Dometic™ / Atwood 38603 Furnace Valve Coil – 24V AC – Fits 8900 III & 8900III LD Series RV Furnaces
Dometic™ / Atwood 38603 Furnace Valve Coil – 24V AC – Fits 8900 III & 8900III LD Series RV Furnaces
Couldn't load pickup availability
Dometic™ / Atwood 38603 Furnace Valve Coil – 24V AC – Fits 8900 III & 8900III LD Series RV Furnaces
Product Overview
The Dometic / Atwood 38603 Furnace Valve Coil is a replacement electrical coil designed for use with Atwood 8900 III and 8900III LD Series RV furnaces. This 24-volt AC valve coil activates the gas valve when the furnace calls for heat, allowing propane to flow to the burner assembly for ignition.
If your furnace blower runs but no gas is reaching the burner, a failed valve coil may be preventing the gas valve from opening. Replacing the coil with the Atwood 38603 can restore proper furnace ignition and heating performance.
This replacement coil is designed for side outlet gas valve configurations used on select Atwood Hydro Flame furnace models.
Key Features
- Genuine Atwood / Dometic replacement furnace component
- Controls gas valve operation during ignition cycle
- 24 Volt AC valve coil
- Designed for side outlet gas valve systems
- Direct replacement for worn or failed furnace valve coils
- Restores proper propane flow to burner assembly
Compatible Furnace Series
This valve coil is designed for use with the following Atwood Hydro Flame furnace series:
| Furnace Series |
|---|
| Atwood 8900 III Series |
| Atwood 8900III LD Series |
Specifications
| Specification | Details |
|---|---|
| Part Number | 38603 |
| Product Type | Furnace Valve Coil |
| Voltage | 24 Volt AC |
| Outlet Type | Side Outlet |
| Application | RV Propane Furnaces |
| Manufacturer | Atwood / Dometic |
Common Signs Your Furnace Valve Coil Needs Replacement
You may need to replace the valve coil if your furnace shows the following symptoms:
- Furnace blower runs but burner never ignites
- Furnace attempts ignition but no propane reaches the burner
- Gas valve does not open during ignition cycle
- Furnace repeatedly locks out after ignition attempts
Replacing a failed valve coil can restore normal furnace operation and proper heating inside your RV.
Installation Notes
- Designed for use with Atwood 8900 III and 8900III LD furnaces
- Always disconnect power and propane supply before servicing
- Installation may require removal of the gas valve assembly
- Professional installation recommended if you are unfamiliar with RV furnace service
FAQ
What does a furnace valve coil do?
The valve coil electromagnetically opens the gas valve when the furnace control board calls for heat. This allows propane to flow to the burner where it is ignited.
What happens if the valve coil fails?
If the coil fails, the gas valve will not open, meaning the furnace blower may run but the burner will never ignite.
Is this the entire gas valve?
No. Part 38603 is only the electrical valve coil, not the complete gas valve assembly.
What furnaces use this coil?
It is used on Atwood 8900 III and 8900III LD series furnaces with side outlet gas valves.
Share