u003c\/li\u003e\n\u003cli data-start=\"1951\" data-end=\"1960\"\u003e8012-II\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cblockquote data-start=\"1962\" data-end=\"2062\"\u003e\n\u003cp data-start=\"1964\" data-end=\"2062\"\u003eAlways verify your furnace model number on the data plate before ordering to ensure compatibility.\u003c\/p\u003e\n\u003c\/blockquote\u003e\n\u003chr data-start=\"2064\" data-end=\"2067\"\u003e\n\u003ch3 data-start=\"2069\" data-end=\"2118\"\u003eWhen Should You Replace the Combustion Wheel?\u003c\/h3\u003e\n\u003cp data-start=\"2120\" data-end=\"2179\"\u003eYou may need to replace the combustion wheel if you notice:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli data-start=\"2183\" data-end=\"2211\"\u003eDelayed or failed ignition\u003c\/li\u003e\n\u003cli data-start=\"2214\" data-end=\"2239\"\u003eExcessive furnace noise\u003c\/li\u003e\n\u003cli data-start=\"2242\" data-end=\"2268\"\u003eVibration during startup\u003c\/li\u003e\n\u003cli data-start=\"2271\" data-end=\"2299\"\u003eInconsistent flame pattern\u003c\/li\u003e\n\u003cli data-start=\"2302\" data-end=\"2336\"\u003eVisible cracking or blade damage\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"2338\" data-end=\"2430\"\u003eReplacing a worn combustion wheel restores proper draft and supports safe furnace operation.\u003c\/p\u003e\n\u003chr data-start=\"2432\" data-end=\"2435\"\u003e\n\u003ch3 data-start=\"2437\" data-end=\"2463\"\u003eProduct Specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli data-start=\"2467\" data-end=\"2503\"\u003e\n\u003cstrong data-start=\"2467\" data-end=\"2484\"\u003eManufacturer:\u003c\/strong\u003e Dometic \/ Atwood\u003c\/li\u003e\n\u003cli data-start=\"2506\" data-end=\"2530\"\u003e\n\u003cstrong data-start=\"2506\" data-end=\"2522\"\u003ePart Number:\u003c\/strong\u003e 33124\u003c\/li\u003e\n\u003cli data-start=\"2533\" data-end=\"2566\"\u003e\n\u003cstrong data-start=\"2533\" data-end=\"2547\"\u003eComponent:\u003c\/strong\u003e Combustion Wheel\u003c\/li\u003e\n\u003cli data-start=\"2569\" data-end=\"2608\"\u003e\n\u003cstrong data-start=\"2569\" data-end=\"2591\"\u003eCompatible Series:\u003c\/strong\u003e 79 \u0026amp; 80 Series\u003c\/li\u003e\n\u003cli data-start=\"2611\" data-end=\"2648\"\u003e\n\u003cstrong data-start=\"2611\" data-end=\"2624\"\u003eIncludes:\u003c\/strong\u003e Combustion wheel only\u003c\/li\u003e\n\u003cli data-start=\"2651\" data-end=\"2705\"\u003e\n\u003cstrong data-start=\"2651\" data-end=\"2668\"\u003eAvailability:\u003c\/strong\u003e \u003cem data-start=\"2669\" data-end=\"2705\"\u003eSpecial Order – 7–14 Business Days\u003c\/em\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2707\" data-end=\"2710\"\u003e\n\u003ch2 data-start=\"2712\" data-end=\"2747\"\u003eFrequently Asked Questions (FAQ)\u003c\/h2\u003e\n\u003ch3 data-start=\"2749\" data-end=\"2790\"\u003eQ: What does a combustion wheel do?\u003c\/h3\u003e\n\u003cp data-start=\"2791\" data-end=\"2923\"\u003eA: It moves combustion air into the burner chamber and pushes exhaust gases out of the furnace to support proper ignition and draft.\u003c\/p\u003e\n\u003chr data-start=\"2925\" data-end=\"2928\"\u003e\n\u003ch3 data-start=\"2930\" data-end=\"2976\"\u003eQ: Is this the same as the blower wheel?\u003c\/h3\u003e\n\u003cp data-start=\"2977\" data-end=\"3101\"\u003eA: No. The combustion wheel handles burner airflow and exhaust. The blower wheel circulates heated air into the RV interior.\u003c\/p\u003e\n\u003chr data-start=\"3103\" data-end=\"3106\"\u003e\n\u003ch3 data-start=\"3108\" data-end=\"3153\"\u003eQ: Which furnace series use Part 33124?\u003c\/h3\u003e\n\u003cp data-start=\"3154\" data-end=\"3205\"\u003eA: It fits Atwood 79 Series and 80 Series furnaces.\u003c\/p\u003e\n\u003chr data-start=\"3207\" data-end=\"3210\"\u003e\n\u003ch3 data-start=\"3212\" data-end=\"3254\"\u003eQ: Why is this marked Special Order?\u003c\/h3\u003e\n\u003cp data-start=\"3255\" data-end=\"3404\"\u003eA: This part is not typically stocked for immediate shipment and must be ordered from the distributor. Estimated delivery time is 7–14 business days.\u003c\/p\u003e\n\u003chr data-start=\"3406\" data-end=\"3409\"\u003e\n\u003ch3 data-start=\"3411\" data-end=\"3457\"\u003eQ: Is this an OEM Dometic \/ Atwood part?\u003c\/h3\u003e\n\u003cp data-start=\"3458\" data-end=\"3511\"\u003eA: Yes. 33124 is a genuine OEM replacement component.\u003c\/p\u003e","brand":"RV Furnace Guys","offers":[{"title":"Default Title","offer_id":47854733132017,"sku":null,"price":29.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0784\/4941\/0289\/files\/33124.jpg?v=1772310042"},{"product_id":"dometic-atwood-31150-furnace-gas-valve-side-outlet-12v-dc","title":"Dometic \/ Atwood 31150 Furnace Gas Valve – Side Outlet – 12V DC","description":"\u003ch2 data-start=\"158\" data-end=\"226\"\u003eDometic \/ Atwood 31150 Furnace Gas Valve – Side Outlet – 12V DC\u003c\/h2\u003e\n\u003cp data-start=\"227\" data-end=\"254\"\u003e\u003cstrong data-start=\"227\" data-end=\"254\"\u003eGenuine OEM Replacement\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"256\" data-end=\"431\"\u003e\u003cstrong data-start=\"256\" data-end=\"272\"\u003ePart Number:\u003c\/strong\u003e 31150\u003cbr data-start=\"278\" data-end=\"281\"\u003e\u003cstrong data-start=\"281\" data-end=\"298\"\u003eProduct Type:\u003c\/strong\u003e Furnace Gas Valve\u003cbr data-start=\"316\" data-end=\"319\"\u003e\u003cstrong data-start=\"319\" data-end=\"331\"\u003eVoltage:\u003c\/strong\u003e 12 Volt DC\u003cbr data-start=\"342\" data-end=\"345\"\u003e\u003cstrong data-start=\"345\" data-end=\"370\"\u003eOutlet Configuration:\u003c\/strong\u003e Side Outlet\u003cbr data-start=\"382\" data-end=\"385\"\u003e\u003cstrong data-start=\"385\" data-end=\"401\"\u003eApplication:\u003c\/strong\u003e Atwood HydroFlame® Furnaces\u003c\/p\u003e\n\u003chr data-start=\"433\" data-end=\"436\"\u003e\n\u003ch3 data-start=\"438\" data-end=\"458\"\u003eProduct Overview\u003c\/h3\u003e\n\u003cp data-start=\"460\" data-end=\"617\"\u003eThe \u003cstrong data-start=\"464\" data-end=\"508\"\u003eDometic \/ Atwood 31150 Furnace Gas Valve\u003c\/strong\u003e is a genuine OEM replacement gas control valve designed for use with select \u003cstrong data-start=\"585\" data-end=\"616\"\u003eAtwood HydroFlame® furnaces\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp data-start=\"619\" data-end=\"928\"\u003eOperating on \u003cstrong data-start=\"632\" data-end=\"646\"\u003e12 Volt DC\u003c\/strong\u003e, this gas valve regulates propane flow to the burner assembly and works in conjunction with the furnace control board to ensure safe ignition and proper heating operation. The \u003cstrong data-start=\"823\" data-end=\"852\"\u003eside outlet configuration\u003c\/strong\u003e allows correct alignment with the burner tube on compatible furnace models.\u003c\/p\u003e\n\u003cp data-start=\"930\" data-end=\"1131\"\u003eA malfunctioning gas valve can cause ignition failure, inconsistent flame, or complete furnace shutdown. Replacing it with OEM Part 31150 restores proper fuel delivery and reliable heating performance.\u003c\/p\u003e\n\u003cp data-start=\"1133\" data-end=\"1263\"\u003eBuilt to original equipment specifications, this valve ensures safe operation and correct fuel flow within your RV heating system.\u003c\/p\u003e\n\u003chr data-start=\"1265\" data-end=\"1268\"\u003e\n\u003ch3 data-start=\"1270\" data-end=\"1286\"\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli data-start=\"1290\" data-end=\"1337\"\u003eGenuine OEM Dometic \/ Atwood replacement part\u003c\/li\u003e\n\u003cli data-start=\"1340\" data-end=\"1382\"\u003eDesigned for Atwood HydroFlame® furnaces\u003c\/li\u003e\n\u003cli data-start=\"1385\" data-end=\"1411\"\u003e\u003cstrong data-start=\"1385\" data-end=\"1409\"\u003e12 Volt DC operation\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli data-start=\"1414\" data-end=\"1445\"\u003e\u003cstrong data-start=\"1414\" data-end=\"1443\"\u003eSide outlet configuration\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli data-start=\"1448\" data-end=\"1496\"\u003eRegulates propane fuel flow to burner assembly\u003c\/li\u003e\n\u003cli data-start=\"1499\" data-end=\"1543\"\u003eEnsures safe and reliable ignition control\u003c\/li\u003e\n\u003cli data-start=\"1546\" data-end=\"1592\"\u003eManufactured to original equipment standards\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1594\" data-end=\"1597\"\u003e\n\u003ch3 data-start=\"1599\" data-end=\"1626\"\u003eCompatible Applications\u003c\/h3\u003e\n\u003cp data-start=\"1628\" data-end=\"1717\"\u003ePart \u003cstrong data-start=\"1633\" data-end=\"1642\"\u003e31150\u003c\/strong\u003e is designed for use with select \u003cstrong data-start=\"1675\" data-end=\"1706\"\u003eAtwood HydroFlame® furnaces\u003c\/strong\u003e utilizing:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli data-start=\"1721\" data-end=\"1737\"\u003e12V DC systems\u003c\/li\u003e\n\u003cli data-start=\"1740\" data-end=\"1777\"\u003eSide outlet gas valve configuration\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cblockquote data-start=\"1779\" data-end=\"1890\"\u003e\n\u003cp data-start=\"1781\" data-end=\"1890\"\u003eAlways verify your furnace model number and gas valve configuration before ordering to ensure proper fitment.\u003c\/p\u003e\n\u003c\/blockquote\u003e\n\u003chr data-start=\"1892\" data-end=\"1895\"\u003e\n\u003ch3 data-start=\"1897\" data-end=\"1939\"\u003eWhen Should You Replace the Gas Valve?\u003c\/h3\u003e\n\u003cp data-start=\"1941\" data-end=\"1997\"\u003eYou may need to replace the gas valve if you experience:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli data-start=\"2001\" data-end=\"2028\"\u003eFurnace failing to ignite\u003c\/li\u003e\n\u003cli data-start=\"2031\" data-end=\"2054\"\u003eNo gas flow to burner\u003c\/li\u003e\n\u003cli data-start=\"2057\" data-end=\"2089\"\u003eIntermittent heating operation\u003c\/li\u003e\n\u003cli data-start=\"2092\" data-end=\"2125\"\u003eIgnition attempts without flame\u003c\/li\u003e\n\u003cli data-start=\"2128\" data-end=\"2164\"\u003eInternal valve sticking or leakage\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"2166\" data-end=\"2234\"\u003eProper gas valve operation is critical for safe furnace performance.\u003c\/p\u003e\n\u003chr data-start=\"2236\" data-end=\"2239\"\u003e\n\u003ch3 data-start=\"2241\" data-end=\"2267\"\u003eProduct Specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli data-start=\"2271\" data-end=\"2307\"\u003e\n\u003cstrong data-start=\"2271\" data-end=\"2288\"\u003eManufacturer:\u003c\/strong\u003e Dometic \/ Atwood\u003c\/li\u003e\n\u003cli data-start=\"2310\" data-end=\"2334\"\u003e\n\u003cstrong data-start=\"2310\" data-end=\"2326\"\u003ePart Number:\u003c\/strong\u003e 31150\u003c\/li\u003e\n\u003cli data-start=\"2337\" data-end=\"2371\"\u003e\n\u003cstrong data-start=\"2337\" data-end=\"2351\"\u003eComponent:\u003c\/strong\u003e Furnace Gas Valve\u003c\/li\u003e\n\u003cli data-start=\"2374\" data-end=\"2399\"\u003e\n\u003cstrong data-start=\"2374\" data-end=\"2386\"\u003eVoltage:\u003c\/strong\u003e 12 Volt DC\u003c\/li\u003e\n\u003cli data-start=\"2402\" data-end=\"2432\"\u003e\n\u003cstrong data-start=\"2402\" data-end=\"2418\"\u003eOutlet Type:\u003c\/strong\u003e Side Outlet\u003c\/li\u003e\n\u003cli data-start=\"2435\" data-end=\"2481\"\u003e\n\u003cstrong data-start=\"2435\" data-end=\"2451\"\u003eApplication:\u003c\/strong\u003e Atwood HydroFlame® Furnaces\u003c\/li\u003e\n\u003cli data-start=\"2484\" data-end=\"2513\"\u003e\n\u003cstrong data-start=\"2484\" data-end=\"2498\"\u003eFuel Type:\u003c\/strong\u003e Propane (LP)\u003c\/li\u003e\n\u003cli data-start=\"2516\" data-end=\"2555\"\u003e\n\u003cstrong data-start=\"2516\" data-end=\"2529\"\u003eIncludes:\u003c\/strong\u003e Gas valve assembly only\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2557\" data-end=\"2560\"\u003e\n\u003ch2 data-start=\"2562\" data-end=\"2597\"\u003eFrequently Asked Questions (FAQ)\u003c\/h2\u003e\n\u003ch3 data-start=\"2599\" data-end=\"2636\"\u003eQ: Is this a 12-volt gas valve?\u003c\/h3\u003e\n\u003cp data-start=\"2637\" data-end=\"2699\"\u003eA: Yes. Part 31150 operates on a 12 Volt DC electrical system.\u003c\/p\u003e\n\u003chr data-start=\"2701\" data-end=\"2704\"\u003e\n\u003ch3 data-start=\"2706\" data-end=\"2744\"\u003eQ: What does “side outlet” mean?\u003c\/h3\u003e\n\u003cp data-start=\"2745\" data-end=\"2860\"\u003eA: The gas outlet port extends from the side of the valve body to align with compatible burner tube configurations.\u003c\/p\u003e\n\u003chr data-start=\"2862\" data-end=\"2865\"\u003e\n\u003ch3 data-start=\"2867\" data-end=\"2921\"\u003eQ: Is this compatible with natural gas furnaces?\u003c\/h3\u003e\n\u003cp data-start=\"2922\" data-end=\"3028\"\u003eA: This valve is designed for LP (propane) furnace systems. Always confirm your fuel type before ordering.\u003c\/p\u003e\n\u003chr data-start=\"3030\" data-end=\"3033\"\u003e\n\u003ch3 data-start=\"3035\" data-end=\"3064\"\u003eQ: Is this an OEM part?\u003c\/h3\u003e\n\u003cp data-start=\"3065\" data-end=\"3131\"\u003eA: Yes. 31150 is a genuine Dometic \/ Atwood replacement gas valve.\u003c\/p\u003e\n\u003chr data-start=\"3133\" data-end=\"3136\"\u003e\n\u003ch3 data-start=\"3138\" data-end=\"3178\"\u003eQ: How do I confirm compatibility?\u003c\/h3\u003e\n\u003cp data-start=\"3179\" data-end=\"3289\"\u003eA: Locate your furnace model number and verify that your existing valve is a 12V DC side-outlet configuration.\u003c\/p\u003e","brand":"RV Furnace Guys","offers":[{"title":"Default Title","offer_id":47854735327473,"sku":null,"price":96.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0784\/4941\/0289\/files\/31150.png?v=1772310697"},{"product_id":"dometic-atwood-31151-furnace-gas-valve-side-outlet-24v-ac","title":"Dometic \/ Atwood 31151 Furnace Gas Valve – Side Outlet – 24V AC - Special Order","description":"\u003ch2 data-start=\"211\" data-end=\"279\"\u003eDometic \/ Atwood 31151 Furnace Gas Valve – Side Outlet – 24V AC\u003c\/h2\u003e\n\u003cp data-start=\"280\" data-end=\"366\"\u003e\u003cstrong data-start=\"280\" data-end=\"336\"\u003eSpecial Order Item (7–14 Business Days for Shipping)\u003c\/strong\u003e\u003cbr data-start=\"336\" data-end=\"339\"\u003e\u003cstrong data-start=\"339\" data-end=\"366\"\u003eGenuine OEM Replacement\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"368\" data-end=\"543\"\u003e\u003cstrong data-start=\"368\" data-end=\"384\"\u003ePart Number:\u003c\/strong\u003e 31151\u003cbr data-start=\"390\" data-end=\"393\"\u003e\u003cstrong data-start=\"393\" data-end=\"410\"\u003eProduct Type:\u003c\/strong\u003e Furnace Gas Valve\u003cbr data-start=\"428\" data-end=\"431\"\u003e\u003cstrong data-start=\"431\" data-end=\"443\"\u003eVoltage:\u003c\/strong\u003e 24 Volt AC\u003cbr data-start=\"454\" data-end=\"457\"\u003e\u003cstrong data-start=\"457\" data-end=\"482\"\u003eOutlet Configuration:\u003c\/strong\u003e Side Outlet\u003cbr data-start=\"494\" data-end=\"497\"\u003e\u003cstrong data-start=\"497\" data-end=\"513\"\u003eApplication:\u003c\/strong\u003e Atwood HydroFlame® Furnaces\u003c\/p\u003e\n\u003chr data-start=\"545\" data-end=\"548\"\u003e\n\u003ch3 data-start=\"550\" data-end=\"570\"\u003eProduct Overview\u003c\/h3\u003e\n\u003cp data-start=\"572\" data-end=\"756\"\u003eThe \u003cstrong data-start=\"576\" data-end=\"620\"\u003eDometic \/ Atwood 31151 Furnace Gas Valve\u003c\/strong\u003e is a genuine OEM replacement gas control valve designed for select \u003cstrong data-start=\"688\" data-end=\"719\"\u003eAtwood HydroFlame® furnaces\u003c\/strong\u003e operating on \u003cstrong data-start=\"733\" data-end=\"755\"\u003e24 Volt AC systems\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp data-start=\"758\" data-end=\"1029\"\u003eThis gas valve regulates propane flow to the burner assembly and works in coordination with the furnace control system to ensure proper ignition and safe heating operation. The \u003cstrong data-start=\"935\" data-end=\"964\"\u003eside outlet configuration\u003c\/strong\u003e allows correct alignment with compatible burner tube assemblies.\u003c\/p\u003e\n\u003cp data-start=\"1031\" data-end=\"1248\"\u003eIf your furnace fails to ignite, delivers inconsistent flame, or shows no gas flow, a faulty gas valve may be the cause. Replacing it with OEM Part 31151 restores safe fuel delivery and dependable heating performance.\u003c\/p\u003e\n\u003cp data-start=\"1250\" data-end=\"1382\"\u003eManufactured to original equipment specifications, this component ensures proper operation in compatible HydroFlame furnace systems.\u003c\/p\u003e\n\u003cp data-start=\"1384\" data-end=\"1482\"\u003e\u003cstrong data-start=\"1384\" data-end=\"1400\"\u003ePlease Note:\u003c\/strong\u003e This is a \u003cem data-start=\"1411\" data-end=\"1426\"\u003eSpecial Order\u003c\/em\u003e item and typically ships within \u003cstrong data-start=\"1459\" data-end=\"1481\"\u003e7–14 business days\u003c\/strong\u003e.\u003c\/p\u003e\n\u003chr data-start=\"1484\" data-end=\"1487\"\u003e\n\u003ch3 data-start=\"1489\" data-end=\"1505\"\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli data-start=\"1509\" data-end=\"1556\"\u003eGenuine OEM Dometic \/ Atwood replacement part\u003c\/li\u003e\n\u003cli data-start=\"1559\" data-end=\"1601\"\u003eDesigned for Atwood HydroFlame® furnaces\u003c\/li\u003e\n\u003cli data-start=\"1604\" data-end=\"1630\"\u003e\u003cstrong data-start=\"1604\" data-end=\"1628\"\u003e24 Volt AC operation\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli data-start=\"1633\" data-end=\"1664\"\u003e\u003cstrong data-start=\"1633\" data-end=\"1662\"\u003eSide outlet configuration\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli data-start=\"1667\" data-end=\"1706\"\u003eRegulates propane fuel flow to burner\u003c\/li\u003e\n\u003cli data-start=\"1709\" data-end=\"1745\"\u003eEnsures reliable ignition sequence\u003c\/li\u003e\n\u003cli data-start=\"1748\" data-end=\"1792\"\u003eBuilt to original equipment specifications\u003c\/li\u003e\n\u003cli data-start=\"1795\" data-end=\"1847\"\u003eSpecial Order item (7–14 business days for shipping)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1849\" data-end=\"1852\"\u003e\n\u003ch3 data-start=\"1854\" data-end=\"1881\"\u003eCompatible Applications\u003c\/h3\u003e\n\u003cp data-start=\"1883\" data-end=\"1972\"\u003ePart \u003cstrong data-start=\"1888\" data-end=\"1897\"\u003e31151\u003c\/strong\u003e is designed for use with select \u003cstrong data-start=\"1930\" data-end=\"1961\"\u003eAtwood HydroFlame® furnaces\u003c\/strong\u003e requiring:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli data-start=\"1976\" data-end=\"1998\"\u003e24 Volt AC gas valve\u003c\/li\u003e\n\u003cli data-start=\"2001\" data-end=\"2028\"\u003eSide outlet configuration\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cblockquote data-start=\"2030\" data-end=\"2206\"\u003e\n\u003cp data-start=\"2032\" data-end=\"2206\"\u003eImportant: Always verify your furnace voltage (24V AC vs 12V DC) and outlet orientation before ordering. Installing the incorrect voltage valve will prevent proper operation.\u003c\/p\u003e\n\u003c\/blockquote\u003e\n\u003chr data-start=\"2208\" data-end=\"2211\"\u003e\n\u003ch3 data-start=\"2213\" data-end=\"2255\"\u003eWhen Should You Replace the Gas Valve?\u003c\/h3\u003e\n\u003cp data-start=\"2257\" data-end=\"2313\"\u003eYou may need to replace the gas valve if you experience:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli data-start=\"2317\" data-end=\"2358\"\u003eFurnace ignition attempts without flame\u003c\/li\u003e\n\u003cli data-start=\"2361\" data-end=\"2384\"\u003eNo gas flow to burner\u003c\/li\u003e\n\u003cli data-start=\"2387\" data-end=\"2419\"\u003eIntermittent heating operation\u003c\/li\u003e\n\u003cli data-start=\"2422\" data-end=\"2473\"\u003eConfirmed valve failure during electrical testing\u003c\/li\u003e\n\u003cli data-start=\"2476\" data-end=\"2516\"\u003eInternal sticking or suspected leakage\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"2518\" data-end=\"2603\"\u003eGas valves are safety-critical components and must match your system voltage exactly.\u003c\/p\u003e\n\u003chr data-start=\"2605\" data-end=\"2608\"\u003e\n\u003ch3 data-start=\"2610\" data-end=\"2636\"\u003eProduct Specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli data-start=\"2640\" data-end=\"2676\"\u003e\n\u003cstrong data-start=\"2640\" data-end=\"2657\"\u003eManufacturer:\u003c\/strong\u003e Dometic \/ Atwood\u003c\/li\u003e\n\u003cli data-start=\"2679\" data-end=\"2703\"\u003e\n\u003cstrong data-start=\"2679\" data-end=\"2695\"\u003ePart Number:\u003c\/strong\u003e 31151\u003c\/li\u003e\n\u003cli data-start=\"2706\" data-end=\"2740\"\u003e\n\u003cstrong data-start=\"2706\" data-end=\"2720\"\u003eComponent:\u003c\/strong\u003e Furnace Gas Valve\u003c\/li\u003e\n\u003cli data-start=\"2743\" data-end=\"2768\"\u003e\n\u003cstrong data-start=\"2743\" data-end=\"2755\"\u003eVoltage:\u003c\/strong\u003e 24 Volt AC\u003c\/li\u003e\n\u003cli data-start=\"2771\" data-end=\"2801\"\u003e\n\u003cstrong data-start=\"2771\" data-end=\"2787\"\u003eOutlet Type:\u003c\/strong\u003e Side Outlet\u003c\/li\u003e\n\u003cli data-start=\"2804\" data-end=\"2833\"\u003e\n\u003cstrong data-start=\"2804\" data-end=\"2818\"\u003eFuel Type:\u003c\/strong\u003e Propane (LP)\u003c\/li\u003e\n\u003cli data-start=\"2836\" data-end=\"2875\"\u003e\n\u003cstrong data-start=\"2836\" data-end=\"2849\"\u003eIncludes:\u003c\/strong\u003e Gas valve assembly only\u003c\/li\u003e\n\u003cli data-start=\"2878\" data-end=\"2932\"\u003e\n\u003cstrong data-start=\"2878\" data-end=\"2895\"\u003eAvailability:\u003c\/strong\u003e \u003cem data-start=\"2896\" data-end=\"2932\"\u003eSpecial Order – 7–14 Business Days\u003c\/em\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2934\" data-end=\"2937\"\u003e\n\u003ch2 data-start=\"2939\" data-end=\"2974\"\u003eFrequently Asked Questions (FAQ)\u003c\/h2\u003e\n\u003ch3 data-start=\"2976\" data-end=\"3009\"\u003eQ: Is this a 24-volt valve?\u003c\/h3\u003e\n\u003cp data-start=\"3010\" data-end=\"3072\"\u003eA: Yes. Part 31151 operates on a 24 Volt AC electrical system.\u003c\/p\u003e\n\u003chr data-start=\"3074\" data-end=\"3077\"\u003e\n\u003ch3 data-start=\"3079\" data-end=\"3126\"\u003eQ: How is this different from part 31150?\u003c\/h3\u003e\n\u003cp data-start=\"3127\" data-end=\"3230\"\u003eA: Part 31150 is a 12 Volt DC gas valve. Part 31151 is 24 Volt AC. You must match your furnace voltage.\u003c\/p\u003e\n\u003chr data-start=\"3232\" data-end=\"3235\"\u003e\n\u003ch3 data-start=\"3237\" data-end=\"3275\"\u003eQ: What does “side outlet” mean?\u003c\/h3\u003e\n\u003cp data-start=\"3276\" data-end=\"3389\"\u003eA: The gas outlet exits from the side of the valve body to properly align with compatible burner tube assemblies.\u003c\/p\u003e\n\u003chr data-start=\"3391\" data-end=\"3394\"\u003e\n\u003ch3 data-start=\"3396\" data-end=\"3438\"\u003eQ: Why is this marked Special Order?\u003c\/h3\u003e\n\u003cp data-start=\"3439\" data-end=\"3583\"\u003eA: This part is not typically stocked for immediate shipment and is ordered from the distributor. Estimated shipping time is 7–14 business days.\u003c\/p\u003e\n\u003chr data-start=\"3585\" data-end=\"3588\"\u003e\n\u003ch3 data-start=\"3590\" data-end=\"3619\"\u003eQ: Is this an OEM part?\u003c\/h3\u003e\n\u003cp data-start=\"3620\" data-end=\"3686\"\u003eA: Yes. 31151 is a genuine Dometic \/ Atwood replacement component.\u003c\/p\u003e","brand":"RV Furnace Guys","offers":[{"title":"Default Title","offer_id":47854736179441,"sku":null,"price":64.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0784\/4941\/0289\/files\/GenericDometicLogoforPartswithnoPicture_50f559a1-28a2-4b8b-b91a-ec0c282fe590.jpg?v=1772311063"},{"product_id":"dometic-atwood-33807-furnace-gas-valve-gravity-style","title":"Dometic \/ Atwood 33807 Furnace Gas Valve - Gravity Style - Special Order","description":"\u003ch2 data-start=\"240\" data-end=\"305\"\u003eDometic \/ Atwood 33807 Furnace Gas Valve – Old Style Gravity\u003c\/h2\u003e\n\u003cp data-start=\"306\" data-end=\"392\"\u003e\u003cstrong data-start=\"306\" data-end=\"362\"\u003eSpecial Order Item (7–14 Business Days for Shipping)\u003c\/strong\u003e\u003cbr data-start=\"362\" data-end=\"365\"\u003e\u003cstrong data-start=\"365\" data-end=\"392\"\u003eGenuine OEM Replacement\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"394\" data-end=\"528\"\u003e\u003cstrong data-start=\"394\" data-end=\"410\"\u003ePart Number:\u003c\/strong\u003e 33807\u003cbr data-start=\"416\" data-end=\"419\"\u003e\u003cstrong data-start=\"419\" data-end=\"436\"\u003eProduct Type:\u003c\/strong\u003e Furnace Gas Valve\u003cbr data-start=\"454\" data-end=\"457\"\u003e\u003cstrong data-start=\"457\" data-end=\"473\"\u003eApplication:\u003c\/strong\u003e Atwood HydroFlame® Furnaces (Old Style Gravity Models)\u003c\/p\u003e\n\u003chr data-start=\"530\" data-end=\"533\"\u003e\n\u003ch3 data-start=\"535\" data-end=\"555\"\u003eProduct Overview\u003c\/h3\u003e\n\u003cp data-start=\"557\" data-end=\"843\"\u003eThe \u003cstrong data-start=\"561\" data-end=\"605\"\u003eDometic \/ Atwood 33807 Furnace Gas Valve\u003c\/strong\u003e is a genuine OEM replacement designed for select \u003cstrong data-start=\"655\" data-end=\"700\"\u003eolder Atwood HydroFlame® gravity furnaces\u003c\/strong\u003e. This gas valve regulates propane flow to the burner assembly and is engineered specifically for \u003cstrong data-start=\"798\" data-end=\"842\"\u003eold style gravity furnace configurations\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp data-start=\"845\" data-end=\"1101\"\u003eUnlike modern forced-air furnace systems, gravity furnaces rely on natural convection for air movement. Because of this design difference, the gas valve configuration and control characteristics must match the original gravity-style furnace specifications.\u003c\/p\u003e\n\u003cp data-start=\"1103\" data-end=\"1253\"\u003eReplacing a faulty or leaking gas valve restores safe fuel control and reliable ignition performance in compatible HydroFlame gravity furnace systems.\u003c\/p\u003e\n\u003cp data-start=\"1255\" data-end=\"1353\"\u003e\u003cstrong data-start=\"1255\" data-end=\"1271\"\u003ePlease Note:\u003c\/strong\u003e This is a \u003cem data-start=\"1282\" data-end=\"1297\"\u003eSpecial Order\u003c\/em\u003e item and typically ships within \u003cstrong data-start=\"1330\" data-end=\"1352\"\u003e7–14 business days\u003c\/strong\u003e.\u003c\/p\u003e\n\u003chr data-start=\"1355\" data-end=\"1358\"\u003e\n\u003ch3 data-start=\"1360\" data-end=\"1376\"\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli data-start=\"1380\" data-end=\"1427\"\u003eGenuine OEM Dometic \/ Atwood replacement part\u003c\/li\u003e\n\u003cli data-start=\"1430\" data-end=\"1485\"\u003eDesigned for older HydroFlame® gravity furnace models\u003c\/li\u003e\n\u003cli data-start=\"1488\" data-end=\"1527\"\u003eRegulates propane fuel flow to burner\u003c\/li\u003e\n\u003cli data-start=\"1530\" data-end=\"1573\"\u003eRestores proper ignition and fuel control\u003c\/li\u003e\n\u003cli data-start=\"1576\" data-end=\"1620\"\u003eBuilt to original equipment specifications\u003c\/li\u003e\n\u003cli data-start=\"1623\" data-end=\"1675\"\u003eSpecial Order item (7–14 business days for shipping)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1677\" data-end=\"1680\"\u003e\n\u003ch3 data-start=\"1682\" data-end=\"1709\"\u003eCompatible Applications\u003c\/h3\u003e\n\u003cp data-start=\"1711\" data-end=\"1802\"\u003ePart \u003cstrong data-start=\"1716\" data-end=\"1725\"\u003e33807\u003c\/strong\u003e is compatible with select \u003cstrong data-start=\"1752\" data-end=\"1801\"\u003eAtwood HydroFlame® old style gravity furnaces\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cblockquote data-start=\"1804\" data-end=\"2010\"\u003e\n\u003cp data-start=\"1806\" data-end=\"2010\"\u003eImportant: Always verify your furnace model number and confirm it is an older gravity-style model before ordering. This valve is not intended for modern forced-air 7900, 8500, 8900, or DF series furnaces.\u003c\/p\u003e\n\u003c\/blockquote\u003e\n\u003cp data-start=\"2012\" data-end=\"2154\"\u003eIf you are unsure whether your system is gravity or forced-air, check for a blower motor. Gravity models do not use a powered blower assembly.\u003c\/p\u003e\n\u003chr data-start=\"2156\" data-end=\"2159\"\u003e\n\u003ch3 data-start=\"2161\" data-end=\"2203\"\u003eWhen Should You Replace the Gas Valve?\u003c\/h3\u003e\n\u003cp data-start=\"2205\" data-end=\"2257\"\u003eYou may need to replace the gas valve if you notice:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli data-start=\"2261\" data-end=\"2286\"\u003eFurnace will not ignite\u003c\/li\u003e\n\u003cli data-start=\"2289\" data-end=\"2316\"\u003eNo propane flow to burner\u003c\/li\u003e\n\u003cli data-start=\"2319\" data-end=\"2347\"\u003eIntermittent gas operation\u003c\/li\u003e\n\u003cli data-start=\"2350\" data-end=\"2384\"\u003eConfirmed internal valve failure\u003c\/li\u003e\n\u003cli data-start=\"2387\" data-end=\"2420\"\u003eGas leakage from the valve body\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"2422\" data-end=\"2520\"\u003eGas valves are safety-critical components and must be replaced with the correct OEM configuration.\u003c\/p\u003e\n\u003chr data-start=\"2522\" data-end=\"2525\"\u003e\n\u003ch3 data-start=\"2527\" data-end=\"2553\"\u003eProduct Specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli data-start=\"2557\" data-end=\"2593\"\u003e\n\u003cstrong data-start=\"2557\" data-end=\"2574\"\u003eManufacturer:\u003c\/strong\u003e Dometic \/ Atwood\u003c\/li\u003e\n\u003cli data-start=\"2596\" data-end=\"2620\"\u003e\n\u003cstrong data-start=\"2596\" data-end=\"2612\"\u003ePart Number:\u003c\/strong\u003e 33807\u003c\/li\u003e\n\u003cli data-start=\"2623\" data-end=\"2657\"\u003e\n\u003cstrong data-start=\"2623\" data-end=\"2637\"\u003eComponent:\u003c\/strong\u003e Furnace Gas Valve\u003c\/li\u003e\n\u003cli data-start=\"2660\" data-end=\"2717\"\u003e\n\u003cstrong data-start=\"2660\" data-end=\"2676\"\u003eApplication:\u003c\/strong\u003e HydroFlame® Old Style Gravity Furnaces\u003c\/li\u003e\n\u003cli data-start=\"2720\" data-end=\"2749\"\u003e\n\u003cstrong data-start=\"2720\" data-end=\"2734\"\u003eFuel Type:\u003c\/strong\u003e Propane (LP)\u003c\/li\u003e\n\u003cli data-start=\"2752\" data-end=\"2791\"\u003e\n\u003cstrong data-start=\"2752\" data-end=\"2765\"\u003eIncludes:\u003c\/strong\u003e Gas valve assembly only\u003c\/li\u003e\n\u003cli data-start=\"2794\" data-end=\"2848\"\u003e\n\u003cstrong data-start=\"2794\" data-end=\"2811\"\u003eAvailability:\u003c\/strong\u003e \u003cem data-start=\"2812\" data-end=\"2848\"\u003eSpecial Order – 7–14 Business Days\u003c\/em\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2850\" data-end=\"2853\"\u003e\n\u003ch2 data-start=\"2855\" data-end=\"2890\"\u003eFrequently Asked Questions (FAQ)\u003c\/h2\u003e\n\u003ch3 data-start=\"2892\" data-end=\"2940\"\u003eQ: What is an “old style gravity” furnace?\u003c\/h3\u003e\n\u003cp data-start=\"2941\" data-end=\"3070\"\u003eA: Gravity furnaces do not use a blower motor. Heat rises naturally through convection rather than being forced through ductwork.\u003c\/p\u003e\n\u003chr data-start=\"3072\" data-end=\"3075\"\u003e\n\u003ch3 data-start=\"3077\" data-end=\"3129\"\u003eQ: Will this fit 8500 or 8900 series furnaces?\u003c\/h3\u003e\n\u003cp data-start=\"3130\" data-end=\"3209\"\u003eA: No. This valve is specifically designed for older HydroFlame gravity models.\u003c\/p\u003e\n\u003chr data-start=\"3211\" data-end=\"3214\"\u003e\n\u003ch3 data-start=\"3216\" data-end=\"3258\"\u003eQ: Why is this marked Special Order?\u003c\/h3\u003e\n\u003cp data-start=\"3259\" data-end=\"3423\"\u003eA: This legacy component is not typically stocked for immediate shipment and must be ordered through the distributor. Estimated shipping time is 7–14 business days.\u003c\/p\u003e\n\u003chr data-start=\"3425\" data-end=\"3428\"\u003e\n\u003ch3 data-start=\"3430\" data-end=\"3459\"\u003eQ: Is this an OEM part?\u003c\/h3\u003e\n\u003cp data-start=\"3460\" data-end=\"3531\"\u003eA: Yes. Part 33807 is a genuine Dometic \/ Atwood replacement gas valve.\u003c\/p\u003e","brand":"RV Furnace Guys","offers":[{"title":"Default Title","offer_id":47854736605425,"sku":null,"price":235.49,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0784\/4941\/0289\/files\/GenericDometicLogoforPartswithnoPicture_b1e11cbf-18a4-4b48-801c-6a348c6d3ced.jpg?v=1772311368"},{"product_id":"dometic-atwood-31099-furnace-gas-valve-24-volt-ac-for-afla-series","title":"Dometic \/ Atwood 31099 Furnace Gas Valve – 24 Volt AC for AFLA Series - Special Order","description":"\u003ch2 data-start=\"246\" data-end=\"304\"\u003eDometic \/ Atwood 31099 Furnace Gas Valve – 24 Volt AC\u003c\/h2\u003e\n\u003cp data-start=\"305\" data-end=\"391\"\u003e\u003cstrong data-start=\"305\" data-end=\"361\"\u003eSpecial Order Item (7–14 Business Days for Shipping)\u003c\/strong\u003e\u003cbr data-start=\"361\" data-end=\"364\"\u003e\u003cstrong data-start=\"364\" data-end=\"391\"\u003eGenuine OEM Replacement\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"393\" data-end=\"528\"\u003e\u003cstrong data-start=\"393\" data-end=\"409\"\u003ePart Number:\u003c\/strong\u003e 31099\u003cbr data-start=\"415\" data-end=\"418\"\u003e\u003cstrong data-start=\"418\" data-end=\"435\"\u003eProduct Type:\u003c\/strong\u003e Furnace Gas Valve\u003cbr data-start=\"453\" data-end=\"456\"\u003e\u003cstrong data-start=\"456\" data-end=\"468\"\u003eVoltage:\u003c\/strong\u003e 24 Volt AC\u003cbr data-start=\"479\" data-end=\"482\"\u003e\u003cstrong data-start=\"482\" data-end=\"498\"\u003eApplication:\u003c\/strong\u003e Atwood AFLA Series Furnaces\u003c\/p\u003e\n\u003chr data-start=\"530\" data-end=\"533\"\u003e\n\u003ch3 data-start=\"535\" data-end=\"555\"\u003eProduct Overview\u003c\/h3\u003e\n\u003cp data-start=\"557\" data-end=\"741\"\u003eThe \u003cstrong data-start=\"561\" data-end=\"605\"\u003eDometic \/ Atwood 31099 Furnace Gas Valve\u003c\/strong\u003e is a genuine OEM replacement gas control valve designed for select \u003cstrong data-start=\"673\" data-end=\"704\"\u003eAtwood AFLA series furnaces\u003c\/strong\u003e operating on \u003cstrong data-start=\"718\" data-end=\"740\"\u003e24 Volt AC systems\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp data-start=\"743\" data-end=\"1061\"\u003eThis gas valve regulates propane flow to the burner assembly and works in coordination with the furnace control system to ensure safe ignition and proper heating operation. Matching the correct voltage is critical — installing the proper 24 Volt AC gas valve restores reliable fuel delivery and combustion performance.\u003c\/p\u003e\n\u003cp data-start=\"1063\" data-end=\"1214\"\u003eManufactured to original equipment specifications, Part 31099 ensures proper fitment and dependable operation in compatible HydroFlame furnace systems.\u003c\/p\u003e\n\u003cp data-start=\"1216\" data-end=\"1314\"\u003e\u003cstrong data-start=\"1216\" data-end=\"1232\"\u003ePlease Note:\u003c\/strong\u003e This is a \u003cem data-start=\"1243\" data-end=\"1258\"\u003eSpecial Order\u003c\/em\u003e item and typically ships within \u003cstrong data-start=\"1291\" data-end=\"1313\"\u003e7–14 business days\u003c\/strong\u003e.\u003c\/p\u003e\n\u003chr data-start=\"1316\" data-end=\"1319\"\u003e\n\u003ch3 data-start=\"1321\" data-end=\"1337\"\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli data-start=\"1341\" data-end=\"1388\"\u003eGenuine OEM Dometic \/ Atwood replacement part\u003c\/li\u003e\n\u003cli data-start=\"1391\" data-end=\"1433\"\u003eDesigned for Atwood AFLA series furnaces\u003c\/li\u003e\n\u003cli data-start=\"1436\" data-end=\"1462\"\u003e\u003cstrong data-start=\"1436\" data-end=\"1460\"\u003e24 Volt AC operation\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli data-start=\"1465\" data-end=\"1508\"\u003eRegulates propane flow to burner assembly\u003c\/li\u003e\n\u003cli data-start=\"1511\" data-end=\"1561\"\u003eEnsures reliable ignition and combustion control\u003c\/li\u003e\n\u003cli data-start=\"1564\" data-end=\"1603\"\u003eBuilt to original equipment standards\u003c\/li\u003e\n\u003cli data-start=\"1606\" data-end=\"1658\"\u003eSpecial Order item (7–14 business days for shipping)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1660\" data-end=\"1663\"\u003e\n\u003ch3 data-start=\"1551\" data-end=\"1580\"\u003eCompatible Furnace Models\u003c\/h3\u003e\n\u003cp data-start=\"1582\" data-end=\"1637\"\u003ePart \u003cstrong data-start=\"1587\" data-end=\"1596\"\u003e31099\u003c\/strong\u003e is compatible with the following models:\u003c\/p\u003e\n\u003cp data-start=\"1639\" data-end=\"1654\"\u003e\u003cstrong data-start=\"1639\" data-end=\"1654\"\u003eAFLA Series\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli data-start=\"1657\" data-end=\"1668\"\u003eAFLA35211\u003c\/li\u003e\n\u003cli data-start=\"1671\" data-end=\"1682\"\u003eAFLA40211\u003c\/li\u003e\n\u003cli data-start=\"1685\" data-end=\"1696\"\u003eAFLA35221\u003c\/li\u003e\n\u003cli data-start=\"1699\" data-end=\"1710\"\u003eAFLA40221\u003c\/li\u003e\n\u003cli data-start=\"1713\" data-end=\"1724\"\u003eAFLA35231\u003c\/li\u003e\n\u003cli data-start=\"1727\" data-end=\"1738\"\u003eAFLA40231\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"1740\" data-end=\"1755\"\u003e\u003cstrong data-start=\"1740\" data-end=\"1755\"\u003eDFLA Series\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli data-start=\"1758\" data-end=\"1769\"\u003eDFLA35211\u003c\/li\u003e\n\u003cli data-start=\"1772\" data-end=\"1783\"\u003eDFLA35221\u003c\/li\u003e\n\u003cli data-start=\"1786\" data-end=\"1797\"\u003eDFLA35231\u003c\/li\u003e\n\u003cli data-start=\"1800\" data-end=\"1811\"\u003eDFLA40211\u003c\/li\u003e\n\u003cli data-start=\"1814\" data-end=\"1825\"\u003eDFLA40221\u003c\/li\u003e\n\u003cli data-start=\"1828\" data-end=\"1839\"\u003eDFLA40231\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cblockquote data-start=\"1841\" data-end=\"2035\"\u003e\n\u003cp data-start=\"1843\" data-end=\"2035\"\u003eImportant: Always verify your furnace model number and confirm your system operates on \u003cstrong data-start=\"1930\" data-end=\"1944\"\u003e24 Volt AC\u003c\/strong\u003e before ordering. Installing the incorrect voltage gas valve will prevent proper operation.\u003c\/p\u003e\n\u003c\/blockquote\u003e\n\u003chr data-start=\"2040\" data-end=\"2043\"\u003e\n\u003ch3 data-start=\"2045\" data-end=\"2087\"\u003eWhen Should You Replace the Gas Valve?\u003c\/h3\u003e\n\u003cp data-start=\"2089\" data-end=\"2145\"\u003eYou may need to replace the gas valve if you experience:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli data-start=\"2149\" data-end=\"2190\"\u003eFurnace ignition attempts without flame\u003c\/li\u003e\n\u003cli data-start=\"2193\" data-end=\"2216\"\u003eNo gas flow to burner\u003c\/li\u003e\n\u003cli data-start=\"2219\" data-end=\"2257\"\u003eIntermittent or inconsistent heating\u003c\/li\u003e\n\u003cli data-start=\"2260\" data-end=\"2304\"\u003eConfirmed electrical failure of valve coil\u003c\/li\u003e\n\u003cli data-start=\"2307\" data-end=\"2347\"\u003eInternal sticking or suspected leakage\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"2349\" data-end=\"2450\"\u003eGas valves are critical safety components and must match the voltage and model specification exactly.\u003c\/p\u003e\n\u003chr data-start=\"2452\" data-end=\"2455\"\u003e\n\u003ch3 data-start=\"2457\" data-end=\"2483\"\u003eProduct Specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli data-start=\"2487\" data-end=\"2523\"\u003e\n\u003cstrong data-start=\"2487\" data-end=\"2504\"\u003eManufacturer:\u003c\/strong\u003e Dometic \/ Atwood\u003c\/li\u003e\n\u003cli data-start=\"2526\" data-end=\"2550\"\u003e\n\u003cstrong data-start=\"2526\" data-end=\"2542\"\u003ePart Number:\u003c\/strong\u003e 31099\u003c\/li\u003e\n\u003cli data-start=\"2553\" data-end=\"2587\"\u003e\n\u003cstrong data-start=\"2553\" data-end=\"2567\"\u003eComponent:\u003c\/strong\u003e Furnace Gas Valve\u003c\/li\u003e\n\u003cli data-start=\"2590\" data-end=\"2615\"\u003e\n\u003cstrong data-start=\"2590\" data-end=\"2602\"\u003eVoltage:\u003c\/strong\u003e 24 Volt AC\u003c\/li\u003e\n\u003cli data-start=\"2618\" data-end=\"2647\"\u003e\n\u003cstrong data-start=\"2618\" data-end=\"2640\"\u003eCompatible Series:\u003c\/strong\u003e AFLA\u003c\/li\u003e\n\u003cli data-start=\"2650\" data-end=\"2679\"\u003e\n\u003cstrong data-start=\"2650\" data-end=\"2664\"\u003eFuel Type:\u003c\/strong\u003e Propane (LP)\u003c\/li\u003e\n\u003cli data-start=\"2682\" data-end=\"2721\"\u003e\n\u003cstrong data-start=\"2682\" data-end=\"2695\"\u003eIncludes:\u003c\/strong\u003e Gas valve assembly only\u003c\/li\u003e\n\u003cli data-start=\"2724\" data-end=\"2778\"\u003e\n\u003cstrong data-start=\"2724\" data-end=\"2741\"\u003eAvailability:\u003c\/strong\u003e \u003cem data-start=\"2742\" data-end=\"2778\"\u003eSpecial Order – 7–14 Business Days\u003c\/em\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2780\" data-end=\"2783\"\u003e\n\u003ch2 data-start=\"2785\" data-end=\"2820\"\u003eFrequently Asked Questions (FAQ)\u003c\/h2\u003e\n\u003ch3 data-start=\"2822\" data-end=\"2871\"\u003eQ: What voltage does Part 31099 operate on?\u003c\/h3\u003e\n\u003cp data-start=\"2872\" data-end=\"2913\"\u003eA: It operates on \u003cstrong data-start=\"2890\" data-end=\"2904\"\u003e24 Volt AC\u003c\/strong\u003e systems.\u003c\/p\u003e\n\u003chr data-start=\"2915\" data-end=\"2918\"\u003e\n\u003ch3 data-start=\"2920\" data-end=\"2969\"\u003eQ: Which furnace models use this gas valve?\u003c\/h3\u003e\n\u003cp data-start=\"2970\" data-end=\"3071\"\u003eA: It is compatible with AFLA35211, AFLA40211, AFLA35221, AFLA40221, AFLA35231, and AFLA40231 models.\u003c\/p\u003e\n\u003chr data-start=\"3073\" data-end=\"3076\"\u003e\n\u003ch3 data-start=\"3078\" data-end=\"3126\"\u003eQ: Is this compatible with 12V DC systems?\u003c\/h3\u003e\n\u003cp data-start=\"3127\" data-end=\"3214\"\u003eA: No. This is a 24V AC gas valve. Always confirm your furnace voltage before ordering.\u003c\/p\u003e\n\u003chr data-start=\"3216\" data-end=\"3219\"\u003e\n\u003ch3 data-start=\"3221\" data-end=\"3263\"\u003eQ: Why is this marked Special Order?\u003c\/h3\u003e\n\u003cp data-start=\"3264\" data-end=\"3418\"\u003eA: This component is not typically stocked for immediate shipment and must be ordered from the distributor. Estimated delivery time is 7–14 business days.\u003c\/p\u003e\n\u003chr data-start=\"3420\" data-end=\"3423\"\u003e\n\u003ch3 data-start=\"3425\" data-end=\"3454\"\u003eQ: Is this an OEM part?\u003c\/h3\u003e\n\u003cp data-start=\"3455\" data-end=\"3526\"\u003eA: Yes. Part 31099 is a genuine Dometic \/ Atwood replacement component.\u003c\/p\u003e","brand":"RV Furnace Guys","offers":[{"title":"Default Title","offer_id":47854737129713,"sku":null,"price":159.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0784\/4941\/0289\/files\/31099.jpg?v=1772311734"},{"product_id":"dometic-atwood-32172-furnace-gasket-dsi-ignition-models","title":"Dometic \/ Atwood 32172 Furnace Gasket – DSI Ignition Models","description":"\u003ch2 data-start=\"166\" data-end=\"230\"\u003eDometic \/ Atwood 32172 Furnace Gasket – DSI Ignition Models\u003c\/h2\u003e\n\u003cp data-start=\"231\" data-end=\"258\"\u003e\u003cstrong data-start=\"231\" data-end=\"258\"\u003eGenuine OEM Replacement\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"260\" data-end=\"372\"\u003e\u003cstrong data-start=\"260\" data-end=\"276\"\u003ePart Number:\u003c\/strong\u003e 32172\u003cbr data-start=\"282\" data-end=\"285\"\u003e\u003cstrong data-start=\"285\" data-end=\"302\"\u003eProduct Type:\u003c\/strong\u003e Furnace Gasket\u003cbr data-start=\"317\" data-end=\"320\"\u003e\u003cstrong data-start=\"320\" data-end=\"336\"\u003eApplication:\u003c\/strong\u003e Atwood Furnaces with DSI Ignition\u003c\/p\u003e\n\u003chr data-start=\"374\" data-end=\"377\"\u003e\n\u003ch3 data-start=\"379\" data-end=\"399\"\u003eProduct Overview\u003c\/h3\u003e\n\u003cp data-start=\"401\" data-end=\"575\"\u003eThe \u003cstrong data-start=\"405\" data-end=\"446\"\u003eDometic \/ Atwood 32172 Furnace Gasket\u003c\/strong\u003e is a genuine OEM replacement gasket designed for use with \u003cstrong data-start=\"505\" data-end=\"566\"\u003eAtwood furnaces equipped with DSI (Direct Spark Ignition)\u003c\/strong\u003e systems.\u003c\/p\u003e\n\u003cp data-start=\"577\" data-end=\"863\"\u003eThis gasket provides a secure seal between key furnace components, helping maintain proper combustion airflow and preventing air leakage within the burner chamber area. Maintaining an intact seal is critical for efficient ignition, correct flame performance, and safe furnace operation.\u003c\/p\u003e\n\u003cp data-start=\"865\" data-end=\"1058\"\u003eOver time, gaskets can deteriorate due to heat cycling and vibration. Replacing a worn or damaged gasket with OEM Part 32172 restores proper sealing and supports consistent furnace performance.\u003c\/p\u003e\n\u003cp data-start=\"1060\" data-end=\"1206\"\u003eManufactured to original equipment specifications, this gasket ensures correct fitment and durability in high-temperature RV heating applications.\u003c\/p\u003e\n\u003chr data-start=\"1208\" data-end=\"1211\"\u003e\n\u003ch3 data-start=\"1213\" data-end=\"1229\"\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli data-start=\"1233\" data-end=\"1280\"\u003eGenuine OEM Dometic \/ Atwood replacement part\u003c\/li\u003e\n\u003cli data-start=\"1283\" data-end=\"1331\"\u003eDesigned for Atwood furnaces with DSI ignition\u003c\/li\u003e\n\u003cli data-start=\"1334\" data-end=\"1376\"\u003eMaintains proper combustion chamber seal\u003c\/li\u003e\n\u003cli data-start=\"1379\" data-end=\"1432\"\u003ePrevents air leakage affecting ignition performance\u003c\/li\u003e\n\u003cli data-start=\"1435\" data-end=\"1464\"\u003eHeat-resistant construction\u003c\/li\u003e\n\u003cli data-start=\"1467\" data-end=\"1513\"\u003eManufactured to original equipment standards\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1515\" data-end=\"1518\"\u003e\n\u003ch3 data-start=\"1520\" data-end=\"1547\"\u003eCompatible Applications\u003c\/h3\u003e\n\u003cp data-start=\"1549\" data-end=\"1653\"\u003ePart \u003cstrong data-start=\"1554\" data-end=\"1563\"\u003e32172\u003c\/strong\u003e is compatible with \u003cstrong data-start=\"1583\" data-end=\"1652\"\u003eAtwood furnaces equipped with DSI (Direct Spark Ignition) systems\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cblockquote data-start=\"1655\" data-end=\"1844\"\u003e\n\u003cp data-start=\"1657\" data-end=\"1844\"\u003eImportant: Always verify your furnace ignition type before ordering. This gasket is designed specifically for DSI-equipped models and may not fit standing pilot or gravity-style furnaces.\u003c\/p\u003e\n\u003c\/blockquote\u003e\n\u003cp data-start=\"1846\" data-end=\"1888\"\u003eCommon DSI-equipped series include select:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli data-start=\"1891\" data-end=\"1902\"\u003e79 Series\u003c\/li\u003e\n\u003cli data-start=\"1905\" data-end=\"1916\"\u003e80 Series\u003c\/li\u003e\n\u003cli data-start=\"1919\" data-end=\"1930\"\u003e85 Series\u003c\/li\u003e\n\u003cli data-start=\"1933\" data-end=\"1944\"\u003e89 Series\u003c\/li\u003e\n\u003cli data-start=\"1947\" data-end=\"1965\"\u003eDF Series models\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"1967\" data-end=\"2038\"\u003eAlways confirm your exact furnace model number to ensure compatibility.\u003c\/p\u003e\n\u003chr data-start=\"2040\" data-end=\"2043\"\u003e\n\u003ch3 data-start=\"2045\" data-end=\"2084\"\u003eWhen Should You Replace the Gasket?\u003c\/h3\u003e\n\u003cp data-start=\"2086\" data-end=\"2135\"\u003eYou may need to replace the gasket if you notice:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli data-start=\"2139\" data-end=\"2166\"\u003eRepeated ignition failure\u003c\/li\u003e\n\u003cli data-start=\"2169\" data-end=\"2201\"\u003eImproper flame characteristics\u003c\/li\u003e\n\u003cli data-start=\"2204\" data-end=\"2240\"\u003eAir leakage around burner assembly\u003c\/li\u003e\n\u003cli data-start=\"2243\" data-end=\"2283\"\u003eVisible cracking or compression damage\u003c\/li\u003e\n\u003cli data-start=\"2286\" data-end=\"2331\"\u003eFurnace service requiring component removal\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"2333\" data-end=\"2426\"\u003eReplacing the gasket during routine burner service is recommended to maintain proper sealing.\u003c\/p\u003e\n\u003chr data-start=\"2428\" data-end=\"2431\"\u003e\n\u003ch3 data-start=\"2433\" data-end=\"2459\"\u003eProduct Specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli data-start=\"2463\" data-end=\"2499\"\u003e\n\u003cstrong data-start=\"2463\" data-end=\"2480\"\u003eManufacturer:\u003c\/strong\u003e Dometic \/ Atwood\u003c\/li\u003e\n\u003cli data-start=\"2502\" data-end=\"2526\"\u003e\n\u003cstrong data-start=\"2502\" data-end=\"2518\"\u003ePart Number:\u003c\/strong\u003e 32172\u003c\/li\u003e\n\u003cli data-start=\"2529\" data-end=\"2560\"\u003e\n\u003cstrong data-start=\"2529\" data-end=\"2543\"\u003eComponent:\u003c\/strong\u003e Furnace Gasket\u003c\/li\u003e\n\u003cli data-start=\"2563\" data-end=\"2610\"\u003e\n\u003cstrong data-start=\"2563\" data-end=\"2579\"\u003eApplication:\u003c\/strong\u003e Atwood DSI Ignition Furnaces\u003c\/li\u003e\n\u003cli data-start=\"2613\" data-end=\"2659\"\u003e\n\u003cstrong data-start=\"2613\" data-end=\"2626\"\u003eMaterial:\u003c\/strong\u003e Heat-resistant gasket material\u003c\/li\u003e\n\u003cli data-start=\"2662\" data-end=\"2689\"\u003e\n\u003cstrong data-start=\"2662\" data-end=\"2675\"\u003eIncludes:\u003c\/strong\u003e Gasket only\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2691\" data-end=\"2694\"\u003e\n\u003ch2 data-start=\"2696\" data-end=\"2731\"\u003eFrequently Asked Questions (FAQ)\u003c\/h2\u003e\n\u003ch3 data-start=\"2733\" data-end=\"2761\"\u003eQ: What does DSI mean?\u003c\/h3\u003e\n\u003cp data-start=\"2762\" data-end=\"2898\"\u003eA: DSI stands for Direct Spark Ignition, meaning the furnace ignites the burner electronically rather than using a standing pilot light.\u003c\/p\u003e\n\u003chr data-start=\"2900\" data-end=\"2903\"\u003e\n\u003ch3 data-start=\"2905\" data-end=\"2955\"\u003eQ: Will this fit pilot-light style furnaces?\u003c\/h3\u003e\n\u003cp data-start=\"2956\" data-end=\"3024\"\u003eA: No. This gasket is designed specifically for DSI ignition models.\u003c\/p\u003e\n\u003chr data-start=\"3026\" data-end=\"3029\"\u003e\n\u003ch3 data-start=\"3031\" data-end=\"3060\"\u003eQ: Is this an OEM part?\u003c\/h3\u003e\n\u003cp data-start=\"3061\" data-end=\"3127\"\u003eA: Yes. 32172 is a genuine Dometic \/ Atwood replacement component.\u003c\/p\u003e\n\u003chr data-start=\"3129\" data-end=\"3132\"\u003e\n\u003ch3 data-start=\"3134\" data-end=\"3182\"\u003eQ: When should I replace a furnace gasket?\u003c\/h3\u003e\n\u003cp data-start=\"3183\" data-end=\"3308\"\u003eA: Gaskets should be replaced whenever removed during service or if they show signs of wear, cracking, or heat deterioration.\u003c\/p\u003e","brand":"RV Furnace Guys","offers":[{"title":"Default Title","offer_id":47854737883377,"sku":null,"price":8.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0784\/4941\/0289\/files\/32172.png?v=1772312027"},{"product_id":"atwood-dometic-31077-furnace-burner-orifice-49lp","title":"Atwood \/ Dometic 31077 Furnace Burner Orifice – #49LP - Special Order","description":"\u003ch1 data-section-id=\"1chydty\" data-start=\"154\" data-end=\"225\"\u003eAtwood \/ Dometic 31077 Furnace Burner Orifice – #49LP (Special Order)\u003c\/h1\u003e\n\u003ch2 data-section-id=\"1idoleh\" data-start=\"227\" data-end=\"283\"\u003eAtwood \/ Dometic 31077 Furnace Burner Orifice (#49LP)\u003c\/h2\u003e\n\u003cp data-start=\"285\" data-end=\"573\"\u003eThe \u003cstrong data-start=\"289\" data-end=\"338\"\u003eAtwood \/ Dometic 31077 Furnace Burner Orifice\u003c\/strong\u003e is a precision gas metering component designed for Atwood RV furnaces. This \u003cstrong data-start=\"415\" data-end=\"440\"\u003e#49LP propane orifice\u003c\/strong\u003e regulates the amount of LP gas flowing into the furnace burner assembly, ensuring proper combustion and efficient furnace operation.\u003c\/p\u003e\n\u003cp data-start=\"575\" data-end=\"779\"\u003eIf your RV furnace is experiencing \u003cstrong data-start=\"610\" data-end=\"691\"\u003eweak flames, ignition problems, delayed ignition, or poor heating performance\u003c\/strong\u003e, the burner orifice may be \u003cstrong data-start=\"719\" data-end=\"748\"\u003eclogged, damaged, or worn\u003c\/strong\u003e, making replacement necessary.\u003c\/p\u003e\n\u003cp data-start=\"781\" data-end=\"955\"\u003eThis part is a \u003cstrong data-start=\"796\" data-end=\"853\"\u003edirect replacement for Atwood furnace burner orifices\u003c\/strong\u003e used in many models and restores the correct fuel-to-air mixture required for safe furnace operation.\u003c\/p\u003e\n\u003cp data-start=\"957\" data-end=\"1003\"\u003e⚠️ \u003cstrong data-start=\"960\" data-end=\"1003\"\u003eSpecial Order Item – Ships in 7–14 days\u003c\/strong\u003e\u003c\/p\u003e\n\u003chr data-start=\"1005\" data-end=\"1008\"\u003e\n\u003ch2 data-section-id=\"1d7mrtu\" data-start=\"1010\" data-end=\"1021\"\u003eFeatures\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli data-start=\"1025\" data-end=\"1070\"\u003eGenuine \u003cstrong data-start=\"1033\" data-end=\"1070\"\u003eAtwood \/ Dometic replacement part\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1073\" data-end=\"1105\"\u003e\u003cstrong data-start=\"1073\" data-end=\"1105\"\u003e#49LP propane burner orifice\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli data-start=\"1108\" data-end=\"1161\"\u003eEnsures proper \u003cstrong data-start=\"1123\" data-end=\"1161\"\u003eLP gas flow to the burner assembly\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1164\" data-end=\"1224\"\u003eHelps restore \u003cstrong data-start=\"1178\" data-end=\"1224\"\u003ecorrect flame size and heating performance\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1227\" data-end=\"1269\"\u003ePrecision-machined for reliable combustion\u003c\/li\u003e\n\u003cli data-start=\"1272\" data-end=\"1314\"\u003eDesigned for \u003cstrong data-start=\"1285\" data-end=\"1314\"\u003eAtwood RV furnace systems\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1316\" data-end=\"1319\"\u003e\n\u003ch2 data-section-id=\"8sk4io\" data-start=\"1321\" data-end=\"1366\"\u003eCommon Symptoms of a Faulty Burner Orifice\u003c\/h2\u003e\n\u003cp data-start=\"1368\" data-end=\"1448\"\u003eYou may need to replace the burner orifice if your furnace shows these symptoms:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli data-start=\"1452\" data-end=\"1487\"\u003eWeak or inconsistent burner flame\u003c\/li\u003e\n\u003cli data-start=\"1490\" data-end=\"1532\"\u003eFurnace ignites but produces little heat\u003c\/li\u003e\n\u003cli data-start=\"1535\" data-end=\"1576\"\u003eDelayed ignition or burner flame issues\u003c\/li\u003e\n\u003cli data-start=\"1579\" data-end=\"1622\"\u003eFurnace shuts down after ignition attempt\u003c\/li\u003e\n\u003cli data-start=\"1625\" data-end=\"1669\"\u003ePropane burner not receiving proper gas flow\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"1671\" data-end=\"1792\"\u003eIn many cases, the orifice becomes \u003cstrong data-start=\"1706\" data-end=\"1769\"\u003eclogged with debris, oil residue from propane, or corrosion\u003c\/strong\u003e, restricting gas flow.\u003c\/p\u003e\n\u003ch2 data-section-id=\"1hryhf7\" data-start=\"2760\" data-end=\"2766\"\u003eFAQ\u003c\/h2\u003e\n\u003ch3 data-section-id=\"1m4mbud\" data-start=\"2768\" data-end=\"2812\"\u003eWhat does the furnace burner orifice do?\u003c\/h3\u003e\n\u003cp data-start=\"2813\" data-end=\"2976\"\u003eThe burner orifice regulates the \u003cstrong data-start=\"2846\" data-end=\"2896\"\u003eamount of propane entering the burner assembly\u003c\/strong\u003e, creating the correct air-fuel mixture needed for efficient furnace combustion.\u003c\/p\u003e\n\u003ch3 data-section-id=\"xb3y1j\" data-start=\"2978\" data-end=\"3034\"\u003eCan a burner orifice be cleaned instead of replaced?\u003c\/h3\u003e\n\u003cp data-start=\"3035\" data-end=\"3183\"\u003eSometimes minor debris can be cleaned, but \u003cstrong data-start=\"3078\" data-end=\"3110\"\u003eorifices are precision sized\u003c\/strong\u003e. If they are damaged, corroded, or enlarged, replacement is recommended.\u003c\/p\u003e\n\u003ch3 data-section-id=\"f3uom2\" data-start=\"3185\" data-end=\"3212\"\u003eWhat does “#49LP” mean?\u003c\/h3\u003e\n\u003cp data-start=\"3213\" data-end=\"3334\"\u003eThe \u003cstrong data-start=\"3217\" data-end=\"3224\"\u003e#49\u003c\/strong\u003e refers to the \u003cstrong data-start=\"3239\" data-end=\"3261\"\u003eorifice drill size\u003c\/strong\u003e, which determines the precise amount of propane delivered to the burner.\u003c\/p\u003e\n\u003ch3 data-section-id=\"6uy0l7\" data-start=\"3336\" data-end=\"3397\"\u003eHow do I know if my RV furnace burner orifice is clogged?\u003c\/h3\u003e\n\u003cp data-start=\"3398\" data-end=\"3487\"\u003eSigns include \u003cstrong data-start=\"3412\" data-end=\"3486\"\u003eweak flames, delayed ignition, furnace cycling, or poor heating output\u003c\/strong\u003e.\u003c\/p\u003e","brand":"RV Furnace Guys","offers":[{"title":"Default Title","offer_id":47889210081521,"sku":null,"price":11.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0784\/4941\/0289\/files\/31077Orifice49.jpg?v=1773187753"},{"product_id":"atwood-dometic-furnace-burner-orifice-51lp-part-31080","title":"Atwood \/ Dometic Furnace Burner Orifice – #51LP - Part #31080 - Special Order","description":"\u003ch1 data-section-id=\"b5flod\" data-start=\"0\" data-end=\"65\"\u003eAtwood \/ Dometic Furnace Burner Orifice – #51LP (Special Order)\u003c\/h1\u003e\n\u003ch2 data-section-id=\"hcrj5y\" data-start=\"67\" data-end=\"123\"\u003eFurnace Burner Orifice – #51LP for Atwood RV Furnaces\u003c\/h2\u003e\n\u003cp data-start=\"125\" data-end=\"458\"\u003eThe \u003cstrong data-start=\"129\" data-end=\"178\"\u003eAtwood \/ Dometic #51LP Furnace Burner Orifice\u003c\/strong\u003e is a precision gas metering component designed for use in \u003cstrong data-start=\"237\" data-end=\"276\"\u003eAtwood RV furnace burner assemblies\u003c\/strong\u003e. This propane orifice controls the exact amount of LP gas entering the burner, ensuring the proper air-fuel mixture needed for efficient ignition and consistent heating performance.\u003c\/p\u003e\n\u003cp data-start=\"460\" data-end=\"661\"\u003eIf your RV furnace is experiencing \u003cstrong data-start=\"495\" data-end=\"579\"\u003eweak flames, inconsistent heating, delayed ignition, or burner ignition failures\u003c\/strong\u003e, the burner orifice may be \u003cstrong data-start=\"607\" data-end=\"636\"\u003eclogged, damaged, or worn\u003c\/strong\u003e and require replacement.\u003c\/p\u003e\n\u003cp data-start=\"663\" data-end=\"767\"\u003eReplacing the orifice restores the proper propane flow required for safe and reliable furnace operation.\u003c\/p\u003e\n\u003cp data-start=\"769\" data-end=\"815\"\u003e⚠️ \u003cstrong data-start=\"772\" data-end=\"815\"\u003eSpecial Order Item – Ships in 7–14 days\u003c\/strong\u003e\u003c\/p\u003e\n\u003chr data-start=\"817\" data-end=\"820\"\u003e\n\u003ch2 data-section-id=\"1d7mrtu\" data-start=\"822\" data-end=\"833\"\u003eFeatures\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli data-start=\"837\" data-end=\"890\"\u003eReplacement \u003cstrong data-start=\"849\" data-end=\"890\"\u003eburner orifice for Atwood RV furnaces\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"893\" data-end=\"923\"\u003e\u003cstrong data-start=\"893\" data-end=\"923\"\u003e#51LP propane orifice size\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli data-start=\"926\" data-end=\"971\"\u003ePrecision metering for proper \u003cstrong data-start=\"956\" data-end=\"971\"\u003eLP gas flow\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"974\" data-end=\"1034\"\u003eHelps restore \u003cstrong data-start=\"988\" data-end=\"1034\"\u003ecorrect flame size and furnace performance\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1037\" data-end=\"1063\"\u003eDurable brass construction\u003c\/li\u003e\n\u003cli data-start=\"1066\" data-end=\"1122\"\u003eDesigned for \u003cstrong data-start=\"1079\" data-end=\"1122\"\u003eAtwood \/ Dometic furnace burner systems\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1124\" data-end=\"1127\"\u003e\n\u003ch2 data-section-id=\"8sk4io\" data-start=\"1129\" data-end=\"1174\"\u003eCommon Symptoms of a Faulty Burner Orifice\u003c\/h2\u003e\n\u003cp data-start=\"1176\" data-end=\"1236\"\u003eYour RV furnace may need a new burner orifice if you notice:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli data-start=\"1240\" data-end=\"1271\"\u003eWeak or unstable burner flame\u003c\/li\u003e\n\u003cli data-start=\"1274\" data-end=\"1316\"\u003eFurnace ignites but produces little heat\u003c\/li\u003e\n\u003cli data-start=\"1319\" data-end=\"1354\"\u003eDelayed ignition or flame rollout\u003c\/li\u003e\n\u003cli data-start=\"1357\" data-end=\"1393\"\u003eFurnace repeatedly tries to ignite\u003c\/li\u003e\n\u003cli data-start=\"1396\" data-end=\"1435\"\u003eInconsistent propane flow to the burner\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"1437\" data-end=\"1591\"\u003eOver time, burner orifices can become \u003cstrong data-start=\"1475\" data-end=\"1537\"\u003erestricted by debris, oil residue in propane, or corrosion\u003c\/strong\u003e, which reduces the amount of gas reaching the burner.\u003c\/p\u003e\n\u003ch2 data-section-id=\"1hryhf7\" data-start=\"2600\" data-end=\"2606\"\u003eFAQ\u003c\/h2\u003e\n\u003ch3 data-section-id=\"1m4mbud\" data-start=\"2608\" data-end=\"2652\"\u003eWhat does the furnace burner orifice do?\u003c\/h3\u003e\n\u003cp data-start=\"2653\" data-end=\"2804\"\u003eThe burner orifice regulates the \u003cstrong data-start=\"2686\" data-end=\"2735\"\u003eamount of propane entering the furnace burner\u003c\/strong\u003e, creating the correct mixture of air and fuel needed for combustion.\u003c\/p\u003e\n\u003ch3 data-section-id=\"ozwhn7\" data-start=\"2806\" data-end=\"2833\"\u003eWhat does “#51LP” mean?\u003c\/h3\u003e\n\u003cp data-start=\"2834\" data-end=\"2963\"\u003eThe \u003cstrong data-start=\"2838\" data-end=\"2845\"\u003e#51\u003c\/strong\u003e refers to the precision \u003cstrong data-start=\"2870\" data-end=\"2907\"\u003edrill size of the orifice opening\u003c\/strong\u003e, which determines how much propane flows to the burner.\u003c\/p\u003e\n\u003ch3 data-section-id=\"yywmb0\" data-start=\"2965\" data-end=\"3023\"\u003eCan a clogged orifice cause furnace ignition problems?\u003c\/h3\u003e\n\u003cp data-start=\"3024\" data-end=\"3150\"\u003eYes. If the orifice is partially blocked, the furnace may produce \u003cstrong data-start=\"3090\" data-end=\"3149\"\u003eweak flames, delayed ignition, or fail to heat properly\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3 data-section-id=\"11lt0ux\" data-start=\"3152\" data-end=\"3185\"\u003eCan I clean a burner orifice?\u003c\/h3\u003e\n\u003cp data-start=\"3186\" data-end=\"3334\"\u003eMinor debris may sometimes be removed, but since orifices are \u003cstrong data-start=\"3248\" data-end=\"3267\"\u003eprecision sized\u003c\/strong\u003e, replacement is often recommended if performance problems persist.\u003c\/p\u003e","brand":"RV Furnace Guys","offers":[{"title":"Default Title","offer_id":47889214374129,"sku":null,"price":11.19,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0784\/4941\/0289\/files\/3108051orifice.webp?v=1773187991"},{"product_id":"dometic-atwood-31081-furnace-burner-orifice-52lp","title":"Dometic \/ Atwood 31081 Furnace Burner Orifice – #52LP - Special Order","description":"\u003ch1 data-section-id=\"1z15ds\" data-start=\"0\" data-end=\"89\"\u003eDometic \/ Atwood 31081 Furnace Burner Orifice – #52LP (AFMD30 Furnaces) – Special Order\u003c\/h1\u003e\n\u003ch2 data-section-id=\"1qsgbil\" data-start=\"91\" data-end=\"152\"\u003eDometic Atwood 31081 Burner Orifice for AFMD30 RV Furnaces\u003c\/h2\u003e\n\u003cp data-start=\"154\" data-end=\"486\"\u003eThe \u003cstrong data-start=\"158\" data-end=\"215\"\u003eDometic \/ Atwood 31081 Furnace Burner Orifice (#52LP)\u003c\/strong\u003e is a precision propane metering component designed specifically for \u003cstrong data-start=\"284\" data-end=\"319\"\u003eAtwood AFMD30 model RV furnaces\u003c\/strong\u003e. This orifice regulates the exact amount of LP gas delivered to the burner assembly, ensuring proper combustion, reliable ignition, and efficient heating performance.\u003c\/p\u003e\n\u003cp data-start=\"488\" data-end=\"698\"\u003eIf your AFMD30 furnace is experiencing \u003cstrong data-start=\"527\" data-end=\"616\"\u003eweak flames, ignition delays, poor heating output, or inconsistent burner performance\u003c\/strong\u003e, the burner orifice may be \u003cstrong data-start=\"644\" data-end=\"673\"\u003eclogged, worn, or damaged\u003c\/strong\u003e and require replacement.\u003c\/p\u003e\n\u003cp data-start=\"700\" data-end=\"850\"\u003eInstalling a new burner orifice restores the correct propane flow and helps maintain the proper air-to-fuel mixture needed for safe furnace operation.\u003c\/p\u003e\n\u003cp data-start=\"852\" data-end=\"898\"\u003e⚠️ \u003cstrong data-start=\"855\" data-end=\"898\"\u003eSpecial Order Item – Ships in 7–14 days\u003c\/strong\u003e\u003c\/p\u003e\n\u003chr data-start=\"900\" data-end=\"903\"\u003e\n\u003ch2 data-section-id=\"1d7mrtu\" data-start=\"905\" data-end=\"916\"\u003eFeatures\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli data-start=\"920\" data-end=\"965\"\u003eGenuine \u003cstrong data-start=\"928\" data-end=\"965\"\u003eDometic \/ Atwood replacement part\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"968\" data-end=\"1010\"\u003eDesigned for \u003cstrong data-start=\"981\" data-end=\"1010\"\u003eAtwood AFMD30 RV furnaces\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1013\" data-end=\"1045\"\u003e\u003cstrong data-start=\"1013\" data-end=\"1045\"\u003e#52LP propane burner orifice\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli data-start=\"1048\" data-end=\"1100\"\u003ePrecision gas metering for proper burner performance\u003c\/li\u003e\n\u003cli data-start=\"1103\" data-end=\"1162\"\u003eHelps restore \u003cstrong data-start=\"1117\" data-end=\"1162\"\u003ecorrect flame size and heating efficiency\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1165\" data-end=\"1191\"\u003eDurable brass construction\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1193\" data-end=\"1196\"\u003e\n\u003ch2 data-section-id=\"18dvupj\" data-start=\"1198\" data-end=\"1226\"\u003eCompatible Furnace Models\u003c\/h2\u003e\n\u003cp data-start=\"1228\" data-end=\"1273\"\u003eThis burner orifice is designed for use with:\u003c\/p\u003e\n\u003cul data-start=\"1275\" data-end=\"1306\"\u003e\n\u003cli data-section-id=\"1142g0s\" data-start=\"1275\" data-end=\"1306\"\u003e\n\u003cp data-start=\"1277\" data-end=\"1306\"\u003e\u003cstrong data-start=\"1277\" data-end=\"1306\"\u003eAtwood AFMD30 RV Furnaces\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"1308\" data-end=\"1381\"\u003eAlways verify your furnace model before ordering to ensure compatibility.\u003c\/p\u003e\n\u003chr data-start=\"1383\" data-end=\"1386\"\u003e\n\u003ch2 data-section-id=\"8sk4io\" data-start=\"1388\" data-end=\"1433\"\u003eCommon Symptoms of a Faulty Burner Orifice\u003c\/h2\u003e\n\u003cp data-start=\"1435\" data-end=\"1533\"\u003eYou may need to replace the burner orifice if your RV furnace shows any of the following symptoms:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli data-start=\"1537\" data-end=\"1568\"\u003eWeak or unstable burner flame\u003c\/li\u003e\n\u003cli data-start=\"1571\" data-end=\"1613\"\u003eFurnace ignites but produces little heat\u003c\/li\u003e\n\u003cli data-start=\"1616\" data-end=\"1641\"\u003eDelayed burner ignition\u003c\/li\u003e\n\u003cli data-start=\"1644\" data-end=\"1683\"\u003eFurnace repeatedly attempts to ignite\u003c\/li\u003e\n\u003cli data-start=\"1686\" data-end=\"1726\"\u003ePoor propane flow to the burner assembly\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"1728\" data-end=\"1880\"\u003eOver time, burner orifices can become \u003cstrong data-start=\"1766\" data-end=\"1826\"\u003erestricted by debris, corrosion, or residue from propane\u003c\/strong\u003e, reducing gas flow and affecting furnace performance.\u003c\/p\u003e\n\u003chr data-start=\"2884\" data-end=\"2887\"\u003e\n\u003ch2 data-section-id=\"1hryhf7\" data-start=\"2889\" data-end=\"2895\"\u003eFAQ\u003c\/h2\u003e\n\u003ch3 data-section-id=\"1m4mbud\" data-start=\"2897\" data-end=\"2941\"\u003eWhat does the furnace burner orifice do?\u003c\/h3\u003e\n\u003cp data-start=\"2942\" data-end=\"3098\"\u003eThe burner orifice controls the \u003cstrong data-start=\"2974\" data-end=\"3024\"\u003eamount of propane entering the burner assembly\u003c\/strong\u003e, ensuring the correct air-fuel mixture for safe and efficient combustion.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1ymni28\" data-start=\"3100\" data-end=\"3127\"\u003eWhat does “#52LP” mean?\u003c\/h3\u003e\n\u003cp data-start=\"3128\" data-end=\"3266\"\u003eThe \u003cstrong data-start=\"3132\" data-end=\"3139\"\u003e#52\u003c\/strong\u003e refers to the precision \u003cstrong data-start=\"3164\" data-end=\"3201\"\u003edrill size of the orifice opening\u003c\/strong\u003e, which determines the amount of propane delivered to the burner.\u003c\/p\u003e\n\u003ch3 data-section-id=\"yywmb0\" data-start=\"3268\" data-end=\"3326\"\u003eCan a clogged orifice cause furnace ignition problems?\u003c\/h3\u003e\n\u003cp data-start=\"3327\" data-end=\"3425\"\u003eYes. A restricted orifice can cause \u003cstrong data-start=\"3363\" data-end=\"3424\"\u003eweak flames, ignition delays, or poor heating performance\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3 data-section-id=\"184i58u\" data-start=\"3427\" data-end=\"3465\"\u003eCan the burner orifice be cleaned?\u003c\/h3\u003e\n\u003cp data-start=\"3466\" data-end=\"3623\"\u003eSometimes minor debris can be removed, but since the orifice is \u003cstrong data-start=\"3530\" data-end=\"3549\"\u003eprecision sized\u003c\/strong\u003e, replacement is often recommended if furnace performance issues continue.\u003c\/p\u003e","brand":"RV Furnace Guys","offers":[{"title":"Default Title","offer_id":47892532986097,"sku":null,"price":11.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0784\/4941\/0289\/files\/31081.webp?v=1773263516"},{"product_id":"dometic™-atwood-38603-furnace-valve-coil-24v-ac-fits-8900-iii-8900iii-ld-series-rv-furnaces","title":"Dometic™ \/ Atwood 38603 Furnace Valve Coil – 24V AC – Fits 8900 III \u0026 8900III LD Series RV Furnaces","description":"\u003ch1 data-section-id=\"1s3o9yv\" data-start=\"90\" data-end=\"191\"\u003eDometic™ \/ Atwood 38603 Furnace Valve Coil – 24V AC – Fits 8900 III \u0026amp; 8900III LD Series RV Furnaces\u003c\/h1\u003e\n\u003ch2 data-section-id=\"1p927wt\" data-start=\"193\" data-end=\"212\"\u003eProduct Overview\u003c\/h2\u003e\n\u003cp data-start=\"213\" data-end=\"522\"\u003eThe \u003cstrong data-start=\"217\" data-end=\"262\"\u003eDometic \/ Atwood 38603 Furnace Valve Coil\u003c\/strong\u003e is a replacement electrical coil designed for use with \u003cstrong data-start=\"318\" data-end=\"371\"\u003eAtwood 8900 III and 8900III LD Series RV furnaces\u003c\/strong\u003e. This \u003cstrong data-start=\"378\" data-end=\"403\"\u003e24-volt AC valve coil\u003c\/strong\u003e activates the gas valve when the furnace calls for heat, allowing propane to flow to the burner assembly for ignition.\u003c\/p\u003e\n\u003cp data-start=\"524\" data-end=\"762\"\u003eIf your furnace blower runs but \u003cstrong data-start=\"556\" data-end=\"589\"\u003eno gas is reaching the burner\u003c\/strong\u003e, a failed valve coil may be preventing the gas valve from opening. Replacing the coil with the \u003cstrong data-start=\"685\" data-end=\"701\"\u003eAtwood 38603\u003c\/strong\u003e can restore proper furnace ignition and heating performance.\u003c\/p\u003e\n\u003cp data-start=\"764\" data-end=\"892\"\u003eThis replacement coil is designed for \u003cstrong data-start=\"802\" data-end=\"842\"\u003eside outlet gas valve configurations\u003c\/strong\u003e used on select Atwood Hydro Flame furnace models.\u003c\/p\u003e\n\u003chr data-start=\"894\" data-end=\"897\"\u003e\n\u003ch2 data-section-id=\"1ma7m6t\" data-start=\"899\" data-end=\"914\"\u003eKey Features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli data-start=\"917\" data-end=\"975\"\u003eGenuine \u003cstrong data-start=\"925\" data-end=\"975\"\u003eAtwood \/ Dometic replacement furnace component\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"978\" data-end=\"1032\"\u003e\n\u003cstrong data-start=\"978\" data-end=\"1010\"\u003eControls gas valve operation\u003c\/strong\u003e during ignition cycle\u003c\/li\u003e\n\u003cli data-start=\"1035\" data-end=\"1060\"\u003e\u003cstrong data-start=\"1035\" data-end=\"1060\"\u003e24 Volt AC valve coil\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli data-start=\"1063\" data-end=\"1109\"\u003eDesigned for \u003cstrong data-start=\"1076\" data-end=\"1109\"\u003eside outlet gas valve systems\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1112\" data-end=\"1169\"\u003eDirect replacement for worn or failed furnace valve coils\u003c\/li\u003e\n\u003cli data-start=\"1172\" data-end=\"1219\"\u003eRestores proper propane flow to burner assembly\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1221\" data-end=\"1224\"\u003e\n\u003ch2 data-section-id=\"1mnfbio\" data-start=\"1226\" data-end=\"1254\"\u003eCompatible Furnace Series\u003c\/h2\u003e\n\u003cp data-start=\"1255\" data-end=\"1348\"\u003eThis valve coil is designed for use with the following \u003cstrong data-start=\"1310\" data-end=\"1347\"\u003eAtwood Hydro Flame furnace series\u003c\/strong\u003e:\u003c\/p\u003e\n\u003cdiv class=\"TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"1350\" data-end=\"1430\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"1350\" data-end=\"1368\"\u003e\n\u003ctr data-start=\"1350\" data-end=\"1368\"\u003e\n\u003cth data-start=\"1350\" data-end=\"1368\" data-col-size=\"sm\" class=\"\"\u003eFurnace Series\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"1375\" data-end=\"1430\"\u003e\n\u003ctr data-start=\"1375\" data-end=\"1401\"\u003e\n\u003ctd data-start=\"1375\" data-end=\"1401\" data-col-size=\"sm\"\u003eAtwood 8900 III Series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1402\" data-end=\"1430\"\u003e\n\u003ctd data-start=\"1402\" data-end=\"1430\" data-col-size=\"sm\"\u003eAtwood 8900III LD Series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003chr data-start=\"1432\" data-end=\"1435\"\u003e\n\u003ch2 data-section-id=\"1a3ueyz\" data-start=\"1437\" data-end=\"1454\"\u003eSpecifications\u003c\/h2\u003e\n\u003cdiv class=\"TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"1456\" data-end=\"1684\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"1456\" data-end=\"1483\"\u003e\n\u003ctr data-start=\"1456\" data-end=\"1483\"\u003e\n\u003cth data-start=\"1456\" data-end=\"1472\" data-col-size=\"sm\" class=\"\"\u003eSpecification\u003c\/th\u003e\n\u003cth data-start=\"1472\" data-end=\"1483\" data-col-size=\"sm\" class=\"\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"1494\" data-end=\"1684\"\u003e\n\u003ctr data-start=\"1494\" data-end=\"1517\"\u003e\n\u003ctd data-start=\"1494\" data-end=\"1508\" data-col-size=\"sm\"\u003ePart Number\u003c\/td\u003e\n\u003ctd data-start=\"1508\" data-end=\"1517\" data-col-size=\"sm\"\u003e38603\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1518\" data-end=\"1555\"\u003e\n\u003ctd data-start=\"1518\" data-end=\"1533\" data-col-size=\"sm\"\u003eProduct Type\u003c\/td\u003e\n\u003ctd data-start=\"1533\" data-end=\"1555\" data-col-size=\"sm\"\u003eFurnace Valve Coil\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1556\" data-end=\"1580\"\u003e\n\u003ctd data-start=\"1556\" data-end=\"1566\" data-col-size=\"sm\"\u003eVoltage\u003c\/td\u003e\n\u003ctd data-start=\"1566\" data-end=\"1580\" data-col-size=\"sm\"\u003e24 Volt AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1581\" data-end=\"1610\"\u003e\n\u003ctd data-start=\"1581\" data-end=\"1595\" data-col-size=\"sm\"\u003eOutlet Type\u003c\/td\u003e\n\u003ctd data-start=\"1595\" data-end=\"1610\" data-col-size=\"sm\"\u003eSide Outlet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1611\" data-end=\"1648\"\u003e\n\u003ctd data-start=\"1611\" data-end=\"1625\" data-col-size=\"sm\"\u003eApplication\u003c\/td\u003e\n\u003ctd data-start=\"1625\" data-end=\"1648\" data-col-size=\"sm\"\u003eRV Propane Furnaces\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1649\" data-end=\"1684\"\u003e\n\u003ctd data-start=\"1649\" data-end=\"1664\" data-col-size=\"sm\"\u003eManufacturer\u003c\/td\u003e\n\u003ctd data-start=\"1664\" data-end=\"1684\" data-col-size=\"sm\"\u003eAtwood \/ Dometic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003chr data-start=\"1686\" data-end=\"1689\"\u003e\n\u003ch2 data-section-id=\"1cz835j\" data-start=\"1691\" data-end=\"1748\"\u003eCommon Signs Your Furnace Valve Coil Needs Replacement\u003c\/h2\u003e\n\u003cp data-start=\"1749\" data-end=\"1833\"\u003eYou may need to replace the valve coil if your furnace shows the following symptoms:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli data-start=\"1837\" data-end=\"1885\"\u003eFurnace blower runs but \u003cstrong data-start=\"1861\" data-end=\"1885\"\u003eburner never ignites\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1888\" data-end=\"1951\"\u003eFurnace attempts ignition but \u003cstrong data-start=\"1918\" data-end=\"1951\"\u003eno propane reaches the burner\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1954\" data-end=\"1999\"\u003eGas valve does not open during ignition cycle\u003c\/li\u003e\n\u003cli data-start=\"2002\" data-end=\"2058\"\u003eFurnace repeatedly \u003cstrong data-start=\"2021\" data-end=\"2058\"\u003elocks out after ignition attempts\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"2060\" data-end=\"2161\"\u003eReplacing a failed valve coil can restore normal furnace operation and proper heating inside your RV.\u003c\/p\u003e\n\u003chr data-start=\"2163\" data-end=\"2166\"\u003e\n\u003ch2 data-section-id=\"16dprsq\" data-start=\"2168\" data-end=\"2189\"\u003eInstallation Notes\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli data-start=\"2192\" data-end=\"2257\"\u003eDesigned for use with \u003cstrong data-start=\"2214\" data-end=\"2257\"\u003eAtwood 8900 III and 8900III LD furnaces\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2260\" data-end=\"2323\"\u003eAlways \u003cstrong data-start=\"2267\" data-end=\"2323\"\u003edisconnect power and propane supply before servicing\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2326\" data-end=\"2384\"\u003eInstallation may require removal of the gas valve assembly\u003c\/li\u003e\n\u003cli data-start=\"2387\" data-end=\"2470\"\u003eProfessional installation recommended if you are unfamiliar with RV furnace service\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2472\" data-end=\"2475\"\u003e\n\u003ch2 data-section-id=\"1hryhf7\" data-start=\"2477\" data-end=\"2483\"\u003eFAQ\u003c\/h2\u003e\n\u003ch3 data-section-id=\"1ojklsd\" data-start=\"2485\" data-end=\"2523\"\u003eWhat does a furnace valve coil do?\u003c\/h3\u003e\n\u003cp data-start=\"2524\" data-end=\"2692\"\u003eThe valve coil \u003cstrong data-start=\"2539\" data-end=\"2582\"\u003eelectromagnetically opens the gas valve\u003c\/strong\u003e when the furnace control board calls for heat. This allows propane to flow to the burner where it is ignited.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1c3vj38\" data-start=\"2694\" data-end=\"2735\"\u003eWhat happens if the valve coil fails?\u003c\/h3\u003e\n\u003cp data-start=\"2736\" data-end=\"2860\"\u003eIf the coil fails, the \u003cstrong data-start=\"2759\" data-end=\"2786\"\u003egas valve will not open\u003c\/strong\u003e, meaning the furnace blower may run but \u003cstrong data-start=\"2827\" data-end=\"2859\"\u003ethe burner will never ignite\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1037674\" data-start=\"2862\" data-end=\"2895\"\u003eIs this the entire gas valve?\u003c\/h3\u003e\n\u003cp data-start=\"2896\" data-end=\"2986\"\u003eNo. \u003cstrong data-start=\"2900\" data-end=\"2948\"\u003ePart 38603 is only the electrical valve coil\u003c\/strong\u003e, not the complete gas valve assembly.\u003c\/p\u003e\n\u003ch3 data-section-id=\"132bg78\" data-start=\"2988\" data-end=\"3020\"\u003eWhat furnaces use this coil?\u003c\/h3\u003e\n\u003cp data-start=\"3021\" data-end=\"3118\"\u003eIt is used on \u003cstrong data-start=\"3035\" data-end=\"3085\"\u003eAtwood 8900 III and 8900III LD series furnaces\u003c\/strong\u003e with \u003cstrong data-start=\"3091\" data-end=\"3117\"\u003eside outlet gas valves\u003c\/strong\u003e.\u003c\/p\u003e","brand":"RV Furnace Guys","offers":[{"title":"Default Title","offer_id":47895824105713,"sku":null,"price":94.95,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0784\/4941\/0289\/files\/38603.webp?v=1773348908"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0784\/4941\/0289\/collections\/Gas_valves.jpg?v=1771726482","url":"https:\/\/rvfurnaceguys.com\/collections\/gas-valves-and-burner-components-dometic.oembed","provider":"RV Furnace Guys","version":"1.0","type":"link"}