{"product_id":"dometic-atwood-37357-furnace-motor-8531-8535-iii-8900-iii-series","title":"Dometic \/ Atwood 37357 Furnace Motor – 8531\/8535-III \u0026 8900-III Series","description":"\u003ch2 data-start=\"164\" data-end=\"239\"\u003eDometic \/ Atwood 37357 Furnace Motor – 8531\/8535-III \u0026amp; 8900-III Series\u003c\/h2\u003e\n\u003cp data-start=\"240\" data-end=\"267\"\u003e\u003cstrong data-start=\"240\" data-end=\"267\"\u003eGenuine OEM Replacement\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"269\" data-end=\"389\"\u003e\u003cstrong data-start=\"269\" data-end=\"285\"\u003ePart Number:\u003c\/strong\u003e 37357\u003cbr data-start=\"291\" data-end=\"294\"\u003e\u003cstrong data-start=\"294\" data-end=\"311\"\u003eProduct Type:\u003c\/strong\u003e Furnace Motor\u003cbr data-start=\"325\" data-end=\"328\"\u003e\u003cstrong data-start=\"328\" data-end=\"344\"\u003eApplication:\u003c\/strong\u003e Atwood 8500-III \u0026amp; 8900-III Series Furnaces\u003c\/p\u003e\n\u003chr data-start=\"391\" data-end=\"394\"\u003e\n\u003ch2 data-start=\"396\" data-end=\"415\"\u003eProduct Overview\u003c\/h2\u003e\n\u003cp data-start=\"417\" data-end=\"576\"\u003eThe \u003cstrong data-start=\"421\" data-end=\"461\"\u003eDometic \/ Atwood 37357 Furnace Motor\u003c\/strong\u003e is a genuine OEM replacement motor designed for select \u003cstrong data-start=\"517\" data-end=\"575\"\u003eAtwood 8531-III, 8535-III and 8900-III series furnaces\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp data-start=\"578\" data-end=\"774\"\u003eThis motor drives both the combustion air wheel and the interior blower wheel, providing the airflow required for proper ignition, stable combustion, and consistent heat circulation inside the RV.\u003c\/p\u003e\n\u003cp data-start=\"776\" data-end=\"1023\"\u003eIf your furnace does not start, produces loud squealing or grinding noises, or shuts down due to weak airflow, a failing motor may be the cause. Replacing it with OEM Part 37357 restores proper airflow performance and dependable heating operation.\u003c\/p\u003e\n\u003cp data-start=\"1025\" data-end=\"1157\"\u003eManufactured to original equipment specifications, this motor ensures correct RPM, proper airflow balance, and long-term durability.\u003c\/p\u003e\n\u003chr data-start=\"1159\" data-end=\"1162\"\u003e\n\u003ch2 data-start=\"1164\" data-end=\"1179\"\u003eKey Features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli data-start=\"1183\" data-end=\"1230\"\u003eGenuine OEM Dometic \/ Atwood replacement part\u003c\/li\u003e\n\u003cli data-start=\"1233\" data-end=\"1286\"\u003eDesigned for 8531-III, 8535-III \u0026amp; 8900-III furnaces\u003c\/li\u003e\n\u003cli data-start=\"1289\" data-end=\"1341\"\u003ePowers both combustion and interior blower airflow\u003c\/li\u003e\n\u003cli data-start=\"1344\" data-end=\"1381\"\u003eRestores proper ignition sequencing\u003c\/li\u003e\n\u003cli data-start=\"1384\" data-end=\"1423\"\u003eReduces excessive vibration and noise\u003c\/li\u003e\n\u003cli data-start=\"1426\" data-end=\"1465\"\u003eBuilt to original equipment standards\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1467\" data-end=\"1470\"\u003e\n\u003ch2 data-start=\"1472\" data-end=\"1500\"\u003eCompatible Furnace Models\u003c\/h2\u003e\n\u003cp data-start=\"1502\" data-end=\"1536\"\u003ePart \u003cstrong data-start=\"1507\" data-end=\"1516\"\u003e37357\u003c\/strong\u003e is compatible with:\u003c\/p\u003e\n\u003cp data-start=\"1538\" data-end=\"1559\"\u003e\u003cstrong data-start=\"1538\" data-end=\"1557\"\u003e8500-III Series\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli data-start=\"1562\" data-end=\"1572\"\u003e8531-III\u003c\/li\u003e\n\u003cli data-start=\"1575\" data-end=\"1585\"\u003e8535-III\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"1587\" data-end=\"1608\"\u003e\u003cstrong data-start=\"1587\" data-end=\"1606\"\u003e8900-III Series\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli data-start=\"1611\" data-end=\"1621\"\u003e8935-III\u003c\/li\u003e\n\u003cli data-start=\"1624\" data-end=\"1634\"\u003e8940-III\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cblockquote data-start=\"1636\" data-end=\"1714\"\u003e\n\u003cp data-start=\"1638\" data-end=\"1714\"\u003eAlways confirm your exact furnace model from the data plate before ordering.\u003c\/p\u003e\n\u003c\/blockquote\u003e\n\u003chr data-start=\"1716\" data-end=\"1719\"\u003e\n\u003ch2 data-start=\"1721\" data-end=\"1766\"\u003eWhen Should You Replace the Furnace Motor?\u003c\/h2\u003e\n\u003cp data-start=\"1768\" data-end=\"1805\"\u003eYou may need to replace the motor if:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli data-start=\"1809\" data-end=\"1833\"\u003eFurnace fails to start\u003c\/li\u003e\n\u003cli data-start=\"1836\" data-end=\"1861\"\u003eBlower does not operate\u003c\/li\u003e\n\u003cli data-start=\"1864\" data-end=\"1910\"\u003eGrinding, humming, or squealing noises occur\u003c\/li\u003e\n\u003cli data-start=\"1913\" data-end=\"1952\"\u003eWeak airflow causes ignition shutdown\u003c\/li\u003e\n\u003cli data-start=\"1955\" data-end=\"2004\"\u003eFurnace cycles off due to airflow-related fault\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"2006\" data-end=\"2100\"\u003eA properly functioning motor is essential for both combustion safety and proper heat delivery.\u003c\/p\u003e\n\u003chr data-start=\"2102\" data-end=\"2105\"\u003e\n\u003ch2 data-start=\"2107\" data-end=\"2132\"\u003eProduct Specifications\u003c\/h2\u003e\n\u003cp data-start=\"2134\" data-end=\"2295\"\u003eManufacturer: Dometic \/ Atwood\u003cbr data-start=\"2164\" data-end=\"2167\"\u003ePart Number: 37357\u003cbr data-start=\"2185\" data-end=\"2188\"\u003eComponent: Furnace Motor\u003cbr data-start=\"2212\" data-end=\"2215\"\u003eApplication: 8531-III, 8535-III, 8935-III, 8940-III\u003cbr data-start=\"2266\" data-end=\"2269\"\u003eIncludes: Motor assembly\u003c\/p\u003e\n\u003chr data-start=\"2297\" data-end=\"2300\"\u003e\n\u003ch2 data-start=\"2302\" data-end=\"2337\"\u003eFrequently Asked Questions (FAQ)\u003c\/h2\u003e\n\u003cp data-start=\"2339\" data-end=\"2518\"\u003e\u003cstrong data-start=\"2339\" data-end=\"2388\"\u003eQ: Will this fit 8500-IV or 8900-II furnaces?\u003c\/strong\u003e\u003cbr data-start=\"2388\" data-end=\"2391\"\u003eA: This listing is specifically for 8500-III and 8900-III series models. Always verify your furnace generation before ordering.\u003c\/p\u003e\n\u003cp data-start=\"2520\" data-end=\"2630\"\u003e\u003cstrong data-start=\"2520\" data-end=\"2554\"\u003eQ: What does this motor power?\u003c\/strong\u003e\u003cbr data-start=\"2554\" data-end=\"2557\"\u003eA: It drives both the combustion air wheel and the interior blower wheel.\u003c\/p\u003e\n\u003cp data-start=\"2632\" data-end=\"2724\"\u003e\u003cstrong data-start=\"2632\" data-end=\"2659\"\u003eQ: Is this an OEM part?\u003c\/strong\u003e\u003cbr data-start=\"2659\" data-end=\"2662\"\u003eA: Yes. 37357 is a genuine Dometic \/ Atwood replacement motor.\u003c\/p\u003e\n\u003cp data-start=\"2726\" data-end=\"2872\"\u003e\u003cstrong data-start=\"2726\" data-end=\"2772\"\u003eQ: Can insufficient airflow stop ignition?\u003c\/strong\u003e\u003cbr data-start=\"2772\" data-end=\"2775\"\u003eA: Yes. If airflow is not within specification, the furnace safety system may shut down ignition.\u003c\/p\u003e","brand":"RV Furnace Guys","offers":[{"title":"Default Title","offer_id":47857480368369,"sku":null,"price":169.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0784\/4941\/0289\/files\/37357.png?v=1772382943","url":"https:\/\/rvfurnaceguys.com\/products\/dometic-atwood-37357-furnace-motor-8531-8535-iii-8900-iii-series","provider":"RV Furnace Guys","version":"1.0","type":"link"}