{"product_id":"dometic-atwood-31941-furnace-motor-capacitor-hydroflame","title":"Dometic \/ Atwood 31941 Furnace Motor Capacitor – HydroFlame - Special Order","description":"\u003ch2 data-start=\"211\" data-end=\"275\"\u003eDometic \/ Atwood 31941 Furnace Motor Capacitor – HydroFlame\u003c\/h2\u003e\n\u003cp data-start=\"276\" data-end=\"362\"\u003e\u003cstrong data-start=\"276\" data-end=\"332\"\u003eSpecial Order Item (7–14 Business Days for Shipping)\u003c\/strong\u003e\u003cbr data-start=\"332\" data-end=\"335\"\u003e\u003cstrong data-start=\"335\" data-end=\"362\"\u003eGenuine OEM Replacement\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"364\" data-end=\"478\"\u003e\u003cstrong data-start=\"364\" data-end=\"380\"\u003ePart Number:\u003c\/strong\u003e 31941\u003cbr data-start=\"386\" data-end=\"389\"\u003e\u003cstrong data-start=\"389\" data-end=\"406\"\u003eProduct Type:\u003c\/strong\u003e Furnace Motor Capacitor\u003cbr data-start=\"430\" data-end=\"433\"\u003e\u003cstrong data-start=\"433\" data-end=\"449\"\u003eApplication:\u003c\/strong\u003e Atwood HydroFlame Furnaces\u003c\/p\u003e\n\u003chr data-start=\"480\" data-end=\"483\"\u003e\n\u003ch2 data-start=\"485\" data-end=\"504\"\u003eProduct Overview\u003c\/h2\u003e\n\u003cp data-start=\"506\" data-end=\"657\"\u003eThe \u003cstrong data-start=\"510\" data-end=\"560\"\u003eDometic \/ Atwood 31941 Furnace Motor Capacitor\u003c\/strong\u003e is a genuine OEM replacement capacitor designed for select \u003cstrong data-start=\"620\" data-end=\"656\"\u003eAtwood HydroFlame furnace motors\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp data-start=\"659\" data-end=\"893\"\u003eThe motor capacitor provides the necessary electrical boost to help start and maintain proper motor operation. If the capacitor fails, the blower motor may hum but not start, struggle to reach full speed, or overheat during operation.\u003c\/p\u003e\n\u003cp data-start=\"895\" data-end=\"1089\"\u003eReplacing a weak or failed capacitor with OEM Part 31941 restores proper motor startup performance and consistent airflow, helping to prevent ignition issues caused by insufficient blower speed.\u003c\/p\u003e\n\u003cp data-start=\"1091\" data-end=\"1231\"\u003eManufactured to original equipment specifications, this capacitor ensures correct electrical performance and dependable long-term operation.\u003c\/p\u003e\n\u003cp data-start=\"1233\" data-end=\"1331\"\u003e\u003cstrong data-start=\"1233\" data-end=\"1249\"\u003ePlease Note:\u003c\/strong\u003e This is a \u003cem data-start=\"1260\" data-end=\"1275\"\u003eSpecial Order\u003c\/em\u003e part and typically ships within \u003cstrong data-start=\"1308\" data-end=\"1330\"\u003e7–14 business days\u003c\/strong\u003e.\u003c\/p\u003e\n\u003chr data-start=\"1333\" data-end=\"1336\"\u003e\n\u003ch2 data-start=\"1338\" data-end=\"1353\"\u003eKey Features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli data-start=\"1357\" data-end=\"1404\"\u003eGenuine OEM Dometic \/ Atwood replacement part\u003c\/li\u003e\n\u003cli data-start=\"1407\" data-end=\"1454\"\u003eDesigned for HydroFlame furnace motor systems\u003c\/li\u003e\n\u003cli data-start=\"1457\" data-end=\"1502\"\u003eSupports proper motor startup and operation\u003c\/li\u003e\n\u003cli data-start=\"1505\" data-end=\"1560\"\u003eHelps eliminate humming or non-starting blower motors\u003c\/li\u003e\n\u003cli data-start=\"1563\" data-end=\"1602\"\u003eRestores reliable airflow performance\u003c\/li\u003e\n\u003cli data-start=\"1605\" data-end=\"1644\"\u003eSpecial Order item (7–14 business days)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1646\" data-end=\"1649\"\u003e\n\u003ch2 data-start=\"1651\" data-end=\"1677\"\u003eCompatible Applications\u003c\/h2\u003e\n\u003cp data-start=\"1679\" data-end=\"1793\"\u003ePart \u003cstrong data-start=\"1684\" data-end=\"1693\"\u003e31941\u003c\/strong\u003e is compatible with select \u003cstrong data-start=\"1720\" data-end=\"1756\"\u003eAtwood HydroFlame furnace models\u003c\/strong\u003e utilizing external motor capacitors.\u003c\/p\u003e\n\u003cblockquote data-start=\"1795\" data-end=\"1893\"\u003e\n\u003cp data-start=\"1797\" data-end=\"1893\"\u003eAlways verify your furnace model and confirm it uses a separate motor capacitor before ordering.\u003c\/p\u003e\n\u003c\/blockquote\u003e\n\u003chr data-start=\"1895\" data-end=\"1898\"\u003e\n\u003ch2 data-start=\"1900\" data-end=\"1940\"\u003eCommon Symptoms of a Failed Capacitor\u003c\/h2\u003e\n\u003cp data-start=\"1942\" data-end=\"1983\"\u003eYou may need to replace the capacitor if:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli data-start=\"1987\" data-end=\"2026\"\u003eFurnace motor hums but will not start\u003c\/li\u003e\n\u003cli data-start=\"2029\" data-end=\"2059\"\u003eBlower starts intermittently\u003c\/li\u003e\n\u003cli data-start=\"2062\" data-end=\"2099\"\u003eMotor struggles to reach full speed\u003c\/li\u003e\n\u003cli data-start=\"2102\" data-end=\"2140\"\u003eFurnace trips breaker during startup\u003c\/li\u003e\n\u003cli data-start=\"2143\" data-end=\"2182\"\u003eWeak airflow causes ignition problems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"2184\" data-end=\"2268\"\u003eA failing capacitor can prevent the blower motor from reaching proper operating RPM.\u003c\/p\u003e\n\u003chr data-start=\"2270\" data-end=\"2273\"\u003e\n\u003ch2 data-start=\"2275\" data-end=\"2300\"\u003eProduct Specifications\u003c\/h2\u003e\n\u003cp data-start=\"2302\" data-end=\"2512\"\u003eManufacturer: Dometic \/ Atwood\u003cbr data-start=\"2332\" data-end=\"2335\"\u003ePart Number: 31941\u003cbr data-start=\"2353\" data-end=\"2356\"\u003eComponent: Furnace Motor Capacitor\u003cbr data-start=\"2390\" data-end=\"2393\"\u003eApplication: Select HydroFlame furnaces\u003cbr data-start=\"2432\" data-end=\"2435\"\u003eAvailability: Special Order – 7–14 Business Days\u003cbr data-start=\"2483\" data-end=\"2486\"\u003eIncludes: Capacitor only\u003c\/p\u003e\n\u003chr data-start=\"2514\" data-end=\"2517\"\u003e\n\u003ch2 data-start=\"2519\" data-end=\"2554\"\u003eFrequently Asked Questions (FAQ)\u003c\/h2\u003e\n\u003cp data-start=\"2556\" data-end=\"2680\"\u003e\u003cstrong data-start=\"2556\" data-end=\"2594\"\u003eQ: What does a motor capacitor do?\u003c\/strong\u003e\u003cbr data-start=\"2594\" data-end=\"2597\"\u003eA: It provides the electrical boost needed for the motor to start and run properly.\u003c\/p\u003e\n\u003cp data-start=\"2682\" data-end=\"2813\"\u003e\u003cstrong data-start=\"2682\" data-end=\"2725\"\u003eQ: What happens if the capacitor fails?\u003c\/strong\u003e\u003cbr data-start=\"2725\" data-end=\"2728\"\u003eA: The blower motor may hum, fail to start, or run weakly, causing ignition problems.\u003c\/p\u003e\n\u003cp data-start=\"2815\" data-end=\"2965\"\u003e\u003cstrong data-start=\"2815\" data-end=\"2855\"\u003eQ: Why is this marked Special Order?\u003c\/strong\u003e\u003cbr data-start=\"2855\" data-end=\"2858\"\u003eA: This component is not typically stocked for immediate shipment and must be ordered from the distributor.\u003c\/p\u003e\n\u003cp data-start=\"2967\" data-end=\"3063\"\u003e\u003cstrong data-start=\"2967\" data-end=\"3011\"\u003eQ: Is this an OEM Dometic \/ Atwood part?\u003c\/strong\u003e\u003cbr data-start=\"3011\" data-end=\"3014\"\u003eA: Yes. 31941 is a genuine replacement component.\u003c\/p\u003e","brand":"RV Furnace Guys","offers":[{"title":"Default Title","offer_id":47857485840625,"sku":null,"price":3.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0784\/4941\/0289\/files\/GenericDometicLogoforPartswithnoPicture_0df50546-5b2b-4943-97db-93287b7ab9a3.jpg?v=1772385097","url":"https:\/\/rvfurnaceguys.com\/products\/dometic-atwood-31941-furnace-motor-capacitor-hydroflame","provider":"RV Furnace Guys","version":"1.0","type":"link"}