{"product_id":"m-c-enterprises-35132mc-furnace-limit-switch-replacement-for-atwood-rv-furnaces-8500-ii-8940","title":"M.C. Enterprises 35132MC Furnace Limit Switch – Replacement for Atwood RV Furnaces - 8500 II, 8940","description":"\u003ch1 data-section-id=\"kqdr5i\" data-start=\"285\" data-end=\"369\"\u003eM.C. Enterprises 35132MC Furnace Limit Switch – Replacement for Atwood RV Furnaces\u003c\/h1\u003e\n\u003cp data-start=\"371\" data-end=\"669\"\u003eProtect your RV furnace from overheating with the \u003cstrong data-start=\"421\" data-end=\"470\"\u003eM.C. Enterprises 35132MC Furnace Limit Switch\u003c\/strong\u003e. This replacement safety switch is designed for use in \u003cstrong data-start=\"526\" data-end=\"586\"\u003eAtwood Hydro Flame 8500-II and 8900-I series RV furnaces\u003c\/strong\u003e, helping regulate furnace temperature and prevent damage caused by excessive heat.\u003c\/p\u003e\n\u003cp data-start=\"671\" data-end=\"934\"\u003eThe limit switch continuously monitors furnace temperature during operation. If the furnace overheats due to restricted airflow or component failure, the switch \u003cstrong data-start=\"832\" data-end=\"865\"\u003einterrupts the burner circuit\u003c\/strong\u003e, shutting down the furnace to prevent damage to internal components.\u003c\/p\u003e\n\u003cp data-start=\"936\" data-end=\"1161\"\u003eIf your furnace starts but shuts down shortly after ignition or cycles on and off frequently, a faulty \u003cstrong data-start=\"1039\" data-end=\"1055\"\u003elimit switch\u003c\/strong\u003e may be the cause. Replacing the \u003cstrong data-start=\"1088\" data-end=\"1112\"\u003e35132MC limit switch\u003c\/strong\u003e can restore safe and reliable furnace operation.\u003c\/p\u003e\n\u003chr data-start=\"1163\" data-end=\"1166\"\u003e\n\u003ch2 data-section-id=\"1ma7m6t\" data-start=\"1168\" data-end=\"1183\"\u003eKey Features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli data-start=\"1187\" data-end=\"1240\"\u003e\u003cstrong data-start=\"1187\" data-end=\"1240\"\u003eM.C. Enterprises replacement furnace limit switch\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli data-start=\"1243\" data-end=\"1290\"\u003eDesigned for \u003cstrong data-start=\"1256\" data-end=\"1290\"\u003eAtwood Hydro Flame RV furnaces\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1293\" data-end=\"1326\"\u003eProtects furnace from overheating\u003c\/li\u003e\n\u003cli data-start=\"1329\" data-end=\"1374\"\u003eHelps restore proper furnace safety operation\u003c\/li\u003e\n\u003cli data-start=\"1377\" data-end=\"1439\"\u003eDurable construction for high-temperature furnace environments\u003c\/li\u003e\n\u003cli data-start=\"1442\" data-end=\"1502\"\u003eDirect replacement for worn or failed furnace limit switches\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1504\" data-end=\"1507\"\u003e\n\u003ch2 data-section-id=\"18dvupj\" data-start=\"1509\" data-end=\"1537\"\u003eCompatible Furnace Models\u003c\/h2\u003e\n\u003cp data-start=\"1539\" data-end=\"1641\"\u003eThe \u003cstrong data-start=\"1543\" data-end=\"1592\"\u003eM.C. Enterprises 35132MC Furnace Limit Switch\u003c\/strong\u003e is compatible with the following furnace models.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1au5zst\" data-start=\"1643\" data-end=\"1661\"\u003e8500-II Series\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli data-start=\"1664\" data-end=\"1673\"\u003e8516-II\u003c\/li\u003e\n\u003cli data-start=\"1676\" data-end=\"1685\"\u003e8520-II\u003c\/li\u003e\n\u003cli data-start=\"1688\" data-end=\"1697\"\u003e8525-II\u003c\/li\u003e\n\u003cli data-start=\"1700\" data-end=\"1709\"\u003e8531-II\u003c\/li\u003e\n\u003cli data-start=\"1712\" data-end=\"1721\"\u003e8535-II\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"1r789x4\" data-start=\"1723\" data-end=\"1740\"\u003e8900-I Series\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli data-start=\"1771\" data-end=\"1782\"\u003e8940-DC-I\u003c\/li\u003e\n\u003cli data-start=\"1785\" data-end=\"1796\"\u003e8940-AC-I\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"1798\" data-end=\"1854\"\u003eAlways verify your furnace model number before ordering.\u003c\/p\u003e\n\u003chr data-start=\"1856\" data-end=\"1859\"\u003e\n\u003ch2 data-section-id=\"zte05f\" data-start=\"1861\" data-end=\"1883\"\u003eWhat This Part Does\u003c\/h2\u003e\n\u003cp data-start=\"1885\" data-end=\"1988\"\u003eThe \u003cstrong data-start=\"1889\" data-end=\"1913\"\u003efurnace limit switch\u003c\/strong\u003e is a critical safety component that protects the furnace from overheating.\u003c\/p\u003e\n\u003cp data-start=\"1990\" data-end=\"2033\"\u003eDuring furnace operation, the limit switch:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli data-start=\"2038\" data-end=\"2077\"\u003eMonitors internal furnace temperature\u003c\/li\u003e\n\u003cli data-start=\"2081\" data-end=\"2109\"\u003eDetects unsafe heat levels\u003c\/li\u003e\n\u003cli data-start=\"2113\" data-end=\"2158\"\u003eShuts down the burner if overheating occurs\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"2160\" data-end=\"2241\"\u003eThis prevents damage to the furnace heat exchanger and other internal components.\u003c\/p\u003e\n\u003chr data-start=\"2243\" data-end=\"2246\"\u003e\n\u003ch2 data-section-id=\"1l2aube\" data-start=\"2248\" data-end=\"2303\"\u003eSigns Your Furnace Limit Switch May Need Replacement\u003c\/h2\u003e\n\u003cp data-start=\"2305\" data-end=\"2373\"\u003eA faulty limit switch can cause several furnace problems, including:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli data-start=\"2377\" data-end=\"2421\"\u003eRV furnace \u003cstrong data-start=\"2388\" data-end=\"2421\"\u003estarts then shuts off quickly\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2424\" data-end=\"2466\"\u003eFurnace \u003cstrong data-start=\"2432\" data-end=\"2466\"\u003eburner shuts down unexpectedly\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2469\" data-end=\"2493\"\u003eFurnace \u003cstrong data-start=\"2477\" data-end=\"2493\"\u003eshort cycles\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2496\" data-end=\"2526\"\u003eFurnace \u003cstrong data-start=\"2504\" data-end=\"2526\"\u003eoverheating issues\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2529\" data-end=\"2570\"\u003eFurnace blower runs but burner shuts down\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"2572\" data-end=\"2665\"\u003eReplacing the limit switch can often resolve \u003cstrong data-start=\"2617\" data-end=\"2664\"\u003eRV furnace overheating or shutdown problems\u003c\/strong\u003e.\u003c\/p\u003e\n\u003chr data-start=\"2667\" data-end=\"2670\"\u003e\n\u003ch2 data-section-id=\"1r8frcv\" data-start=\"2672\" data-end=\"2701\"\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003cp data-start=\"2703\" data-end=\"2845\"\u003e\u003cstrong data-start=\"2703\" data-end=\"2743\"\u003eWhat does a furnace limit switch do?\u003c\/strong\u003e\u003cbr data-start=\"2743\" data-end=\"2746\"\u003eA limit switch monitors furnace temperature and \u003cstrong data-start=\"2794\" data-end=\"2844\"\u003eshuts down the burner if the furnace overheats\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp data-start=\"2847\" data-end=\"2986\"\u003e\u003cstrong data-start=\"2847\" data-end=\"2898\"\u003eWhat happens when a furnace limit switch fails?\u003c\/strong\u003e\u003cbr data-start=\"2898\" data-end=\"2901\"\u003eThe furnace may \u003cstrong data-start=\"2917\" data-end=\"2985\"\u003eshut down during operation, short cycle, or fail to run properly\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp data-start=\"2988\" data-end=\"3214\"\u003e\u003cstrong data-start=\"2988\" data-end=\"3036\"\u003eWhich furnaces use the 35132MC limit switch?\u003c\/strong\u003e\u003cbr data-start=\"3036\" data-end=\"3039\"\u003eThis switch is used in select \u003cstrong data-start=\"3069\" data-end=\"3126\"\u003eAtwood Hydro Flame 8500-II and 8900-I series furnaces\u003c\/strong\u003e, including models 8516-II, 8520-II, 8525-II, 8531-II, 8535-II, 8935, and 8940 furnaces.\u003c\/p\u003e\n\u003chr data-start=\"3216\" data-end=\"3219\"\u003e\n\u003ch2 data-section-id=\"1n9sz8f\" data-start=\"3221\" data-end=\"3255\"\u003eWhy Buy From RVFurnaceGuys.com?\u003c\/h2\u003e\n\u003cp data-start=\"3257\" data-end=\"3510\"\u003eAt \u003cstrong data-start=\"3260\" data-end=\"3281\"\u003eRVFurnaceGuys.com\u003c\/strong\u003e, we specialize exclusively in \u003cstrong data-start=\"3312\" data-end=\"3354\"\u003eRV furnace parts and repair components\u003c\/strong\u003e. Our goal is to help RV owners and technicians diagnose heating problems quickly and find the correct replacement parts to get their furnace running again.\u003c\/p\u003e","brand":"RV Furnace Guys","offers":[{"title":"Default Title","offer_id":47879804125425,"sku":null,"price":48.95,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0784\/4941\/0289\/files\/35132MC.jpg?v=1772902077","url":"https:\/\/rvfurnaceguys.com\/products\/m-c-enterprises-35132mc-furnace-limit-switch-replacement-for-atwood-rv-furnaces-8500-ii-8940","provider":"RV Furnace Guys","version":"1.0","type":"link"}