{"product_id":"dometic-atwood-34696-ignition-control-circuit-board-for-xt-series-2-stage-1522-2334-2540","title":"Dometic \/ Atwood 34696 Ignition Control Circuit Board for XT Series 2-Stage 1522, 2334, 2540","description":"\u003ch1 data-start=\"0\" data-end=\"57\"\u003eDometic \/ Atwood 34696 Ignition Control Circuit Board\u003c\/h1\u003e\n\u003cp data-start=\"58\" data-end=\"104\"\u003e\u003cstrong data-start=\"58\" data-end=\"104\"\u003eReplacement For Atwood 2-Stage RV Furnaces\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"106\" data-end=\"277\"\u003e\u003cstrong data-start=\"106\" data-end=\"122\"\u003ePart Number:\u003c\/strong\u003e 34696\u003cbr data-start=\"128\" data-end=\"131\"\u003e\u003cstrong data-start=\"131\" data-end=\"148\"\u003eProduct Type:\u003c\/strong\u003e Ignition Control Circuit Board\u003cbr data-start=\"179\" data-end=\"182\"\u003e\u003cstrong data-start=\"182\" data-end=\"199\"\u003eFurnace Type:\u003c\/strong\u003e Two-Stage Electronic Ignition Furnaces\u003cbr data-start=\"238\" data-end=\"241\"\u003e\u003cstrong data-start=\"241\" data-end=\"258\"\u003eManufacturer:\u003c\/strong\u003e Dometic \/ Atwood\u003c\/p\u003e\n\u003chr data-start=\"279\" data-end=\"282\"\u003e\n\u003ch2 data-start=\"284\" data-end=\"303\"\u003eProduct Overview\u003c\/h2\u003e\n\u003cp data-start=\"305\" data-end=\"628\"\u003eThe \u003cstrong data-start=\"309\" data-end=\"366\"\u003eDometic \/ Atwood 34696 Ignition Control Circuit Board\u003c\/strong\u003e is a replacement control module designed for \u003cstrong data-start=\"412\" data-end=\"455\"\u003eAtwood HydroFlame two-stage RV furnaces\u003c\/strong\u003e. This electronic ignition board manages the furnace ignition sequence, including spark ignition, blower timing, and gas valve control to ensure safe and reliable operation.\u003c\/p\u003e\n\u003cp data-start=\"630\" data-end=\"859\"\u003eWhen the ignition board fails, the furnace may run the blower without igniting, fail to start heating cycles, or shut down prematurely. Replacing the control board restores proper furnace ignition sequencing and burner operation.\u003c\/p\u003e\n\u003cp data-start=\"861\" data-end=\"1064\"\u003eThis board is specifically engineered for \u003cstrong data-start=\"903\" data-end=\"952\"\u003eAtwood XT and other two-stage furnace systems\u003c\/strong\u003e, providing a direct replacement for the factory-installed control module. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003chr data-start=\"1066\" data-end=\"1069\"\u003e\n\u003ch2 data-start=\"1071\" data-end=\"1086\"\u003eKey Features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli data-start=\"1090\" data-end=\"1138\"\u003eOEM replacement ignition control circuit board\u003c\/li\u003e\n\u003cli data-start=\"1141\" data-end=\"1192\"\u003eDesigned for \u003cstrong data-start=\"1154\" data-end=\"1190\"\u003eAtwood two-stage furnace systems\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1195\" data-end=\"1245\"\u003eControls ignition timing and gas valve operation\u003c\/li\u003e\n\u003cli data-start=\"1248\" data-end=\"1301\"\u003eRestores proper furnace start-up and heating cycles\u003c\/li\u003e\n\u003cli data-start=\"1304\" data-end=\"1362\"\u003eDurable electronics designed for RV heating environments\u003c\/li\u003e\n\u003cli data-start=\"1365\" data-end=\"1416\"\u003eDirect replacement for the original factory board\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1418\" data-end=\"1421\"\u003e\n\u003ch2 data-start=\"1423\" data-end=\"1451\"\u003eCompatible Furnace Models\u003c\/h2\u003e\n\u003cp data-start=\"1453\" data-end=\"1513\"\u003eCompatible with the following \u003cstrong data-start=\"1483\" data-end=\"1513\"\u003eAtwood two-stage furnaces:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"1515\" data-end=\"1577\"\u003e\n\u003cli data-start=\"1515\" data-end=\"1535\"\u003e\n\u003cp data-start=\"1517\" data-end=\"1535\"\u003e\u003cstrong data-start=\"1517\" data-end=\"1535\"\u003eXT 1522 (2-Stage)\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1536\" data-end=\"1556\"\u003e\n\u003cp data-start=\"1538\" data-end=\"1556\"\u003e\u003cstrong data-start=\"1538\" data-end=\"1556\"\u003eXT 2334 (2-Stage)\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1557\" data-end=\"1577\"\u003e\n\u003cp data-start=\"1559\" data-end=\"1577\"\u003e\u003cstrong data-start=\"1559\" data-end=\"1577\"\u003eXT 2540 (2-Stage)\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"1579\" data-end=\"1630\"\u003eAlso compatible with LD variants of these furnaces.\u003c\/p\u003e\n\u003chr data-start=\"1632\" data-end=\"1635\"\u003e\n\u003ch2 data-start=\"1637\" data-end=\"1682\"\u003eCommon Symptoms of a Failed Ignition Board\u003c\/h2\u003e\n\u003cp data-start=\"1684\" data-end=\"1752\"\u003eA faulty ignition board can cause several furnace issues, including:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli data-start=\"1756\" data-end=\"1802\"\u003eFurnace blower runs but \u003cstrong data-start=\"1780\" data-end=\"1802\"\u003eno burner ignition\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1805\" data-end=\"1845\"\u003eFurnace attempts ignition but shuts down\u003c\/li\u003e\n\u003cli data-start=\"1848\" data-end=\"1875\"\u003eIntermittent heating cycles\u003c\/li\u003e\n\u003cli data-start=\"1878\" data-end=\"1930\"\u003eFurnace fails to respond to thermostat call for heat\u003c\/li\u003e\n\u003cli data-start=\"1933\" data-end=\"1957\"\u003eErratic burner operation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"1959\" data-end=\"2099\"\u003eReplacing the ignition control board is often required when the sail switch, limit switch, and gas valve test good but ignition still fails.\u003c\/p\u003e\n\u003chr data-start=\"2101\" data-end=\"2104\"\u003e\n\u003ch2 data-start=\"2106\" data-end=\"2123\"\u003eSpecifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli data-start=\"2127\" data-end=\"2151\"\u003e\n\u003cstrong data-start=\"2127\" data-end=\"2143\"\u003ePart Number:\u003c\/strong\u003e 34696\u003c\/li\u003e\n\u003cli data-start=\"2154\" data-end=\"2206\"\u003e\n\u003cstrong data-start=\"2154\" data-end=\"2173\"\u003eComponent Type:\u003c\/strong\u003e Ignition Control Circuit Board\u003c\/li\u003e\n\u003cli data-start=\"2209\" data-end=\"2255\"\u003e\n\u003cstrong data-start=\"2209\" data-end=\"2227\"\u003eIgnition Type:\u003c\/strong\u003e Electronic Ignition (DSI)\u003c\/li\u003e\n\u003cli data-start=\"2258\" data-end=\"2298\"\u003e\n\u003cstrong data-start=\"2258\" data-end=\"2275\"\u003eFurnace Type:\u003c\/strong\u003e Two-Stage RV Furnace\u003c\/li\u003e\n\u003cli data-start=\"2301\" data-end=\"2327\"\u003e\n\u003cstrong data-start=\"2301\" data-end=\"2322\"\u003eProtective Cover:\u003c\/strong\u003e No\u003c\/li\u003e\n\u003cli data-start=\"2330\" data-end=\"2375\"\u003e\n\u003cstrong data-start=\"2330\" data-end=\"2346\"\u003eApplication:\u003c\/strong\u003e Atwood HydroFlame Furnaces\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2377\" data-end=\"2380\"\u003e\n\u003ch2 data-start=\"2382\" data-end=\"2417\"\u003eFrequently Asked Questions (FAQ)\u003c\/h2\u003e\n\u003cp data-start=\"2419\" data-end=\"2603\"\u003e\u003cstrong data-start=\"2419\" data-end=\"2466\"\u003eQ: What does the ignition control board do?\u003c\/strong\u003e\u003cbr data-start=\"2466\" data-end=\"2469\"\u003eA: The ignition board controls the furnace ignition sequence, including spark ignition, blower motor timing, and gas valve activation.\u003c\/p\u003e\n\u003cp data-start=\"2605\" data-end=\"2745\"\u003e\u003cstrong data-start=\"2605\" data-end=\"2658\"\u003eQ: Is this compatible with single-stage furnaces?\u003c\/strong\u003e\u003cbr data-start=\"2658\" data-end=\"2661\"\u003eA: No. This board is designed specifically for \u003cstrong data-start=\"2708\" data-end=\"2744\"\u003eAtwood two-stage furnace systems\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp data-start=\"2747\" data-end=\"2935\"\u003e\u003cstrong data-start=\"2747\" data-end=\"2824\"\u003eQ: Can a bad ignition board cause the furnace blower to run without heat?\u003c\/strong\u003e\u003cbr data-start=\"2824\" data-end=\"2827\"\u003eA: Yes. A failed ignition board can allow the blower motor to run while preventing the burner from igniting.\u003c\/p\u003e\n\u003cp data-start=\"2937\" data-end=\"3085\"\u003e\u003cstrong data-start=\"2937\" data-end=\"2976\"\u003eQ: Is this an OEM replacement part?\u003c\/strong\u003e\u003cbr data-start=\"2976\" data-end=\"2979\"\u003eA: Yes, this is an OEM Dometic \/ Atwood replacement circuit board designed for HydroFlame furnace systems.\u003c\/p\u003e","brand":"RV Furnace Guys","offers":[{"title":"Default Title","offer_id":47864845041905,"sku":null,"price":138.95,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0784\/4941\/0289\/files\/34696.png?v=1772676020","url":"https:\/\/rvfurnaceguys.com\/products\/dometic-atwood-34696-ignition-control-circuit-board-for-xt-series-2-stage-1522-2334-2540","provider":"RV Furnace Guys","version":"1.0","type":"link"}